The technician, Brendon Noble, was thorough and did a fine job. He was also personable and appeared to enjoy working with customers on behalf of Benson's.
He took his time and assessed the problem. He was patient and listened to what I thought. He stayed until he knew the system was working properly! Thanks so much!
System checked for summer. Very pleased with service visit.
Always considerate, always thorough, always puts the customer first. A good person with a high level of competency.
Today, I arrived on site to perform a summer maintenance check on the HVAC equipment. Overall Equipment Condition: Good condition noted for both indoor and outdoor units. Indoor Unit Details: Located in the attic, identified as a furnace. Servicing the whole home. Respicare filtration system replaced today using customer’s spare filters. Filter size: 20x25. Indoor coil condition: Good and clean. Outdoor Unit Details: Located on the side of the house, identified as straight cool. Outdoor coil condition: Good and clean. Electrical Components: All tested components are functioning properly within manufacturer’s recommended specs: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring System Inspection: Inspected components in good condition: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical wires secured No components found in poor condition. Temperature Readings: Return air temperatur
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Rated as fair. Indoor Unit: * Located in the crawl space. * Services the whole home. * Filtration system updated with a pleated 2-6" filter, replaced today. * Filter size is 20x25x4. Indoor Coil: * Condition is fair. Outdoor Unit: * Positioned on the side of the house. * Coil condition is fair and clean. Electrical Components: * Blower Motor, Heat Strip Kit, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Electrical Wiring, and Electric Heat Strip Kit Safety's tested and functioning within manufacturer specs. * No components found to be malfunctioning. Inspections: * Blower Wheel, Primary Drain Pan, and Electrical Wires are in good condition and working properly. * No components in poor condition. Air Temperatures: * Return Air Temperature: 75.0°F. * Supply Air Temperature: 113.0°F. Condensate Drain System: * Cleared drain line and cleaned out the primary pan.
I preformed a summer time tune up on a nordyne heat pump
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Fair Indoor Unit: - Capture Dataplate Only: Could not find data tag - Location, Type, and Picture: Attic, Furnace Area Unit Services: - Whole house Filtration: - Respicare filter replaced today - Filter Size and Picture: 20x25 Condition of Indoor Coil: - Fair Outdoor Unit: - Location, Type, and Picture: Side of House, Straight Cool - Condition of Outdoor Coil: Fair, cleaned today Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Electrical Wiring - Furnace Control Board Inspected components in good condition and working properly: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - Secondary Drain Pan Tested for Carbon Monoxide: - N/A Return Air Temperature: - 76.0 Degrees Fahrenheit Supply Ai
Performed a summer time tune up on a Lennox Heat Pump View visual findings from this job here - https://visionshare.xoi.io/?id=XA-846D-FCC464AC37F74FB39FD3E9098E1055D4
Heating Repair: The client contacted us due to persistent furnace shutdowns, expressing heightened safety concerns. Our thorough examination revealed adjustments needed for the flame rollout switch. Our skilled technicians expertly addressed the issue by meticulously adjusting the flame rollout limit switch. This precise adjustment not only rectified the immediate concern but also guaranteed the ongoing safe and efficient operation of the furnace, providing the client with enhanced peace of mind and comfort.
Upon arrival found unit primary safety switch to be engaged and several gallons of water in drain opening and under patio as customer showed me . The existing drain line is 3/4 pex line while the inside is 3/4 pvc. To solve this issue I installed an adapter to connect the pex and pvc together. Afterwards I cleared and tested the drainline which is draining properly as well as removed as much water as possible. Thank you for your business.
Today I preformed a Gold level maintenance on your system. I verified the system’s operation. You’re system is operating properly at this time in heat mode. Thank you for your business today. Chattahoochee, Florida.
I performed a Gold level Summer time tune on your equipment today. Checking the system’s operation. Thank you for your business today. Chattahoochee , Fl
I preformed a winter time tune up on a Lennox heat pump