Matt  C.

Matt C. Job Checkin

Found the system low on r410a. Added three lbs and brought the charge to 11 degree Subcooling


Cliff P.

Cliff P. Job Checkin

Completed the maintenance inspection.


Cliff P.

Cliff P. Job Checkin

Cleaned drain line took off panel to coil cleaned pan out and put dawn dish liquid in drain line. Made sure unit is draining. Also customer wanted silver contract


Don K.

Don K. Job Checkin

Called customer on phone, customer just needs estimate on doing away with duct in the garage and to check Master run,and quote repairs if needed


Cliff P.

Cliff P. Job Checkin

Wasn't able to remove the old line set. Rediagnosed the system to find that the copper line set and evaporator coil has no leak at all. Leaving pressures 158 / 325 21 degree superheat 2 year bay area labor warranty.


Cliff P.

Cliff P. Job Checkin

Customer canceled


Cliff P.

Cliff P. Job Checkin

Found drain backed up. Cleaned, flushed and treated drain. System now draining properly. System cooling


Cliff P.

Cliff P. Job Checkin

Cleaned drain major clog


Cliff P.

Cliff P. Job Checkin

Upon arrival found compressor not running. Located shorted dual run capacitor. Replaced capacitor and restarted cooling. Checked refrigerant level 40+5 dual run capacitor.


Cliff P.

Cliff P. Job Checkin

Found that the interior duct work is leaking air within the walls of the manufactured home.the vents are condensating.


Cliff P.

Cliff P. Job Checkin

Found defrost board not sending voltage to run fan motor. Bypassed defrost board to get system working.. Cost to replace board is $540. Customer is going to wait on repair at this time.


Cliff P.

Cliff P. Job Checkin

Found a clogg within the drain line. Removed the piping and cleared the clogg. Treated, flushed, and tested the drain system. Warranty No Charge


Cliff P.

Cliff P. Job Checkin

This is An Estimate to Install A New Carrier 15 seer Package Unit Heat Pump.


Cliff P.

Cliff P. Job Checkin

found water in emergency overflow switch causing system to shut down. Cleaned out drain with shop vac. Restarted and tested cooling and drain line.


Cliff P.

Cliff P. Job Checkin

Spoke to customer and answered questions about yesterday's work.