N967 Quality Drive
Greenville, WI 54942
920-757-9990

Local Reviews
for fremont, wi

Rated 4.9 out of 5 stars based on 15 customer reviews

Furnace 1 year check up

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great & speedy service with most knowledgeable tech.

Parts are on order and furnace is working for now, parts to come next week. Dan explained things in terms I could understand and am following his recommendation to the letter. May be pricey, but get only what you pay for today.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very pleased with the service

We were happy with the service provided and the explanation of our problem with our AC and then having the manager come out to also take a look to see if he agreed with the issue. Nice to know they have our back.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very happy with the service and information provided

would recommend you to anyone

  • Overall Experience
  • Quality
  • Price
  • Convenience

always great

  • Overall Experience
  • Quality
  • Price
  • Convenience

always great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Professional, great service.

Kody Wojtalewicz was very Professional, I felt he went above and beyond, A plus service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

very knowledgeable, and nice.

right on time and courteous

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fremont, wi

Hunter D.

Hunter D. Job Checkin

Performed the new furnace start up. No gas leaks detected. Gas and exhaust levels are normal. No CO detected in the air. Venting and electrical components are properly installed. Heat rise was 38 degrees. High limit passed safety check. Unit is heating properly at this time.


Travis W.

Travis W. Job Checkin

Installed new Daikin DM96VE080 gas furnace. Also installed T6 WiFi thermostat. Offered electrostatic filter upgrade and humidifier replacement. May upgrade and/or replace at time of A/C replacement. A/C coil pan is leaking and needs to be replaced.


Anthony N.

Anthony N. Job Checkin

Was here for a furnace no heat. The furnace wasn’t running when I got here. Reset power to the furnace. Cycled the furnace. The burners would light but the blower motor wouldn’t turn on. Found that the circuit board wasn’t allowing power to the blower motor. The furnace is 17 years old. Recommended that they get a second opinnion with my supervisor Dan to go over repair or replace options. Office to schedule Dan for 9am on Monday morning.


Julian  D.

Julian D. Job Checkin

Performed first year furnace cleaning; inspected the exhaust and intake PVC ensuring all connections were secured, removed and cleaned the burners along with the flame sensor, cycled the system on and performed a combustion test verifying no CO in the airstream, also did a refrigerant leak search on the Acoil and did find indicators of a possible leak on the AC system. This system is currently operating normal and heating at 53 degrees at this time. Second opinion scheduled with Dan F today at noon Job complete


Kody W.

Kody W. Job Checkin

Boiler would make a whiny noise. I cycled the boiler. When it had an output of 150000 btu the exhaust blower shroud would vibrate and make a noise. I removed the shroud. We will need to order a new exhaust blower and come back to install it. The boiler is heating at this time.


Kody W.

Kody W. Job Checkin

No heat on oil furnace. The burner was locked out. I checked the cad cell, it was good. Checked clean outs, they were clear. Cycled burner. The burner would try firing but it wasn’t getting constant oil flow. I bled air from the oil line. Cycled the furnace multiple times. It’s heating properly now. No charge since I just cleaned it and forgot to bleed air out of oil line.


Kody W.

Kody W. Job Checkin

No heat on geo unit. I checked unit for fault codes. Found a flow switch fault code. I cleared the code and cycled the geo. It cycled through hydronic heat normally. I checked the flow switch, found it wasn’t aligned correctly on the pipe. I corrected the flow switch alignment. Checked flow center water level. Water is to the top. Level is good. Cycled geo in forced air heat. It’s working properly.


Dean P.

Dean P. Job Checkin

We removed the old furnace and installed a new tempstar furnace. We reconnected all duct, gas line, venting and electrical. Ran new drain line for the furnace only. Cycled the unit, everything is running fine. Thank you


Dan E.

Dan E. Job Checkin

No heat. Cycled system furnace fan and ventor motor both run. Giving code of 4. Checked and cleared condensate trap. It was plugged. Also, found pressure switch was not making. Cleared all pressure lines and removed intake venting. Pressure switch would work if pressure was put on the top of it. Recommend replace pressure switch. Adjusted hose and pressure switch held. Office to quote pressure switch replacement and schedule furnace clean and tune. Furnace is heating at this time. Office to schedule ac clean in spring. Job complete.


Travis W.

Travis W. Job Checkin

Fixed venting leak on boiler exhaust.


Travis W.

Travis W. Job Checkin

Fixed venting leak on boiler exhaust.


Dan E.

Dan E. Job Checkin

Furnace checked. Cycled system. Heat exchanger is rusty. No cracks found. Cleaned flame sensor, checked igniter. Checeked for co in airstream , none found. Normal levels of co and XS air in exhaust. System is rusted, but operating normal at this time. Job complete.


Dan E.

Dan E. Job Checkin

Furnace checked. Cycled system. Heat exchanger is rusty. No cracks found. Cleaned flame sensor, checked igniter. Checeked for co in airstream , none found. Normal levels of co and XS air in exhaust. System is rusted, but operating normal at this time. Job complete.


Bill W.

Bill W. Job Checkin

Ac installation complete


Kody W.

Kody W. Job Checkin

Performed air conditioner clean and tune. I checked the filter and blew out the drain. Performed a leak search on the system. I found the evaporator coil was leaking refrigerant. I cleaned out and tested the electrical components. Washed the condenser coil. Cycled the system and checked the refrigerant charge. The air conditioner is getting low on refrigerant. Dan will be out to verify the leak and give options to move forward. Unit is 13 years old, average life is 12-15 years.