BayArea has great technicians that are dedicated to great service and knowledgeable info to their customers. We have used them for over 20 yrs and our first call if AC system needs service.
Quick & efficient service. Knowledgeable & friendly service technicians
The Technician quickly and accurately determined the system was functioning correctly and no repairs were required. He made pressure and temperature measurements as required and provided a detailed email with all the readings. Nothing to hide here ... just a a very good company. Thanks!
Glen was fantastic! Extremely knowledgeable. Glen called first thing in the morning and kept me up to date with where he was and when he would arrive. Quick and efficient and super friendly.
Very personable and knowledgeable. The issue was explained in a way I could understand
We have used Bay Area AC for yrs and always impressed with the professionalism, knowledge & courtesy of the techs. Glenn was on time, friendly and very knowledgeable. We will call Bay Area in the future.
Cliff was prompt and extremely knowledgeable and educational.
Jeff is an asset to your company.
Routine Tune Up AHU has a piston, based on superheat the refrigerant charge is a little low Added refrigerant to 11° superheat
Upon arrival I checked the capacitor and contactor to be sure it was not causing breaker to trip. Then I ohmed compressor. I found pin blown out of compressor. Compressor needs replaced. I quoted a Bryant unit.
Found no power to the condenser due to a tripped breaker. The compressor is shorted. Recommended system replacement. The customer would like only the condenser replaced. I was told by Dale that we will not just install a condenser on a nine year old air handler.
Ran complete system tune up. After adjusting sub-cool to proper charge with 8 oz of 410A. System working within factory specifications. Cleaned and treated coils and drain. Flushed and cleaned drain. Washed and waxed OD unit.
Found two factory wires disconnected. Reconnected those wires and started the system.
10 year parts and labor warranty
Checked over the system and found that the reversing valve isn't switching over into cooling mode.
Had lengthy conversation with Mrs. All the symptomns she described to me were related to heat pump defrost cycle and are normal functions
Wall cavity behind garage AHU is a "wall plenum" Wall opposite which is in bathroom is removed Several areas were noted as gaps allowing attic air intrusion which should be sealed prior to re-rocking wall Quote is 420.00 to 560.00 to seal exposed areas Contractor or customer to coordinate a RS
Did tune up on apartment 101. 3019 Bonaventure cir palm harbor 34684.
Found that unit was tampered with and was low on freon. Everything that was done was sent on first invoice. Found that unit was 3lbs low on freon. Charged on first invoice.
Found that defrost control not functional on unit #1 unit was coming on for 2 or 3 seconds then shutting down made sure pressure switch on suction line is still working properly and also made sure pressures good found that there was no disconnect handle or Deadman plate used new one out of new disconnect. Price that was told for defrost control board 278$ Unit number 2 found that unit had leak valve stem was 1/2 turned out system took 3 lbs of 410a to get charges where needed. Customer is calling in to pay.
Upon arrival customer stated that units are not heating. The two straight cool units were set to heat and both heat strips were not coming on. Inspected heat strip on both units and noticed that they were not wired. Heat is now functioning properly.
Alt # 7277096733., System off on float switch. Clear drain and pan. Check system operation. Heat strip operating but no call for Heat pump. Ordered new zone control board..
Did tune up cleaned drain pan unit is operating where it is supposed too