Very impressed with him. Courteous, polite, explained everything he did. Talked with him how to order more filters. ⭐⭐⭐⭐⭐ Will request him next time
Aiden did a a very good job checking everything out. He was very friendly and informative.
I had a very good experience with this tech , he was very professional and courteous.
Response from Benson's Heating and Air Conditioning:
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
Service was great!
Response from Benson's Heating and Air Conditioning:
Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.
He was very knowledgeable and on time.
He was punctual, and did a really great job. He offered suggestions to me about improvements for my unit, etc. and went above and beyond. I really appreciated it.
Today, I arrived on site to perform winter maintenance on your HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Type: Air Handler located in the garage attic. * Services: Whole home. * Filtration: Pleated 2-6" filter replaced today. * Filter Size: 20x20. * Indoor Coil: Good and clean condition. Outdoor Unit Details: * Type: Heat Pump located on the side of the house. * Outdoor Coil: Good and clean condition. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring System Inspections: * Components in good condition: * Blower Wheel * Electrical Wires Secured * Primary Drain Pan * Secondary Drain Pan * No components found in poor condition. Temperature Readings: *
Performed a winter time tune up on a Goodman Heat Pump View visual findings from this job here - https://visionshare.xoi.io/?id=XA-3DDB-232164A9A3FA445BB57D1F8177955C22
Performed a winter time tune up on a ICP aqua coil unit View visual findings from this job here - https://visionshare.xoi.io/?id=XA-0DA0-2C213B44A20F411488C6DD8DEA545050
Job Summary Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition Equipment condition is good. Indoor Unit Details Location: Attic Type: Air Handler Services: Entire house Filtration: Pleated 1" filter replaced today Filter Size: 20x30x1 Indoor Coil Condition: Good and clean Outdoor Unit Details Location: Back Yard Type: Heat Pump Outdoor Coil Condition: Good and cleaned today Electrical Components Tested and inspected the following components, all working properly: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring Inspections Components in good condition: Blower Wheel Primary Drain Pan Secondary Drain Pan Electrical Wires secured Temperature Readings Return Air Temperature: 74.3°F Supply Air Temperature: 54.8°F Condensate Drain System Cleared drain line Cleaned out primary and secondary pans Tested safety switch Additional Notes Wore shoe covers Dusted return gr
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: Good Indoor Unit: Location: Garage, Attic Type: Air Handler Area Unit Services: Whole home Filtration: Antimicrobial Replaced today Filter: Size: 18x18x1 Indoor Coil: Condition: Good, Clean Outdoor Unit: Location: Side of House Type: Heat Pump Outdoor Coil: Condition: Good, Clean Cleaned today Tested and inspected electrical components: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Inspected components in good condition and working properly: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires Secured Tested for Carbon Monoxide: N/A Return Air Temperature: 72.0 Degrees Fahrenheit Supply Air Temperature: 51.0 Degrees Fahrenheit Condensate Drain System: Cleared Drain Line Cleaned Out Primary Pan Tested Safe
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Attic Air Handler Area Unit Services: The air handler is in the attic and services the main office area Filtration: Pleated 1" Replaced today Filter Size and Picture of filter: 21.5x23.31x1 Condition of Indoor Coil: Good Location, Type, and Picture of Outdoor Unit: Side of Building Heat Pump Condition of Outdoor Coil: Good Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: N/A Inspected these components on your sys
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Attic - Air Handler Area Unit Services: - Whole house Filtration: - Pleated 1" - Replaced today Filter Size and Picture of filter: - (4) 12x12x1 - (1) 18x18x1 - (1) 16x20x1 Condition of Indoor Coil: - Good - Clean Location, Type, and Picture of Outdoor Unit: - Side of House - Heat Pump Condition of Outdoor Coil: - Good - Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring Inspected these components on your system and they are in good condition and working properly at this time: - Blower Wheel - Secondary Dr
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Fair Location, Type, and Picture of Indoor Unit: - Attic, Garage Area Unit Services: - Whole house Filtration: - Pleated 1", Checked Today Filter Size and Picture of filter: - 20x20x1 Condition of Indoor Coil: - Fair Location, Type, and Picture of Outdoor Unit: - Side of House Condition of Outdoor Coil: - Fair Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: - N/A Inspected these components on your system and they are in good
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Fair Location, Type, and Picture of Indoor Unit: - Attic - Garage Area Unit Services: - Whole house Filtration: - Pleated 1" - Checked today Filter Size and Picture of filter: - 12X12X1 - 18X24X1 - 14X20X1 Condition of Indoor Coil: - Fair Location, Type, and Picture of Outdoor Unit: - Side of House Condition of Outdoor Coil: - Fair Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Fan Run Capacitor - Compressor Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Inspected these components on your system and they are in good condition and working properly at this time: - Blower Wheel - Secondary Drain Pan - Primary Drain Pan - Electrical Wires Secured Test
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Attic, Garage - Type: Air Handler - Picture: Available Area Unit Services: - Whole house Filtration: - Pleated 2-6" - Checked today Filter: - Size: 20x20x4 - Picture: Available Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: Available Condition of Outdoor Coil: - Good - Clean - Cleaned today Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Secondary Drain Pan - Primary Drain Pan - Electrical Wires Secured Tested for Carbon Monoxide: - N/A Return Air Temperature: - 71.7 Degrees Fahrenheit Supply Air Temper
AC Repairs: At the client's residence, I found issues with a malfunctioning crankcase heater thermostat in their HVAC system. I replaced the thermostat to prevent compressor damage and ensure proper oil circulation.
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: Fair Location, Type, and Picture of Indoor Unit: Air Handler Closet Area Unit Services: Whole home Filtration: Pleated 1" Checked today Filter Size and Picture of filter: 18x24x1 Condition of Indoor Coil: Fair Clean Location, Type, and Picture of Outdoor Unit: Side of House Heat Pump Condition of Outdoor Coil: Good Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperages: Blower Motor Condenser Fan Motor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Compressor Contactor Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperages: N/A Inspected these components on your system and they are in good conditi
I performed a winter time tune up on a Comfortmaker heat pump
Today I performed a wintertime tuneup on your Goodman Heat Pump Unit. Everything is working properly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-1964-96C3D25E19CC46549D2056CD8F997D3B
Today I performed a wintertime tuneup on your Goodman Heat Pump Unit in Midway. Everything is working properly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-1964-08EB1938AE7B4502B10C33B778BD6AF7