7908 Rutillio Ct
New Port Richey, FL 34653
(727) 375-2665

Local Reviews
for inglis, fl

Rated 5.0 out of 5 stars based on 51 customer reviews

Very knowledgeable tech

The tech arrived within 2 hours of my call, i could not believe it. The problem with our HVAC unit was diagnosed very quickly, repaired and with professionalism. Can't thank them enough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very good service and very nice service men

I loved the service men that you sent, they were both very polite

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good work and Friendly tech.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Above and Beyond

My guy Rob continues to provide outstanding service, with some entertainment on the side!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Mrs

As ALWAYS, courteous and professional from Mr Hirsch

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Rob Hirsch is an outstanding service tech. He is always professional knowledgeable and very friendly. A real asset to Bay Area

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work as always, very professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work as always, very professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super service

Rob is a great service person, very knowledgeable .

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Service Tech very professional, polite and friendly, answered all our questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

These folks at Bay Area did a great job getting our a/c unit installed in a very timely manner. Rob Hirsch was very helpful getting us quickly up and running with a new Carrier a/c unit. Hats off to all involved in the great service by all at Bay Area! Thanks, Benjamin Blackson

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great personality. Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. excellent equipment

We specifically requested Rob as the servicing technician. He is so knowledgeable and efficient. A great asset for your company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for inglis, fl

Tyler H.

Tyler H. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running and draining fine.


Carolyn R.

Carolyn R. Job Checkin

14 SEER CARRIER PACKAGED STRAIGHT COOL WITH ELECTRIC HEAT. NEW DUCTWORK UNDER HOUSE. 10 YEAR PART AND LABOR WARRANTY.


Carolyn R.

Carolyn R. Job Checkin

This is An Estimate to Install A New Carrier 14.5 seer Package Unit Heat Pump. This estimate includes all materials, labor, a new thermostat, and a 10 year parts and labor warranty.


Tyler H.

Tyler H. Job Checkin

This is an estimate for a coil pull and clean s well as a total system cleaning and check. This includes a pump down of refrigerant into condensing unit, cutting out the evaporator coil, cleaning it until like new, installing the coil, changing the filter drier, sweeping the system with nitrogen and pulling a deep vacuum to ensure there is no moisture or contaminants. Cleaning the condensing coil, drain line, drain pan, blower wheel and housing. Then checking the system functions to ensure there are no problems with any components or the systems charge.


Tyler H.

Tyler H. Job Checkin

Determined thermostat wasnt sending signals due to corroded batteries. Spoke with customer who authorized changing it out for new. Tested system in heating and cooling, which are running fine. Customer wanted to sign up for silver contract. Customer will call and schedule tune up.


Tyler H.

Tyler H. Job Checkin

Found unit with no running blower. System needs a new one. Found questionable wiring for two capacitors wired in series for compressor and condensing fan. Tested both, one of which is completely bad. Took it the oversized one and put in a new appropriately sized capacitor. Ran system and found compressor running load amps to be 17.5/14.5. Condensing fan motor amperage is 1.5/1.9. Compressor will definitely fail while working hard on hot days. System ductwork is also undersized for the tonnage of the unit. Due to condition of the unit recommend replacement over repair. Leaving estimates for replacement and repairs.


Tyler H.

Tyler H. Job Checkin

Found the float switch tripped at time of arrival. Cleaned the drain line and drain pan and treated both with antimicrobial agents. System is cooling and draining fine. Bill has been emailed.


Jose R.

Jose R. Job Checkin

Upon arrival turned unit on at disconnect. System kicked on and ran in cooling mode. System is running normally at this time.


Tyler H.

Tyler H. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Found blower capacitor to be weak, customer authorized changing for new. Unit is running fine.


Jose R.

Jose R. Job Checkin

Replaced OD Fan motor. Put new 40/5 dual run cap. Unit is running at this time


Tyler H.

Tyler H. Job Checkin

Cleaned indoor, outdoor, and humidifier coils. Cleaned drain line from the humidifier through under the slab and cleaned the drain pan and treated all with an antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Tyler H.

Tyler H. Job Checkin

Customer expressed concern about mildew and what appears to be water damage on interior wall of unconditional room. This wall is made of concrete. Found marginally small air seepage where plenum attaches to top of the unit, however nothing that should cause this problem. Spoke with Don about the situation and he recommended I take video and pictures of everything to show management and ask their opinion on what we can do. Outside of these problems the condensing unit coil is cashed with debris from an outdoor drier vent. The evaporator coil needs to be cleaned and cannot be done any other way than a coil pull and clean. The blower wheel is quite dirty and needs to be cleaned as well. Will leave estimate for all of this and will get back with customer about water/mildew spots after speaking with management.


Tyler H.

Tyler H. Job Checkin

System not responding to anything at time of arrival. Looked up manual and began trouble shooting process. Replaced batteries with new, reset controller, and put the unit in failure recall mode. Attempted to follow along with instructions with no success. Called Rob and spoke with him about it. He recommended visually checking the board and the compressor windings. Took outdoor unit apart after pulling disconnect and did so, with no apparent burns and with compressor windings all matching up. Restored power and unit began working. Asked customer to keep an eye on it and call us back if the unit fails to heat or cool again. Unit is running fine.


Tyler H.

Tyler H. Job Checkin

Spoke with customer about other heating and cooling options. Gave an estimate for a straight cool system. Customer will contact the office in regards to financing.


Jose R.

Jose R. Job Checkin

Found unit fuse popped at air handler. Traced short back to thermostat. in the middle of diagnostics, breaker no longer was supplying high voltage coming out. By passed breaker, by passed thermostat. Unit running in heating and cooling . Advised to replaced thermostat. Ordered. New 60 amp breaker.