not good service

We've had problems from the beginning. Every time they come out to fix something, it's a different story as to what is wrong. They don't fix it. They quote regulations and not what we requested from them to replace our broken unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

What a nice guy!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Sat, service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Second call

We appear to have somewhat of a solution. Will monitor and let you know if the problem is resolved.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing

Great service very fast and efficient, and surprisingly was here early.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very disappointed with your quality of service.

two of your technicians, one two separate serviced our AC unit for a drip problem. Even though they both assured us that the problem was fixed it is not. Water is still dripping from the unit and causing damage to the ceiling tile.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service Very Knowledgable

Contacted Bay Area for a second opinion and found that the problem originally diagnosed by another company was not the problem at all.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service and Awesome Price

Excellent job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for brooksville, fl

Cliff P.

Cliff P. Job Checkin

heating element need replacement, parts Order request form send it to proper channel , call client when part available


Cliff P.

Cliff P. Job Checkin

heating element need replacement, parts Order request form send it to proper channel , call client when part available


Cliff P.

Cliff P. Job Checkin

Need to return and replace control board, system is currently down, call client when part is available


Cliff P.

Cliff P. Job Checkin

Need to return and replace control board, system is currently down, call client when part is available


Cliff P.

Cliff P. Job Checkin

Service call completed, check system operations, system is leaking from the evap coil, system is over 9 years old, options and recommendations are made and send to the email on file , financing is available call to schedule a installation date


Cliff P.

Cliff P. Job Checkin

Service call completed, check system operations, system is leaking from the evap coil, system is over 9 years old, options and recommendations are made and send to the email on file , financing is available call to schedule a installation date


Cliff P.

Cliff P. Job Checkin

Found blown fuse 5 amp. Checked for a short and did not find at this time. System no working properly.


Cliff P.

Cliff P. Job Checkin

Found blown fuse 5 amp. Checked for a short and did not find at this time. System no working properly.


Jeff M.

Jeff M. Job Checkin

annual ac tuneup. I checked all operations of system and were good. I checked smp draw,static pressure, and temp sp,its. I waxed outdoor unit. I cleaned both coils and flushed drainline multiple times. I see no problems at this time.


Cliff P.

Cliff P. Job Checkin

Service call completed, upon arrival conderser unit not getting 240v , reset 40 amp cuttler hammer outdoor breaker several times, breaker seems hard to throw the pole, replace with a 40 amp breaker, check Voltage, advised client system condition and may happens again since the compressor is pulling higher energy consumption, no charge at this time since system was working upon arrival of the morning service, system replacement is on scheduled already


Cliff P.

Cliff P. Job Checkin

Service call completed, upon arrival conderser unit not getting 240v , reset 40 amp cuttler hammer outdoor breaker several times, breaker seems hard to throw the pole, replace with a 40 amp breaker, check Voltage, advised client system condition and may happens again since the compressor is pulling higher energy consumption, no charge at this time since system was working upon arrival of the morning service, system replacement is on scheduled already


Glen H.

Glen H. Job Checkin

Contactor points were not meshing properly, tested system and replaced


Jeff M.

Jeff M. Job Checkin

pull nuclear evaporator coil and pressure wash Pull Airbender a install new top on the stand and refine with duct board 40"×40" top 2 people 4 hrs already have to pull coil to clean the coil


Pete C.

Pete C. Job Checkin

System working good quoted to put in supply duct 10x6 Cover suction line seal line cover


Pete C.

Pete C. Job Checkin

Unit has ecu not connected to condenser but connected to water tank. Will need to remove water lines and old ecu from wall. Drain line buried had to dig it out Put spray foam in top of line cover cover was open. Need to come back after closing to do repairs Redo drain line outside