5402 Tower Rd
Tallahassee, FL 32303
850-562-3132

Local Reviews
for midway, fl

Rated 4.9 out of 5 stars based on 35 customer reviews

Friendly, Efficient and Excellent Service

He was training someone and did an overall excellent job. I was very satisfied.


Response from Benson's Heating and Air Conditioning:

We really appreciate you taking the time to share your feedback with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Benson's Heating and Air Conditioning:

We thank you for sharing your positive experience. It made our day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Very efficient and quick. No problems at all.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Very impressed with him. Courteous, polite, explained everything he did. Talked with him how to order more filters. ⭐⭐⭐⭐⭐ Will request him next time

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Aiden did a a very good job checking everything out. He was very friendly and informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

No issues. He was polite and thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Type of service

I had a very good experience with this tech , he was very professional and courteous.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Friendly and Knowledgeable

Ej seemed very friendly and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service


Response from Benson's Heating and Air Conditioning:

Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Bobby Gifford

ALL GOOG

  • Overall Experience
  • Quality
  • Price
  • Convenience

Ms.

Service was great!


Response from Benson's Heating and Air Conditioning:

Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

He did a great job and was able to answer all of my questions.

He was very knowledgeable and on time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

He was very pleasant, professional, knowledgeable, great service!

He was punctual, and did a really great job. He offered suggestions to me about improvements for my unit, etc. and went above and beyond. I really appreciated it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for midway, fl

Bryce D.

Bryce D. Job Checkin

Today, I arrived on site to perform a summer time maintenance on the HVAC equipment. Equipment Condition: * Overall condition of the system is fair. * Indoor unit located in the closet; air handler servicing the whole home. Filtration: * Washable filter was cleaned today. * Filter size is 18x24x1. Coils: * Indoor coil condition is fair and clean. * Outdoor unit located on the side of the house; heat pump with fair and clean coil, cleaned today. Electrical Components: * Blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring tested and working properly within manufacturer specs. * No electrical components found not working properly. System Components: * Blower wheel, primary drain pan, and electrical wires inspected; all in good condition and functioning properly. * No components found in poor condition. Testing and Inspections: * Carbon monoxide testing was not applicable. * Return air temperature registered at


Brenden N.

Brenden N. Job Checkin

Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition: * Condition rated as fair. Indoor Unit Details: * Located in the attic; type is air handler. * Services the whole home. * Pleated 1" filtration; customer has spare filters but prefers to replace them independently. * Filter size is 20x30x1. Indoor Coil Condition: * Rated as fair. Outdoor Unit Details: * Located in the back yard; type is heat pump. * Condition is fair; cleaned today. Electrical Components: * Blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring tested and are functioning within manufacturer specifications. Component Inspections: * Blower wheel, electrical wires secured, primary drain pan, and secondary drain pan inspected; all in good working condition. * No components found in poor condition. Testing Results: * No carbon monoxide detected. * Return air temperature measured at 74.4 degree


Kilian  L.

Kilian L. Job Checkin

Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: Good condition noted for both indoor and outdoor units. Indoor Unit Details: Located in the attic of the garage. Type: Air Handler. Filtration system: Respicare; replaced with spare filters provided by the customer. Filter size: 16x20. Indoor coil condition: Good and clean. Outdoor Unit Details: Located on the side of the house. Type: Heat Pump. Outdoor coil condition: Good and clean. Electrical Components: Tested and inspected the following components: Blower Motor: working properly. Compressor Run Capacitor: within specs. Fan Run Capacitor: within specs. Compressor Start Capacitor: within specs. Contactor: functioning correctly. Electrical Wiring: secure and operational. System Inspections: Inspected components in good condition: Blower Wheel. Secondary Drain Pan. Primary Drain Pan. Cleared the condensate drain line and cleaned both pans. Tested the safety switch. Additional Tasks:


Kilian  L.

Kilian L. Job Checkin

Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition: Equipment is in good condition. Indoor Unit: Located in the garage attic. Type: Air Handler. Filtration system is antimicrobial and was replaced today. Filter size is 18x18x1. Indoor Coil: Condition is good and clean. Outdoor Unit: Located on the side of the house. Type: Heat Pump. Outdoor coil is also in good and clean condition. Electrical Components: Tested and inspected the following components: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring All components are working properly within manufacturer’s recommended specs and amperages. System Inspection: Inspected the following components: Blower Wheel Secondary Drain Pan Electrical Wires Secured Primary Drain Pan All inspected components are in good condition and functioning properly. Temperature Readings: Return Air Temperature:


Aj S.

Aj S. Job Checkin

Today, I arrived on site to perform a winter time maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the attic garage. * Type: Air Handler. * Services the whole home. * Filtration system: Pleated 2-6", checked today. * Filter size: 16x20, in good condition. * Indoor coil: Good and clean. Outdoor Unit Details: * Located on the side of the house. * Type: Heat Pump. * Outdoor coil: Good and clean, cleaned today. Electrical Components: * All tested components are working properly within manufacturer’s recommended specs: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Defrost Control Board * Electrical Wiring * Electric Heat Strip Kit Safety's Inspections: * Blower Wheel, Secondary Drain Pan, Primary Drain Pan, and Electrical Wires secured are in good co


Sebastian C.

