This young man was on time, courteous, polite and done a good job. Need more workers like him.
Nice, polite and Being respectful of me and my home. He wore a mask, gloves and shoe covers. He performed the tune up and finished in a timely manor. Also recommended another service that is possibly needed. Thanks,
Showed up on the scheduled date, polite, knowledgeable and professional like.
Today, I arrived on site to perform a summer maintenance check on your HVAC equipment. Equipment Condition: * Overall equipment condition is good. * Indoor coil and outdoor coil are clean and in good condition. Indoor Unit Details: * Location: Closet, Air Handler. * Servicing area: Whole home. * Filtration: Pleated 1" filter, checked today. * Filter size: 20x20. Outdoor Unit Details: * Location: Side of house, Heat Pump. Electrical Components: * All tested electrical components are functioning properly within manufacturer’s recommended specs: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring System Inspections: * Inspected components in good condition: * Blower Wheel * Primary Drain Pan * Secondary Drain Pan * Electrical wires secured * No components found in poor condition. Testing Results: * Carbon Monoxide: 0.0
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Closet - Type: Air Handler - Picture: [Provide picture if available] Area Unit Services: - Whole house Filtration: - Pleated 1" - Checked today Filter: - Size: 20x20 - Picture: [Provide picture if available] Indoor Coil: - Condition: Good, Clean - Brush cleaned today Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Provide picture if available] Outdoor Coil: - Condition: Good, Clean - Cleaned today Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Primary Drain Pan - Electrical Wires Secured Tested for Carbon Monoxide: - N/A Temperature readings: - Return Air Temperat
Today I performed a wintertime tuneup on your Rheem air conditioning unit. Everything is working properly at this time.
Today I performed a summer time tune up on your Rheem Heat-pump, your system is working properly at this time.Tallahassee Fl View visual findings from this job here - https://visionshare.xoi.io/?id=XA-3A11-E1B6CD7702174B5D943F9398D23CC5CB
Today I performed a summertime tune up on your Rheem heat pump unit. Everything is working properly at this time. Thank you for your business. Climax GA