N967 Quality Drive
Greenville, WI 54942
920-757-9990

Local Reviews
for kimberly, wi

Rated 5.0 out of 5 stars based on 8 customer reviews

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

friendly and efficient

answered all my questions that made it easy to understand without acting like I was dumb.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

True professionals, knowledgable and and friendly service. I will definitely use their services again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

We had a small emergency with our A/C on a Saturday, during one of the hottest days of the summer, and they came out quickly and fixed everything! Amazing service and professionalism! Highly recommended.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service and very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thanks Evan!!

Evan was in and out in about an hour, and everything went very well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great srvice

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for kimberly, wi

Evan A.

Evan A. Job Checkin

Installed April air 600 tested and ran humidifier. Went over with home owner operations of the April air 600. Completed a start up on the new Daikin furnace. Set the gas pressure at 3.5”. Adjusted the fan speed to achieve a 50* temperature rise through the furnace. The furnace is up and running efficiently.


Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Gas and exhaust levels are normal. No CO detected in the air. Drain is clear. Heat rise was 42 degrees. We will need to come back and perform a combustion analysis again. I had high CO readings in the exhaust. The air test was okay, but I think it would be in best interest for the customer if we ran another analysis to be safe.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger. Checked and cleaned flame sensor and burners. Ventor motor has some bearing wear. Igniter is worn, but tested ok. Normal levels of CO and XS air in exhaust. No CO found in airstream. System is worn, but operating normal at this. Job complete.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger. Ok. Checked and cleaned burners and flame sensor. Burners were very rusted, but cleaned up ok. Checked ventor motor, ok. Checked for levels of CO and XS air in exhaust. Normal levels found. No CO found in airstream. System operating normal at this time. Job complete.


Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Gas and exhaust levels are normal. No CO detected in the air. Drain is clear. Heat rise was 63 degrees. Unit is operating normally at this time.


Hunter D.

Hunter D. Job Checkin

Installed new furnace, and took old one out, hooked up venting,gas, and electrical. No ductwork new furnace went right under cased coil. Ran a new drain line for furnace and A/C. Put a new thermostat on the wall.


Anthony N.

Anthony N. Job Checkin

Was here for a furnace cleaning. Performed preferred customer furnace cleaning. Completed furnace cleaning form. Furnace is running normally at this time. Couldn’t change the battery in the thermostat. The battery is a c cell battery. Office to call to see if the customer would like to order a battery.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Customer stated that furnace would continue to start up and shut down. I cycled system and found that the pressure switch would not stay closed. I checked drain lines and found them full of water. Cleared all drain lines and also pressure switch tubes. Cycled again and the switch is operating normal. Checked heat exchanger, some rusting. Flame sensor and burners were checked and cleaned. Igniter is showing some signs of being worn, but operating normal at this time. Normal levels of CO and XS air in exhaust. No CO found in airstream. System is operating normal at this time. Job complete. Ac and furnace clean and tune.


Julian  D.

Julian D. Job Checkin

Performed furnace clean and tune; started by inspecting the exhaust and intake pvc ensuring all connections were secured, I then removed and cleaned burners along with the flame sensor, Next I cleared out the drain line, I then cycled the system on and checked gas pressures, lastly I performed a combustion test verifying no CO in the airstream as well as replaced the 16x25x1 filter. This system is currently operating normal at this time job complete. Dan F will be out 10/26 at noon for AC second opinion


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Found ventor motor very loud. Bearings are worn. Checked heat exchanger. Found it very rusted. Some indications of cracks forming. Checked for CO in airstream, none found. Normal levels of CO and XS air in exhaust. Vibration from blower motor. System has signs of major water damage due to a pipe that broke above furnace. Furnace and surrounding area was greatly effected by the water, According to the customer. System is worn and future failer is expected, however he system is operating normal at this time. Office to quote ventor motor replacement price on follow up call. Job complete.


Dan E.

Dan E. Job Checkin

Free furnace safety check. Cycled system. Checked heat exchanger, some rusting, no cracks found. Checked and cleaned flame sensor. Checked igniter, some ware but tested ok. Checked gas pressure. Ok. Found indications of small water leak from ventor motor/ transition assembly. Not major at this time, but we will have to monitor it in future. Normal levels of CO and XS air found in exhaust. No CO found in airstream. System operating normal at this time. Job complete.


Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Flame sensor and burners are clean. Heat exchanger looks good. Drain is clear. Combustion analysis test was normal. No CO detected in the air. Unit is operating normal at this time.


Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Flame sensor and burners are clean. Heat exchanger looks good. Drain is clear. Combustion analysis test was normal. No CO detected in the air. Unit is operating normal at this time.


Dan E.

Dan E. Job Checkin

60,000 btu, forced, upflow, HSI, 2ton ac, basement, 12(furnace) 15(ac). Performed package clean and tune; started with the furnace by inspecting and cleaning burners, i then cleaned and tested electrical components, in addition to inspecting heat exchanger for cracks which did fail the powder test, as well as checked gas pressures and ran a combustion test. Then went to the AC and tested the compressor and cleaned out electrical compartment did find the capacitor showing signs of age with rust, we sprayed and cleaned the outdoor coil, and to finish it off we took pressures and temperatures with subooling sitting at 8 degrees and a 10 degrees temp split we sniffed the evap coil and did find indications of a leak. Job complete


Hunter D.

Hunter D. Job Checkin

Performed level 2 AC cleaning. Indications of a leak detected at the indoor coil. However, the refrigerant charge wasn’t bad. Electrical components from the compressor tested good. Condenser coil is clean. Unit is operating normal at this time.