Inspected condensing unit determined it does not need to be moved, customer is going to build a way to divert water from falling directly on the condensing unit. At least eight feet of clearance above condensing unit to ensure proper heat exchange. Inspected ductwork discovered that all ductworkin second floor is metal. Customer is going to have duct cleaning done. Customeris going to improve access to first story crawl space so we can do further investigations and determine if any needs to be replaced. After which we can devise a plan to add a return to the upstairs. Customer will contact us in the fall to perform a duct diagnostic to see if aeroseal is applicable to his situation and if it is needed. Will perform heat load calculation at that time to determine if current unit is sized correctly for home. After heat load calculation and duct diagnostic will provide estimates for system replacement, duct replacement, aeroseal, and additional supply/ return ducts.