N967 Quality Drive
Greenville, WI 54942
920-757-9990

Local Reviews
for larsen, wi

Rated 5.0 out of 5 stars based on 3 customer reviews

Very pleased with service!

Very professional, did a great job, answered questions.... very happy with the service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, fast, qualify

Couldn't be happier with our decision to use Black Haak for installation of our new air condition system! Great customer service, fast installation (had to quit early one day due to rain, but still finished ahead of time) and the products work just as the salesman said they would.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Furnace service

Did excellent work. Very thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for larsen, wi

Anthony N.

Anthony N. Job Checkin

Performed a first year furnace cleaning. Cleaned the the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Cleaned the drain trap and drain line. Cycled the furnace. Checked the motors for proper operation. Performed furnace combustion test. The furnace is running normally at this time.


Hunter D.

Hunter D. Job Checkin

Completed Gas Furnace replacement. Disconnected and removed old furnace and then set new one on blocks in its place. Reconnected the gas, electric, PVC vent pipes, and duct-work to new furnace. Put a new WiFi Thermostat by the drop. Run tested the furnace, but will still need a technician start up. The Office will follow up to schedule a technician to return to do the Furnace efficiency startup, which is required for warranty purposes. Thank you for choosing Black-Haak Heating. Please take a moment to fill out our online survey.


Anthony N.

Anthony N. Job Checkin

was Here on no heat found the main board to be bad also under additional work replaced igniter and psi switch. Also we are crediting the charges from this morning to his new bill


Julian  D.

Julian D. Job Checkin

Performed furnace start up; customer stated that they would like their humidifier wired into Nest Tstat I ran a new 8 wire for this and spoke with Nest we will have to return to finish the wiring, I then inspected the exhaust and intake PVC ensuring all connections were secured, I then sniffed the gas line for possible leaks, next I cycled the system on and checked gas pressures and did make adjustments on both stages, lastly performed a combustion test verifying no CO in the airstream. This system is currently operating normal at this time. Job complete


Brad G.

Brad G. Job Checkin

Furnace wasn’t heating and I couldn’t read the codes. Cycled furnace. O igniter but the gas came on. 120v to the igniter and igniter is open. Talked to customer about the issue and repair vs replacement. They was tied to get heat on and are planning to replace the furnace early next year. Gave the customer on option of prefoming a cleaning. Replaced th igniter and tested the heat exchanger and preformed a combustion test to insure safety. Everything operating properly. Thanks Brad


Craig W.

Craig W. Job Checkin

Installed Daikin Furnace - M#DM96VE060 S#1805735877 I completed the gas furnace replacement. I disconnected and removed the old furnace. I set the new furnace on blocks and reconnected the electric, gas, pvc venting and duct-work. I ran a new condensate drain line to the floor drain. I installed the customer provided Nest thermostat per their request. I run tested the furnace, but will still need a technician to complete the start up. Thank you for choosing Black-Haak heating. Please take a moment to fill out our online survey.


Craig W.

Craig W. Job Checkin

Completed gas furnace replacement. Disconnected and removed old furnace. Set new furnace on blocks and reconnected the electric, gas, pvc venting and ductwork. Ran a new condensate drain line to the floor drain. Installed customers Nest thermostat per their request. Run tested furnace but will still need a technician start up. Thank you for choosing Black-Haak heating. Please take a moment to fill out our online survey.


Hunter D.

Hunter D. Job Checkin

All registers are installed.


Hunter D.

Hunter D. Job Checkin

Started up new furnace. No gas leaks detected. Combustion analysis test was normal. No CO detected in the airstream. High limit passed safety test. Unit is operating normal at this time.


Hunter D.

Hunter D. Job Checkin

Started up new Daikin gas furnace. No CO detected in the airstream. Combustion analysis test was normal. Fan speeds are good. High limit switch passed safety test. Unit is operating normal at this time.


Craig W.

Craig W. Job Checkin

Completed gas furnace replacement. Disconnected and removed old furnace. Set new furnace on existing box and reconnected the electric, gas, drain, and pvc venting. Installed a new WiFi thermostat and ran a new 6 wire to the furnace. Install is complete but will still need a technician start up. Thank you for choosing Black-Haak heating. Please take a moment to fill out our online survey.


Craig W.

Craig W. Job Checkin

Completed AC replacement. Reclaimed old refrigerant and removed old condenser and coil. Installed a new evaporator coil in the furnace plenum. Set and leveled a new pad outside and placed new condenser on it. Flushed the existing lineset and reconnected to the condenser and coil. Pressurized the lineset to 325 psi with nitrogen to test for leaks and then evacuated to 488 microns. Released charge and did a complete start up procedure. Thank you for choosing Black-Haak heating. Please take a moment to fill out our online survey.


Hunter D.

Hunter D. Job Checkin

Performed AC start up. Added one pound of 410a. Normal readings from gauges. Temp split was 18 degrees. Superheat was 25 degrees. Replaced fuses in the disconnect panel. System is operating normal at this time.


Craig W.

Craig W. Job Checkin

Completed furnace and AC replacement. Disconnected and removed old furnace. Set new furnace on blocks and reconnected the ducts, gas, electric and pvc venting. Ran a new drain line. Reconnected existing thermostat. Test fired furnace but will still need a technician start up. Reclaimed old refrigerant and removed old condenser and coil. Set a new pad outside and placed new condenser on it. Installed new coil in the furnace plenum. Flushed the refrigerant lines and then reconnected them. Filled with 325psi nitrogen to test for leaks and then evacuated to 400 microns. Released charge and did a complete start up procedure. Thank you for choosing Black-Haak heating. Please take a moment to fill out our online survey.


Hunter D.

Hunter D. Job Checkin

Performed level 2 package cleaning. Furnace. Flame sensor and burners are clean. Heat exchanger looks good. Combustion analysis test was normal. No CO detected in the airstream. AC. No leaks detected at the indoor coil. Electrical components tested good. Condenser coil is clean. Refrigerant charge was good, however, I recommend we return next year to keep an eye on it. Temp split was 20 degrees. HVAC system is operating normal at this time.