Leaking 50 gal electric water heater. This tank is storage for the solar water heating system. The customer has declined replacement. Put tank into bypass. Shut off the solar system. Tank must be replaced to use solar system.
Adjusted trip lever in hall bath toilet. Tested good. Flushed multiple times no problems found.
Found clean out cover screw to be missing leaving hole directly to waste line, replaced screw. Tested good no leaks. No smell.
Opened wall in living room to locate leak. Found leak from 2†waste line from second floor hall bath. Removed cracked fitting and replaced with new. Tested good. A.B.S. Not responsible for wall repair.
Performed post install audit. Found unit operating to specs. Addressed concerns.
Performed diagnostic found bad VAD replaced. Unit cooling at this time.
Performed diagnostic found bad directional valve. Need to replace. Has parts warranty. $2200 for refrigerant, labor. 6 month warranty.
Performed diagnostic found bad VAD replaced unit cooling at this time. Exaust motor drawing good amps at this time.
Diagnostic on unit found compressor locked up cooled off with water 5 times. Over amped and overheated due to being locked up. While doing paperwork unit started working. Keep eye on unit and call if it happens again.
Performedmed diagnostic found bad VAD and factory start kit.
Performed diagnostic found blower door sitting nex to unit. Put door on cooling at this time.
Performed acm tuneup found bad Exhaust motor and VAD. ON south unit. Replaced on bronze package.
Performed ACM tune up found bad VAD and dirty coil cleaned coil replaced VAD. tightend loose connections.