Matt C. made sure everything was installed and running perfectly. They were clean and professional.
They worked hard & made sure everything was right. And they even cleaned up the area when finished.
This is the most knowledgeable through service man I have ever had. He went beyond cleaning outside and inside unit and answered all my questions. He is beyond reproach in his service.
immediate reply, prompt arrival, knowledgeable technician, solved the problem instantly
Completed maintenance. Customer stated that thermostat states to replace UV lamp. UV lamp is not being powered when the system is on despite having 24V. Cleaned indoor and outdoor coils, vacuumed and flushed drain line, cleaned and waxed outdoor unit and pad. Refrigerant pressures, static pressures, and temperature splits are all normal. Filter size 18x30x1.
Put sticker on unit, unit is ready for inspection
RE USE EXISTING HEAT STRIP PER DAVID T 474
Upon arrival the homeowner said it was too dark and late. I got held up on prior job. She did not get my phone message. She wants to reschedule for my second call tomorrow.
Checked over the system to find everything to be working as designed. 53 percent humidity. 77 degree return air with. 55 degree supply air temperature. 56 degree wetbulb. 125/316 psi 12 degree Superheat. 8 degree Subcooling. 55 degree suction line temperature. 92 degree liquid line temperature. Sealed the air handler around the return and resealed around the supply. The system cooled down 3 degrees while checking it's operation.
Installed the metal riser. 4/9 Assisted Matt C with 16" metal RA riser
Checked over the system to find everything to be working as designed. 53 percent humidity. 77 degree return air with. 55 degree supply air temperature. 56 degree wetbulb. 125/316 psi 12 degree Superheat. 8 degree Subcooling. 55 degree suction line temperature. 92 degree liquid line temperature. Sealed the air handler around the return and resealed around the supply. The system cooled down 3 degrees while checking it's operation.
Found that the filter door was making a noise. Sealed the top and bottom of the filter door and also tightened all the screws on the outside condenser.
This is An Estimate to Install A New Carrier 16 seer Two Stage Heat Pump.
Went over the install, helped Wes with a couple things while on the job site. The one concern I have is that the condenser is not at least 12 inches away from the house.
Found that the customer already set up the wifi. Went over the customers questions about the thermostat. Set up the schedule and backlight settings.
ANNUAL AC MAINTENANCE TUNE UP AND CLEANING ON A 3.5 TON CARRIER HEAT PUMP SYSTEM.
Replace dual capacitor on a 5-ton carrier Comfort system New Port Richey
Another tune up on Carrier heat pump air conditioning system in San Antonio