Job Locations
for searchlight, nv

Christian V.

Christian V. Job Checkin

remove and replace existin m/h propane 40 gallon water heater and bring up to code. Removed existing heater and installed 40 gallon Rheem converted to LP with conversion kit. Added shut off valve, drip leg and expansion tank to bring up to code. Tested all connection and filled heater. No leaks. Tank firing and heating. Collected payment. Customer would like invoice mailed to address as she doesn’t use internet. No issues to report. Customer satisfied with todays service.


glittrell@ambientedge.com

glittrell@ambientedge.com Job Checkin

Upon arrival I found the dual run capacitor rated for 70/7.5 and testing 0/0 and puffed up. After replacing the capacitor the unit began running like normal. Recommend continued maintenance. P.O. Box 222 searchlight 89406


Maykol F.

Maykol F. Job Checkin

Arrived on site. Performed all necessary work to replace evaporator coil. Put system into vacuum down to 350 microns. Added R410A refrigerant into system. Tested system after repair and found the unit running and cooling as designed. All work is complete.


Larry G.

Larry G. Job Checkin

Arrived on site spoke to Duncan went ahead and replace evaporator coil. Unit is not running and cooling the house as it should. We tested the unit to make sure there was no leaks. Brought microns down to 350. Customer is happy that we got the unit running and cooling.


Jaden S.

Jaden S. Job Checkin

Arrived on site, checked in with customer and spoke of any issues regarding the hvac system, one at this time was the condenser wouldn’t turn on with the blower, after inspection it was found that that was just normal operation with a 5 minute delay, preformed entire maintenance checklist and cleaned outdoor coil, vacuumed out entire condensing unit taking out leaves and dirt, checked out with customer and got signatures.


Jaden S.

Jaden S. Job Checkin

Topped off system and added ezseal to try and get a temp fix until part arrives, no charge per Brandi


Maykol F.

Maykol F. Job Checkin

Arrived on site unit was not cooling they just had added refrigerant in fix a leak yeah universe steel dropping refrigerant levels check the evaporator coil noticed that there was a stain on the coil decided to throw some bubbles coil started bubbling call the office they told me that the universe in JB a a warranty I did the warranty paper and the parts order sheet Miss Barry said that they were going to call the customer in the day to find out when could they get the part that they need other than that no further quotes necessary


jecheverria@ambientedge.com

jecheverria@ambientedge.com Job Checkin

Arrived to customers home, ask if she had any questions about the unit. Proceeded with the maintenance, inspected and cleaned two mini split head unit and condenser. Units are running as designed, no issues to report.


Christopher W.

Christopher W. Job Checkin

Direct change out of packaged heat pump. Transition to existing ductwork. Removal and disposal of old equipment. Reconnected existing electrical and install new disconnect. Set equipment on weatherproof pad. 10 year parts warranty two year labor warranty. VIP plan discount applied. Includes county required permit.


Jaden S.

Jaden S. Job Checkin

Arrived on site. Performed all necessary work to replace the compressor. I begun recovery, and disassembled compressor along with filter drier. Replaced older compressor with new compressor & new filter drier. Performed a nitrogen decay test on unit. I vacuumed out unit, and added refrigerant charge to manufacturer specifications. Tested for pressures and found unit was operational upon completion of repair. All work is complete.


dhoneycutt@ambientedge.com

dhoneycutt@ambientedge.com Job Checkin

Arrived at customer's residence and found system completely out of refrigerant. During leak inspection, found rubbed out compressor and CFM wiring on liquid lineset. Repaired wiring, checked condition of both motors, repaired the lineset leak, replaced filter drier, pressure tested, pulled a deep vacuum, and recharged 10.5 lb of R-410A into the system. Strapped all adjacent wiring in order to prevent further rubouts. Work completed. Service warranty.


Jaden S.

Jaden S. Job Checkin

Arrived on site, checked in with customer and begun recovery, disassembled compressor along with filter dryer, replaced old compressor with new and old dryer with new, nitrogen decay tested unit, vacuumed out unit, and factory charged up unit, tested for pressures and unit was operational upon completion of repair, checked out.


jmccarty@ambientedge.com

jmccarty@ambientedge.com Job Checkin

Arrived on site and checked in with customer. Found system nearly flat with compressor still running. Compressor was hot and emitting a pronounced pulsating “thrumming” sound. Located leak and found it on equalizing tube that was repaired in May 2022. Recovered small amount of remaining refrigerant and repaired leak. Pressure tested, vacuumed system, recharged with R410A. System now operates properly in terms of pressures and amps, but the compressor now produces a rattling sound, leading to believe there is internal damage. Possibly due to oil loss or running with little to no charge on multiple leak occurrences, but could not be confirmed. Submitting parts order sheet for compressor under warranty as the current one, though currently not displaying measurable issue, can no longer be trusted to continue to function long term. System operating properly at the end of the service call. Service warranty on repair dating to 5/2022.


Spencer R.

Spencer R. Job Checkin

Arrived on site. Performed all necessary work to replace TXV. Removed older TXV and brazed in new one while running nitrogen. Pressure tested with nitrogen and micro bubbles. System held test for 15 minutes. Pulled vacuum to nearly 500 microns. Recharged with 10 pounds of R-410 refrigerant. Tested operation and confirmed unit is currently working as designed with no more leaks. All work is complete.


Spencer R.

Spencer R. Job Checkin

Arrived on site to replace TXV under warranty. Removed txv and brazed in new one while running nitrogen. Pressure test with nitrogen and micro bubbles. Held test for 15minutes. Pulled vacuum to nearly 500 microns. Recharged with 10 pounds of 410 refrigerant. Tested operation and confirmed unit is currently working properly and has no leaks. All work is complete