Today, I performed a winter time maintenance on your HVAC equipment. Here is a summary of the work that was completed: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Closet, Air Handler Area Unit Services: Whole house Filtration: Pleated 1", Replaced Today - Filter Size: 18x18 Condition of Indoor Coil: Good, Clean Location, Type, and Picture of Outdoor Unit: Back Yard, Heat Pump Condition of Outdoor Coil: Cleaned Today, Fair I tested and inspected the following electrical components on your equipment and they are working properly within the manufacturers' recommended specs and amperages: - Blower Motor - Inducer Draft Motor - Heat Strip Kit - Condenser Fan Motor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Defrost Control Board - Electrical Wiring - Electric Heat Strip Kit Safety's There were no electrical components found to be not working properly or not within the manufactur
Today I performed a winter time tune up on your Amana heat pump unit. Everything is working properly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A42C-B8770A1CE87B4ACB8E113C8B985FCD7C
Today I performed a winter time tune up on your Lennox heat pump unit. Everything is working properly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A42C-17C83A611BCA492CB321DE04CAA6FB1E
Today I performed a summer time tune up on your American standard air handler and Heat-pump, your system is working properly at this time.Tallahassee Fl View visual findings from this job here - https://visionshare.xoi.io/?id=XA-BE96-E028E7B7A7854248A6274E36C88ACDB1
Today I performed a summertime tune up on your heat pump unit. Everything is working properly at this time. Thank you for your business. Tallahassee FL View visual findings from this job here - https://visionshare.xoi.io/?id=XA-0090-636E43C14CDA48098BDF7650AE290797
Today I performed a summer time tune up on your Bensons Heat-pump, your system is working properly at this time.Tallahassee Fl View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A44C-2458B2D2BE7148E5BCE4410168AF5706
Today we performed a summer time tune up on your Goodman Heat Pump unit, everything is working properly at this time. Thank you for your business. Tallahassee FL
Today I performed a summertime tune up on your American Standard heat pump unit. Everything is working properly at this time. Thank you for your business. Madison FL View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EFF3-0BB9238D5547462C8F4F5F24F39D950F
I performed a winter time tune up on a Grand Aire Heat Pump unit in Madison,Fl View visual findings from this job here - https://visionshare.xoi.io/?id=XA-D9CB-705921C267AF4B0F884C4724CEF3A45A
I did a winter time tuneup on a Lennox heat pump everything is working properly at this time in cooling and heating mode
Today we performed a winter time tune up on your heat pump unit,everything is working properly at this time .Thank you for your business. Tallahassee FL
Today we performed a winter time tune up on your unit,everything is working properly at this time .Thank you for your business. Tallahassee FL
I performed a summer time tune up on a Lennox Air Conditioner unit in Madison,FL Thank you for your business
Today we performed a summer time tune up on your Goodman heat pump unit ,everything is working properly at this time . Tallahassee FL
Diag/ kitchen minisplit not heating and is blowing room temp air, customer said all the others are heating but none of the heads are showing error codes. Found EEV motor for circuit D (serves kitchen) wasn’t working properly, switched with the one for circuit C (serves storage room), and kitchen head is now heating and cooling properly. Ordered new EEV stepper motor for circuit D and returned and replaced motor Y4E, put original motor back on circuit C. Tested system and all heads are heating properly at this time.