Found the system low on r22. Added 2 lbs of r22. The air handler is 15 years old and the condenser is 10 years old. The system is in poor condition and I'd recommend having it replaced. Leaving pressures 68/210
Found two PVC fittings loose causing water to drip. Removed some pipe and repaired the drain line. We will warranty this repair for two years.
Found the system didn't have any refrigerant in it. Pressure tested to 150 PSI which held for 20 minutes. Pulled the system down into a vacuum and charged the system. 12 lbs total added.
Completed the maintenance inspection. Recommend an Ultra Violet system
Marked the heater size and breaker on the air handler and circled the ampage requirement on the factory label. Sealed the bottom of the supply plenum and foamed the hole around the drain line outside. Uploaded images. If the inspector wants to come back out the homeowner said we need to meet with him.
Needs 2 14" by 14" washable filters made up and a 18" by 24" washable filter.
Found the outdoor disconnect removed from the box.
Found stat by and not energizing reversing valve. Ordered new and going to pick up to get taken care of. Installed and tested new TCNHP01A. System working properly
Found that the heater relaies weren't allowing the heater to come on. Will need to order the parts and return with the customers approval. Labor repair $120.00
10 year parts and 1 year labor warranty
Completed the maintenance inspection. The capacitor is reading low. 61/70 over 2.6/5
Found that the system has a bad blower module. New blower motor quoted.