Benson’s Service Call

Maintenance service plan call. On time. Curteous, keep me informed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Knowledgeable Technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional

Thank you for a timely response to my call and resolving my issue in a clean professional manner

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Service

Jason and fellow tech kept me informed at every step. However they arrive outside the service window.

  • Overall Experience
  • Quality
  • Price
  • Convenience

On Time

On time and great service, Thanks!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Knowledgeable Technician

Very nice person.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for alligator point, fl

Lee C.

Lee C. Job Checkin

Today we performed a silver level summertime tuneup on your Bryant heat pump unit and on your Daikin mini split unit. We installed surge protectors on the indoor unit and on the mini split to protect the units from any surge or blow out. We also added your mini split to your Silver level maintenance plan. Everything is working properly at this time. Alligator Point Fl


Justin P.

Justin P. Job Checkin

Today we performed a Silver level summer tune up on your three Bryant heat pump units, everything is working properly at this time. Thank you for your business. Alligator Point Fl


Lee C.

Lee C. Job Checkin

Replaced leaking evaporator coil in west side air handler with a new factory coil. Pressure tested with nitrogen to ensure there were no more leaks, pulled system down on a deep vacuum, fired system off, monitored system operations, and refrigerant pressures. I added one more pound of refrigerant to reach desired sub cooling. The system is now cooling properly at this time. The new coil comes with a one year warranty. Billable.


Chris D.

Chris D. Job Checkin

I performed a Silver level Summer time tune up on the Daikin equipment today in Alligator Point, Florida. Thank you for your business today.


Lee C.

Lee C. Job Checkin

I performed a tune up on the equipment. Tested system operations, component amperages, capacitor ratings, checked refrigerant pressures, cleared the drain lines, changed all the filters, checked all the dampers to ensure they were open, and disinfected every surface I touched in the house. I found the master bedroom system was slightly low on refrigerant charge. I added one pound of r410 refrigerant to reach the desired sub cooling. I performed an electronic leak search on the indoor coil and did pick up a refrigerant leak. I will check warranty status of the new coil and email an estimate to replace the evaporator coil in that air handler. Both systems are now cooling properly at this time. I will bring 4 of each filters at the next maintenance because you only have one left. Billable


Justin P.

Justin P. Job Checkin

Today we performed a Bensons level winter tune up on your Goodman heat pump unit, everything is working properly at this time. Thank you for your business. Panacea Fl


Chris D.

Chris D. Job Checkin

I performed a Silver level winter time tune up on the equipment. Testing syst operations, component amperages, capacitor ratings, cleared the drain line, checked the air filter, checked the thermostat, and cleaned the condenser outside. The system is working properly at this time in heating mode. Thank you for your business today. Alligator Point, Florida.


Justin P.

Justin P. Job Checkin

Today we performed a Silver level winter tune up on your three Payne heat pump units, everything is working properly at this time. Thank you for your business. Alligator Point Fl


Justin P.

Justin P. Job Checkin

Today we performed a Silver level winter tune up on your Bryant heat pump unit. We Installed a surge protector on the the main outdoor unit to protect the unit from any surge or blow out. Everything is working properly at this time. Thank you for your business. Alligator Point Fl


Justin P.

Justin P. Job Checkin

Today we performed a Silver level winter tune up on your two outdoor units and on your four indoor units Daikin heat pump mini split units, everything is working properly at this time. Thank you for your business. Alligator Point Fl


Wade N.

Wade N. Job Checkin

Today we performed a summer time tune up on your mini splits. Everything is working properly at this time. Thank ou for your business!


Justin P.

Justin P. Job Checkin

Today we performed a Silver level summer tune up on your Comfortmaker heat pump unit, everything is working properly at this time. Thank you for your business. Alligator Point Fl


Justin P.

Justin P. Job Checkin

Today we performed a Bensons level summer tune up on your Goodman heat pump unit. We installed surge protectors on the indoor and outdoor unit to protect the units from any surge or blow out. Everything is working properly at this time. Thank you for your business today. Tallahassee, Florida


Justin P.

Justin P. Job Checkin

Today we performed a Silver level summer tune up on both of your American Standard heat pump units. We replaced both worn out Contactors and weak capacitors on the outdoor units. Everything is working properly at this time. Thank you for your business. Alligator Point Fl


Nick S.

Nick S. Job Checkin

The system was leaking water underneath the air handler for the downstairs system. I found the evaporator coil to be completely clogged and needed cleaning. I cleaned the evaporator coil in place and cleared the condensate line. The condensate line was being pushed up at the air handler, creating an upward angle in the drain line. I strapped the drain line dfbmgfown to create a downward angle on the drain line. The system is now draining and operating properly at this time.