Sebastian C. Job Checkin

Today, I arrived on site to perform a winter maintenance check on the HVAC equipment. Overall Equipment Condition: * Rated as fair. Indoor Unit Details: * Located in the attic and garage. * Services the whole home. * Filtration system updated with a pleated 1" filter, size 20x20x1. Indoor Coil Condition: * Found to be fair and dirty. * Recommended duct cleaning for improved performance. Outdoor Unit Details: * Positioned on the side of the house. * Condition rated as fair. Electrical Components: * Successfully tested and inspected the following components: * Blower Motor * Heat Strip Kit * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring * Electric Heat Strip Kit Safety's * All components are functioning within manufacturer specifications. Additional Inspections: * Blower Wheel, Primary Drain Pan, Electrical Wires, and Secondary Drain Pan are in good condition. * No components found in poor condition. Temperature Readings:


Sebastian C.

Sebastian C. Job Checkin

Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Fair condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the attic of the garage. * Services the whole home. * Filtration system is pleated 1"; customer will provide their own filters. * Filter sizes: 12X12X1, 18X24X1, and 14X20X1. * Indoor coil condition is fair. Outdoor Unit Details: * Located on the side of the house. * Outdoor coil condition is fair. Electrical Components: * Blower Motor, Heat Strip Kit, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Electrical Wiring, and Electric Heat Strip Kit Safety's tested and functioning within manufacturer's specs. * No components were found to be malfunctioning. Inspections: * Blower Wheel, Primary Drain Pan, Electrical Wires Secured, and Secondary Drain Pan are in good condition. * No components were found in poor condition. Temperature Readings: * Return Air Temperature: 89.0°F *


Brenden N.

Brenden N. Job Checkin

Today, I arrived on site to perform winter maintenance on your HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Type: Air Handler located in the garage attic. * Services: Whole home. * Filtration: Pleated 2-6" filter replaced today. * Filter Size: 20x20. * Indoor Coil: Good and clean condition. Outdoor Unit Details: * Type: Heat Pump located on the side of the house. * Outdoor Coil: Good and clean condition. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring System Inspections: * Components in good condition: * Blower Wheel * Electrical Wires Secured * Primary Drain Pan * Secondary Drain Pan * No components found in poor condition. Temperature Readings: *


Phillip R.

Phillip R. Job Checkin

Performed a winter time tune up on a Goodman Heat Pump View visual findings from this job here - https://visionshare.xoi.io/?id=XA-3DDB-232164A9A3FA445BB57D1F8177955C22


Phillip R.

Phillip R. Job Checkin

Performed a winter time tune up on a ICP aqua coil unit View visual findings from this job here - https://visionshare.xoi.io/?id=XA-0DA0-2C213B44A20F411488C6DD8DEA545050


Hunter C.

Hunter C. Job Checkin

Job Summary Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition Equipment condition is good. Indoor Unit Details Location: Attic Type: Air Handler Services: Entire house Filtration: Pleated 1" filter replaced today Filter Size: 20x30x1 Indoor Coil Condition: Good and clean Outdoor Unit Details Location: Back Yard Type: Heat Pump Outdoor Coil Condition: Good and cleaned today Electrical Components Tested and inspected the following components, all working properly: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring Inspections Components in good condition: Blower Wheel Primary Drain Pan Secondary Drain Pan Electrical Wires secured Temperature Readings Return Air Temperature: 74.3°F Supply Air Temperature: 54.8°F Condensate Drain System Cleared drain line Cleaned out primary and secondary pans Tested safety switch Additional Notes Wore shoe covers Dusted return gr


Junior R.

Junior R. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: Good Indoor Unit: Location: Garage, Attic Type: Air Handler Area Unit Services: Whole home Filtration: Antimicrobial Replaced today Filter: Size: 18x18x1 Indoor Coil: Condition: Good, Clean Outdoor Unit: Location: Side of House Type: Heat Pump Outdoor Coil: Condition: Good, Clean Cleaned today Tested and inspected electrical components: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Inspected components in good condition and working properly: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires Secured Tested for Carbon Monoxide: N/A Return Air Temperature: 72.0 Degrees Fahrenheit Supply Air Temperature: 51.0 Degrees Fahrenheit Condensate Drain System: Cleared Drain Line Cleaned Out Primary Pan Tested Safe


Hunter C.

Hunter C. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Attic Air Handler Area Unit Services: The air handler is in the attic and services the main office area Filtration: Pleated 1" Replaced today Filter Size and Picture of filter: 21.5x23.31x1 Condition of Indoor Coil: Good Location, Type, and Picture of Outdoor Unit: Side of Building Heat Pump Condition of Outdoor Coil: Good Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: N/A Inspected these components on your sys


Aj S.

Aj S. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Attic - Air Handler Area Unit Services: - Whole house Filtration: - Pleated 1" - Replaced today Filter Size and Picture of filter: - (4) 12x12x1 - (1) 18x18x1 - (1) 16x20x1 Condition of Indoor Coil: - Good - Clean Location, Type, and Picture of Outdoor Unit: - Side of House - Heat Pump Condition of Outdoor Coil: - Good - Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring Inspected these components on your system and they are in good condition and working properly at this time: - Blower Wheel - Secondary Dr


Sebastian C.

Sebastian C. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Fair Location, Type, and Picture of Indoor Unit: - Attic, Garage Area Unit Services: - Whole house Filtration: - Pleated 1", Checked Today Filter Size and Picture of filter: - 20x20x1 Condition of Indoor Coil: - Fair Location, Type, and Picture of Outdoor Unit: - Side of House Condition of Outdoor Coil: - Fair Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: - N/A Inspected these components on your system and they are in good