7908 Rutillio Ct
New Port Richey, FL 34653
(727) 375-2665

Local Reviews
for new port richey, fl

Rated 4.9 out of 5 stars based on 147 customer reviews

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast service

Jeff took ball and ran with it ... AC was down at property , appreciate the great service !!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Totally awesome! Came on Saturday night. Fixed our a/c immediately.

He was super polite and hadn’t even eaten super.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Awesome Price!

Very professional and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ac Service

Jeff did a great job and was very knowledgeable. Thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Very knowledgeable and friendly service man. Price quite reasonable. Fast service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service , awesome price

I would love Jeff to come back for a yearly service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Perfect

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good service and advice from Glen on clearing drain pipe.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Perfect

Prompt, efficient, neat and tidy.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for new port richey, fl

Cliff P.

Cliff P. Job Checkin

Performance system diagnostic on the rooftop commercial unit #9832 , upon arrival, main power of shopping plaza was out due a power outage, afterwards power restored , breaker was tripped, traced main power and high voltage not present in the rooftop system, unit have several fuses that need replacement, called property owner several times, no calls were answered


Cliff P.

Cliff P. Job Checkin

Worked up the estimate for the upsized unit at the customers request.


Cliff P.

Cliff P. Job Checkin

Service call completed, safety switch open on arrival, drain and flush condensation line, all system vital are good at this time, send invoices to account


Cliff P.

Cliff P. Job Checkin

16 SEER 10 year parts and 1 year labor warranty


Marc M.

Marc M. Job Checkin

Went over the customer's concerns with her air flow and humidity control. Turned on the super dehumidification and showed the customer the operations of each mode. (100% cooling, 80% dehum mode, and 60% super dehumidification.) Customer may want us to come back to set the CFM pin to Lo instead of Norm.


Cliff P.

Cliff P. Job Checkin

high voltage wires nut melted into low voltage wires, replace and re-insulate wires , replace 3 amp fuse , need to return to replace blower module , part order send .......unit number 12 This is a nursery home please expedite the part replacement


Cliff P.

Cliff P. Job Checkin

Maintenance completed, drain and flush condensation line , replace air filter and advised client to replace air filter regularly, check refrigerant pressure and electrical components , re- route drain line for easy access for cleaning, unit is 14 years old with r-22 refrigerant, quote for new system on the email on file


Jeff M.

Jeff M. Job Checkin

Upon arrival the tenants said that it would start to freeze up when they dropped set point to 73. I checked filter and there was no filter. I checked pressures and subcooling and was a little low. I went to airhandler to check coil. There was an existing access in return plenum so I removed tape and found coil very dirty. I cleaned coil and then vacuumed all the dirt from pan so drainline would drain. I rechecked pressures and then added 1 lb R22 refrigerant. The evaporator coil is not in good condition but I feel it is as clean as I can get it at this time.


Cliff P.

Cliff P. Job Checkin

Installed temporary blower motor in system set to be replaced in September.


Jeff M.

Jeff M. Job Checkin

Upon arrival I checked airhandler and found blower wheel had broke at hub. To keep cooling I need a blower wheel from old unit. I took old blower housing and motor to try and match wheel.


Jeff M.

Jeff M. Job Checkin

Upon arrival the condenser fan won't start. I found new Amrad capacitor open on fan side. So I replaced under 2 labor 5 year part. It is cooling at this time.


Jeff M.

Jeff M. Job Checkin

Annual ac maintenance tuneup and cleaning. I got new equipment information. I checked all amp draws and pressures and were fine. I cleaned evaporator coil and condenser coil. I flushed drainline and is draining well. I did not find any issues at this time.


Cliff P.

Cliff P. Job Checkin

Found outdoor condenser fan blade broken and condenser motor damaged . Both will need to be replaced with factory OEM parts Cost is pending. Outdoor coil was also damaged but system is holding refrigerant pressure at this time.


Jeff M.

Jeff M. Job Checkin

Upon arrival the unit was running but no condenser. I checked float switch and the float had fallen off the stem. I reinstalled float but condenser would not start. I found open capacitor and replaced it. CAP505A. I checked warranty and it had expired. It is cooling and draining at this time.


Jeff M.

Jeff M. Job Checkin

Upon arrival the secondary pan float had tripped. I removed panel and vacuumed pan and drainline. I flushed drainline multiple times with dawn. Do to the frequency of drainline problems I am coming back with drainline kit to clean drainline. It is clogging every 2 weeks.