N967 Quality Drive
Greenville, WI 54942
920-757-9990

Local Reviews
for kimberly, wi

Rated 5.0 out of 5 stars based on 8 customer reviews

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

friendly and efficient

answered all my questions that made it easy to understand without acting like I was dumb.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

True professionals, knowledgable and and friendly service. I will definitely use their services again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

We had a small emergency with our A/C on a Saturday, during one of the hottest days of the summer, and they came out quickly and fixed everything! Amazing service and professionalism! Highly recommended.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service and very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thanks Evan!!

Evan was in and out in about an hour, and everything went very well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great srvice

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for kimberly, wi

Anthony N.

Anthony N. Job Checkin

Performed preferred customer furnace start up. Checked over the furnace installation. Found that the 90 degree elbow on th exhaust is leaking water. The pipe is 2 1/2” pipe. Office to call to schedule an appointment for an installer to come repair the leak. Cycled the furnace. Set the furnace gas pressure. Took a temperature rise and set the fan speed. Performed furnace combustion test. The furnace is running normally at this time.


Hunter D.

Hunter D. Job Checkin

Came out to do the quarterly maintenance. Filters are replaced and unit is heating properly.


Anthony N.

Anthony N. Job Checkin

Performed preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Wiped down the inside of the furnace. Cycled the furnace. Checked the motors for proper operation. Performed furnace combustion test. The furnace is running normally at this time.


Hunter D.

Hunter D. Job Checkin

Completed Gas Furnace replacement. Disconnected and removed old furnace and then set new one on blocks in its place. Reconnected the gas, electric, PVC vent pipes, and duct-work to new furnace. Installed a new Thermostat and connected it to the Furnace. Run tested the furnace, but will still need a technician start up. The Office will follow up to schedule a technician to return to do the Furnace efficiency startup, which is required for warranty purposes. Thank you for choosing Black-Haak Heating. Please take a moment to fill out our online survey.


Hunter D.

Hunter D. Job Checkin

Completed Gas Furnace replacement. Disconnected and removed old furnace and then set new one on blocks in its place. Reconnected the gas, electric, PVC vent pipes, and duct-work to new furnace. Installed a new Thermostat and connected it to the Furnace. Run tested the furnace, but will still need a technician start up. The Office will follow up to schedule a technician to return to do the Furnace efficiency startup, which is required for warranty purposes. Thank you for choosing Black-Haak Heating. Please take a moment to fill out our online survey.


Hunter D.

Hunter D. Job Checkin

Performed the start up on a new furnace. No gas leaks detected. Gas and exhaust levels are normal. No CO detected in the air. Venting and electrical components are properly installed. Drain is working. Heat rise was 42 degrees. High limit passed safety test. Unit is operating normally at this time. I replaced the old filter with the 213 upgrade kit. Thank you for choosing Black-Haak! Please take the time to complete our online


Hunter D.

Hunter D. Job Checkin

Installed new gas daikin 2 stage furnace with WiFi stat. All new gas piping, electrical, drain, venting, and low voltage. Furnace tested and running.


Anthony N.

Anthony N. Job Checkin

No heat. Doug said furnace had a burning smell and the blower motor stopped working. I cycled the furnace. Found the exhaust motor and the blower motor are seizing up. It sounds like the blower motor seized up causing the burning smell. I got the furnace running for now. Office will quote price for new exhaust and blower motor. Furnace is 14 years old, average life is about 15 years. The furnace is also in need of maintenance. We may want to get a quote for a new furnace to compare it to the cost of repairs. Dan will call to quote new furnace. Doug would like the 2200 spacegaurd 213 upgrade kit during the furnace replacement.


Hunter D.

Hunter D. Job Checkin

Performed the start up on a new furnace. No gas leaks detected. Gas and exhaust levels are normal. No CO detected in the air. Drain is working. Venting and electrical components are properly installed. High limit passed safety test. Heat rise was 47 degrees. Unit is operating normally at this time. Thank you for choosing Black-Haak! Please take the time to complete our online


Scott K.

Scott K. Job Checkin

1/20/19. Removed old furnace. Installed new daikin single stage furnace. Installed metal to connect furnace to duct. Reconnected electrical and thermostat wiring to new furnace. Connected the pvc to the exhaust and intake on furnace. Ran new drain hose from coil, furnace, and humidifier to floor drain. Installed filter upgrade kit along with a 213 filter. Connected the gas line to furnace. Started furnace and everything is running and draining properly. Thank you for choosing Black-Haak heating for your heating needs.


Evan A.

Evan A. Job Checkin

Installed April air 600 tested and ran humidifier. Went over with home owner operations of the April air 600. Completed a start up on the new Daikin furnace. Set the gas pressure at 3.5”. Adjusted the fan speed to achieve a 50* temperature rise through the furnace. The furnace is up and running efficiently.


Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Gas and exhaust levels are normal. No CO detected in the air. Drain is clear. Heat rise was 42 degrees. We will need to come back and perform a combustion analysis again. I had high CO readings in the exhaust. The air test was okay, but I think it would be in best interest for the customer if we ran another analysis to be safe.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger. Checked and cleaned flame sensor and burners. Ventor motor has some bearing wear. Igniter is worn, but tested ok. Normal levels of CO and XS air in exhaust. No CO found in airstream. System is worn, but operating normal at this. Job complete.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger. Ok. Checked and cleaned burners and flame sensor. Burners were very rusted, but cleaned up ok. Checked ventor motor, ok. Checked for levels of CO and XS air in exhaust. Normal levels found. No CO found in airstream. System operating normal at this time. Job complete.


Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Gas and exhaust levels are normal. No CO detected in the air. Drain is clear. Heat rise was 63 degrees. Unit is operating normally at this time.