Upon arrival, I found the customers Goodman package unit not cooling properly due to a bad condenser fan motor, and a bad capacitor for the indoor blower motor. I sent the customer an estimate to replace the condenser motor and indoor motor capacitor. She approved both of the estimates. After installing the condenser fan motor and the capacitor the system come on and started cooling. I then found the system to be low on Freon (410A). I sent the customer an estimate for 3 pounds of freon. The system holds almost 11 pounds of 410A. The estimate was approved. The 3 pounds of Freon got the pressures up where they need to be. The customer was not interested in a new system at the moment.Your system is operating properly at this time.