Very knowledgeable tech

The tech arrived within 2 hours of my call, i could not believe it. The problem with our HVAC unit was diagnosed very quickly, repaired and with professionalism. Can't thank them enough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very good service and very nice service men

I loved the service men that you sent, they were both very polite

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good work and Friendly tech.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Above and Beyond

My guy Rob continues to provide outstanding service, with some entertainment on the side!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Mrs

As ALWAYS, courteous and professional from Mr Hirsch

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Rob Hirsch is an outstanding service tech. He is always professional knowledgeable and very friendly. A real asset to Bay Area

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work as always, very professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work as always, very professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super service

Rob is a great service person, very knowledgeable .

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Service Tech very professional, polite and friendly, answered all our questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

These folks at Bay Area did a great job getting our a/c unit installed in a very timely manner. Rob Hirsch was very helpful getting us quickly up and running with a new Carrier a/c unit. Hats off to all involved in the great service by all at Bay Area! Thanks, Benjamin Blackson

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great personality. Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. excellent equipment

We specifically requested Rob as the servicing technician. He is so knowledgeable and efficient. A great asset for your company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for inglis, fl

Jose R.

Jose R. Job Checkin

Found unit fuse popped at air handler. Traced short back to thermostat. in the middle of diagnostics, breaker no longer was supplying high voltage coming out. By passed breaker, by passed thermostat. Unit running in heating and cooling . Advised to replaced thermostat. Ordered. New 60 amp breaker.


Jose R.

Jose R. Job Checkin

Customer concern was unit not blowing hot air. Customer said steam was coming from unit and decided to shut it off. Explained to customer unit was in defrost mode. Explained what happens in defrost mode. Unit is blowing 95⁰ air at this time. Puddle of water around package unit. Checked all electrical connections, amp draws and refrigerant levels. Unit is running at this time.


Jose R.

Jose R. Job Checkin

Customer concern was OD Fan was not Running and blower motor would not shut off. OD fan went off on thermal overload, OD fan is over amping. Found bad blower module, Blower motor would not shut off even in the off position. Quoted customer for module only. Customer wants to replace OD Fan. Ordered new OD Fan motor. Customer will also want module replaced at a later time.


Carolyn R.

Carolyn R. Job Checkin

10 year parts and 1 year labor warranty


Carolyn R.

Carolyn R. Job Checkin

Called customer, wants us to come out when we can. not available wednesday or thursday, Need to see David before rescheduling.


Carolyn R.

Carolyn R. Job Checkin

Customer complaint was unit was not cooling. Upon arrival thermostat was replaced. check wiring on thermostat, fixed two misplaced wire. Found new thermostat to be bad. Put old thermostat back on the wall, unit was running normally. Ran system in both modes, blowing 53⁰ air out of supplies. Checked all electrical connections, amp draws and refrigerant levels. Bill sent through email.


Carolyn R.

Carolyn R. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Carolyn R.

Carolyn R. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Cliff P.

Cliff P. Job Checkin

Cleaned indoor and outdoor coils as well as drain line and treated drain pan with antimicrobial agent. Checked all electrical connections and amp draws as well as refrigerant circuit pressures and temperatures. Unit is running fine.


Cliff P.

Cliff P. Job Checkin

Replaced blower control board and rewired system to be compatible with new board. Tested system operations and verified blower will come on and turn off when there is no call for fan. Tested system operation, system is in good operating condition at this time.


Cliff P.

Cliff P. Job Checkin

Found indoor blower running constantly. Found bad blower relay, tested for continuity across common and NO pins. Relay stuck closed.


Cliff P.

Cliff P. Job Checkin

CUSTOMER INSTALLED THERMOSTAT, CONNECTED COMMON WIRE TO B CIRCUIT CAUSIJV TRANSFORMER TO BLOW WHEN UNIT WENT INTO HEAT. REPLACED EITH 40VA TRANSFORMER CHECKED UNIT IN HEATING AND COOLING, UNIT IS OPERATING NORMALLY AT THIS TIME. SETUP THERMOSTAT PER CUSTOMER MANUAL.


Cliff P.

Cliff P. Job Checkin

Found short and thermostat wire on the orange circuit. Swap wires to the black wire to use as reversing valve in system is operating normally


Cliff P.

Cliff P. Job Checkin

This is for the oldest of the three units. The 3 train 2.5 ton R22 system. Unit did come up and run but outdoor fan motor bearings are bad. An invoice quoted price for new outdoor fan motor. Recommend possible replacement of system over repair due to age of system


Cliff P.

Cliff P. Job Checkin

Did evaluation on system. System is holding charge and superheat was in with required per manufacturer's. Electric heaters operating. System is a R22 system that is older. System is operating at this time. Upgrading to a higher sear and new refrigerant 410A system would help with power consumption and comfort level in building