7908 Rutillio Ct
New Port Richey, FL 34653
(727) 375-2665

Local Reviews
for citrus springs, fl

Rated 4.9 out of 5 stars based on 86 customer reviews

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific service

Every technician and representative of Bay Area Air Conditioning that we dealt with were extremely polite and knowledgeable. All of our concerns and questions were answered and each one we had contact with made sure we understood everything.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service once again!

As long as you continue to provide great technical services at reasonable prices I will continue to remain a customer and recommend you to my friends and family.

  • Overall Experience
  • Quality
  • Price
  • Convenience

as always we were very satisfied. thats why we continue to call

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast & great service

Fix problem as soon as they could. Part came in next day

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Service and a very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always on Time

We just had our annual tune-up for our air-conditioning and everything went smoothly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

My neighbor told me about Bay air the service was excellent I want to thank Shaun for all this help very knowledgeable courteous respectful in the near future if I have a problem I am going to request to send him puts me at ease. I hope Bay air recognizes all their employees once again thank you Shaun

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great,Honest,Service!

I always appreciate meeting with servicemen from your company. They are always honest and accurate with their work that they do!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for citrus springs, fl

Cliff P.

Cliff P. Job Checkin

Installed fused disconnect, check system charge, padded PVC coupler to cover hole in drain line. Everything checked out and is ready for inspection


Cliff P.

Cliff P. Job Checkin

This is an estimate for a 14 Seer Bryant single stage 2 ton heat pump. Estimate includes all labor materials permitting fees new hurricane pad new thermostat a return in the center of the house and a 10-year parts and labor warranty


Cliff P.

Cliff P. Job Checkin

Checked out appliances and panel breaker size and gave info to David to find out if the install is in good shape. Everything checks out for the installation tomorrow.


Cliff P.

Cliff P. Job Checkin

Repair shorted out low voltage wire to overflow kill switch and repaired thermostat wire at outdoor unit. Changed out a week run capacitor for the blower motor and cleared the drain line and treated the drain pan with an antimicrobial agent. Replaced blown fuse caused by low voltage short. Outdoor capacitor is fine. Compressor is pulling High amps 10.6/15.4 and fan amp draw is 1.2/1.3, amp draw could possibly be reduced with cleaner coils. Recommend a checkup. System is running, cooling, and draining fine.


Cliff P.

Cliff P. Job Checkin

Stop a customer about her needs wants and concerns in regards to a new air conditioning system. Filled out job replacement sheet info. Built estimates and discuss them with the homeowner. Emailed estimates to customer. Customer will call in to speak with Accounting in regards to financing


Cliff P.

Cliff P. Job Checkin

Sound system not communicating with indoor and outdoor unit. Tested the DC voltage from the A and B terminals on the fan board and it was below 3 volts. This indicated a failing board. Replaced the board which is now showing 4.2 volts. Ran and tested system which is communicating with all components in the system. Fan board has a two-year part and labor warranty


Cliff P.

Cliff P. Job Checkin

Compressor is shorted to ground and causing breaker to trip. Spoke with homeowner and check for warranty. Compressor is covered under a part warranty and the customer would like us to order a new one and replace it ASAP. Part has been ordered and customer has been informed of the price. Customer will call to the office when she gets home to pay.


Cliff P.

Cliff P. Job Checkin

Fan is pulling .8/1.1 amps and there's nothing impeding the fan rotation of anything wrapped around the shaft. Customer informed me the sound stopped yesterday after he powered down the unit and turned it back on. Possibility something got caught in the fan blade and caused the sound but there's nothing wrong with the unit at this point. Unit is running fine.


Cliff P.

Cliff P. Job Checkin

All capacitor are in good shape. Compressor is pulling 7.6/18.3 amps and the fan is pulling .6/.7 amps. Both are in good shape. Condensing coil is nice and clean. Evaporator coil is a bit dirty but not hindering cooling. Could use a coil pull and clean to optimize performance and improve dehumidification. One coil pull and clean and good filter maintenance will ensure evaporator coil stays clean. Left estimate for this procedure. Refrigerant circuit is in good shape with the appropriate charge. Overall unit seems to be in very good shape. Unit is running, cooling, and draining fine.


Cliff P.

Cliff P. Job Checkin

Dugout drain line out of ground, built it up with some scrap PVC, clear drain line and drain pan and treated with Dawn dish soap. Unit is running and draining fine.


Cliff P.

Cliff P. Job Checkin

Inspected whole system found compressor amp draw at 8 / 16 amps with a condensing fan amp draw of .8/ 1.4. Check to see if drain line was clogged it is not and unit is draining fine. Refrigerant circuit pressures temperatures superheat and subcooling all look good. Compressor windings ohm readings are good. Unit is running Cooling and draining fine at this time. Left estimate for system did to age and condition. Option to add extended labor warranty on unit is recommended.


Cliff P.

Cliff P. Job Checkin

Cleaned both units indoor and outdoor coils.


Cliff P.

Cliff P. Job Checkin

Includes 10 years part and labor warranty. See details


Cliff P.

Cliff P. Job Checkin

This is An Estimate to Install A New Carrier 14 seer Heat Pump.


Cliff P.

Cliff P. Job Checkin

System has a compressor that is shorted to ground. Leaving estimates for replacement of compressor as well as the whole system.