Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Rated as fair. Indoor Unit: * Located in the crawl space. * Services the whole home. * Filtration system updated with a pleated 2-6" filter, replaced today. * Filter size is 20x25x4. Indoor Coil: * Condition is fair. Outdoor Unit: * Positioned on the side of the house. * Coil condition is fair and clean. Electrical Components: * Blower Motor, Heat Strip Kit, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Electrical Wiring, and Electric Heat Strip Kit Safety's tested and functioning within manufacturer specs. * No components found to be malfunctioning. Inspections: * Blower Wheel, Primary Drain Pan, and Electrical Wires are in good condition and working properly. * No components in poor condition. Air Temperatures: * Return Air Temperature: 75.0°F. * Supply Air Temperature: 113.0°F. Condensate Drain System: * Cleared drain line and cleaned out the primary pan.