Really good service, great personality and communicator

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for ochlockonee bay, fl

Aj S.

Aj S. Job Checkin

Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Located in the closet, servicing the whole home. * Replaced the pleated 1" filter (20x20x1). * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump):** * Located on the side of the house. * Verified the outdoor coil is clean and in good condition. **Electrical Components:** * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. **System Components:** * Inspected and confirmed good condition of the blower wheel, secondary drain pan, primary drain pan, secured electrical wires, and ductwork. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch. **Temperature Readings:** * Return air temperature: 72.0°F. * Supply air tem


Aidan D.

Aidan D. Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Closet - Type: Air Handler - Picture: [Attached] Area Unit Services: - Whole home Filtration: - Pleated 1" - Checked today Filter: - Size: 20x20x1 - Picture: [Attached] Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Attached] Condition of Outdoor Coil: - Good - Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Inspected these components on your system and they are in good condition and working properly at this time: - Blower Wheel - Electrical Wires Secu


Aidan D.

Aidan D. Job Checkin

Today I performed a wintertime tuneup on your Bryant air conditioning unit in Ochlockonee Bay. Everything is working properly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-1964-6E65A862B89143198634AAE91832FBE6