8021 W. Gulf to Lake Hwy
Crystal River , FL 34429
352 795 2665

Local Reviews
for dunedin, fl

Rated 5.0 out of 5 stars based on 14 customer reviews

Finally!

Glen was the most knowledgeable of all your great techs I have dealt with. I’ve got my fingers crossed that the problem is finally fixed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Once again, I’m very satisfied with the service I’ve received from Bay Area A/C!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional, proficient service

We have had an ongoing refrigerant leak in our air conditioner, one that is very hard to pinpoint. Jeff has done a very diligent job of trying to locate it, and we’re both hoping it’s finally fixed. As a retired tradesman who has extensive refrigeration experience myself, I really appreciate his commitment and skills.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service I Trust

Through no fault of his, this is the second time Jeff has had to service our A/C this year. Both times he has demonstrated conscientious professionalism in approaching and taking care of the problems. He has consistently explained what was wrong and his solution clearly. As a retired service technician myself, I recognize good service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service at a reasonable price!

I got a quick response to my problem. The technician, Jeff, was quite knowledgeable and personable, solving the problem quickly, explaining it clearly, and all at a fair and reasonable price.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Cliff was very knowledgeable and did a great job explaining what was going on.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledge and friendly

He was very professional and polite.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A great employee

We always ask for David

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Arrived within time limits, polite, clean and fast.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always Great

We have had David for 4 or 5 years, I ask for Dave ! He always is enjoyable to have for our service work. I will expect to have him as long as we live here.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dunedin, fl

Cliff P.

Cliff P. Job Checkin

10 year parts and 1 year labor warranty


Cliff P.

Cliff P. Job Checkin

10 year parts and 1 year labor warranty


Cliff P.

Cliff P. Job Checkin

SYSTEM NUMBER 5 Replaced shorted dual run capacitor and cooled down compressor that was over heated. Restarted and tested cooling.


Cliff P.

Cliff P. Job Checkin

SYSTEM NUMBER 5 Replaced shorted dual run capacitor and cooled down compressor that was over heated. Restarted and tested cooling.


Glen H.

Glen H. Job Checkin

#3 rooftop unit on SE corner Evaporator 50% frozen solid, blower belt flopping. Sprayed rust blaster on adjusting nut. Unit suspect of low refrigerant = refrigerant leak Return when unit thawed to confirm, possible leak search


Cliff P.

Cliff P. Job Checkin

Customer canceled at the door.


Cliff P.

Cliff P. Job Checkin

Customer canceled at the door.


Jeff M.

Jeff M. Job Checkin

upon I removed 3/4 hp module and installed my temp module. I collected 200.00 per Dale to be credited to new equipment. It is cooling at this time.


Cliff P.

Cliff P. Job Checkin

Bryant 288ANA036000DBAA. 1709E21021 Replaced outdoor defrost board that had signs of corrosion and burn marks. Rebooted and ran install. System is running now. Customer supplied defrost board. May need to replace model plug Recall.


Cliff P.

Cliff P. Job Checkin

Bryant 288ANA036000DBAA. 1709E21021 Replaced outdoor defrost board that had signs of corrosion and burn marks. Rebooted and ran install. System is running now. Customer supplied defrost board. May need to replace model plug Recall.


Glen H.

Glen H. Job Checkin

Leak search, found leak hot gas connection to S/O valve (confirmed with soap bubbl) 125psi standing in system, removed refrigerant, solder repair at leak, pressure test to 325, changed drier, evacuation, restart & recharge with virgin 410, recorded stats


Cliff P.

Cliff P. Job Checkin

Replaced contactor with pitted contacts . Restarted and tested cooling. Checked freon level


Cliff P.

Cliff P. Job Checkin

Replaced contactor with pitted contacts . Restarted and tested cooling. Checked freon level


Cliff P.

Cliff P. Job Checkin

Found that the blower motor is fading in and out. Replaced the blower motor and tested the operation.


Cliff P.

Cliff P. Job Checkin

Found that the blower motor is fading in and out. Replaced the blower motor and tested the operation.