N967 Quality Drive
Greenville, WI 54942
920-757-9990

Local Reviews
for little chute, wi

Rated 4.8 out of 5 stars based on 6 customer reviews

Great Servive, bet professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very personable, knowledgable, and professional.

Very good experience, high knowledge of products and services. Overall great experience. And would recommend to anyone

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Great communication start to finish!

Did a great job explaining my options, ordering and installing my air conditioner, in a very timely manner. Communication from start to finish was accurate and informative, very helpful in understanding my options. Air conditioner was installed and is working properly. A few years back you installed my furnace, very happy with both installations. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nice guys

  • Overall Experience
  • Quality
  • Price
  • Convenience

awesome technician!

Dan was our technician, and I can't say enough good things about him! He is so personable, and did a great job. He explained things well, and worked hard to make sure I knew what all my options were. He also went out of his way to have me talk to another member of the Black Haak company to see if replacing my furnace would be a better option. Dan understood when we couldn't afford that right now, and didn't push us to go beyond our budget. He was a really great guy!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service person. Alwayso very pleasant custometo service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for little chute, wi

Julian  D.

Julian D. Job Checkin

Performed furnace clean and tune; inspected the exhaust and intake PVC ensuring all connections were secured, removed and cleaned the burners along with the flame sensor, cycled the system on and checked gas pressures, as well as performed a combustion test verifying no CO in the airstream. I did notice the 413 filter used had all broken fins. I am going to leave a 213 filter and we’ll return later with the 213 upgrade kit. Also leaving a #35 water panel for the changeover this spring. This system is currently operating normal at this time. Job complete


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked and cleaned burners and flame sensor, ok. Checked and adjusted gas pressures to maximize efficiency. Checked levels of CO and XS air in exhaust. Normal levels found. No CO found in airstream. System operating normal at this time. Job complete. Office to call in spring for ac clean and tune. Paid.


Julian  D.

Julian D. Job Checkin

Performed furnace start up; inspected the exhaust and intake PVC ensuring all connections were secured we will have to return to replace a section of pvc that is leaking water as well as spray foam the intake and exhaust, I then sniffed the gas line for possible leaks, I did find that the evaporator coil is slanted the wrong way this could cause issues during AC season we’ll follow up with this, I did inspect gas pressures and did adjust it to 3.5InH2O, as well as performed a combustion test verifying no CO in the airstream. This system is currently operating normal and heating at 34 degrees at this time Job complete


Scott K.

Scott K. Job Checkin

2/28/19. Removed old furnace. Installed new daikin furnace. Installed filter upgrade kit along with a 213 filter. Reconnected electrical and thermostat wiring to furnace. Connected pvc to exhaust and intake on furnace. Connected gas piping to furnace. Installed metal to connect furnace to duct. Started furnace. Everything running properly. Thank you for choosing Black-Haak heating for your heating needs.


Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Gas and exhaust levels are normal. No CO detected in the air. Drain is clear. Heat rise was 55 degrees. Unit is operating normally at this time.


Julian  D.

Julian D. Job Checkin

Performed furnace start up; inspected the exhaust and intake PVC ensuring all connections were secured, sniffed the gas line for possible leaks, sniffed the A coil for possible refrigerant leaks, as well as performed a combustion test verifying no CO in the airstream. I did find a substantial amount of dust on the underside of the A coil this could potentially cause issues with the cooling system during the summer as well as put a strain on the furnace during the winter months. This is also an indication that the filter in place is not working the way it should it is allowing dirt/dust to the system I am including a quote for an electronic air cleaner this filter takes place of the current 14x20x1 filter but carries an electronic charge acting like a magnet for those tiny particles that are getting through the current filter. This sytem is currently operating normal at this time and heating at 55 degrees at this time. Job complete


Hunter D.

Hunter D. Job Checkin

2/1/19. Removed old furnace. Installed new 2 stage daikin. Connected pvc to furnace. Reconnected electrical and thermostat wiring to furnace. Hooked gas piping back to new furnace. Installed metal to connect furnace to duct. Ran new drain hose from furnace and coil to floor drain. Thank you for choosing Black-Haak heating for your heating needs.


Anthony N.

Anthony N. Job Checkin

Was here for a furnace cleaning. Performed preferred customer furnace cleaning. Completed furnace cleaning form. The furnace is running normally at this time.


Julian  D.

Julian D. Job Checkin

Replaced door switch under warranty. I cycled the system on to verify operations. System is now operating normal. Job complete


Dan E.

Dan E. Job Checkin

Unit heater x2 clean and tune. Cycled system in RV bay. Disassembled unit. Checked all sides of heat exchanger. Checked and cleaned sparker. Cleaned heat exchanger, all wall surfaces, and electrical components. Checked gas valve and venting, ok. Cleaned and adjusted fins per customer to maximize heating throughout storage unit. System operating normal at this time. Found one missing fastening screw for bottom plate. Plate appears secure at this time. Changed batteries in thermostat. No CO found in airstream. Cycled unit in other storage unit. Disassembled system. Checked all sides of heat exchanger, no rust or cracks found. Cleaned all reachable interior and exterior surfaces. Adjusted fins to maximize heating throughout unit. Checked gas valve and electrical components, ok. Changed batteries in thermostat. Found no CO in airstream around unit. Found one large dent in bottom of unit . Pic included on file. Both systems are operating normal at this time. Job complete.


Evan A.

Evan A. Job Checkin

Time Delay Relay for UH was replaced. I reconnected the electrical and cycled the unit heater. The unit heater is heating normally. He would like some prices quoted to have maintenance done on both of his unit heaters.


Evan A.

Evan A. Job Checkin

Time Delay Relay for UH was replaced. I reconnected the electrical and cycled the unit heater. The unit heater is heating normally. He would like some prices quoted to have maintenance done on both of his unit heaters.


Hunter D.

Hunter D. Job Checkin

12/7/18. Removed old furnace. Installed new temp star furnace. Connected new metal on top to attach furnace to duct work. Reconnected the electrical and thermostat wires. Hooked the venting back up to furnace. Ran new drain line from coil and furnace to drain hose that was going through wall. Hooked the gas back up to the furnace. Started furnace and it is running and draining as it should. Thank you for choosing Black-Haak for your heating needs.


Dan E.

Dan E. Job Checkin

No heat at the time I arrived. Cycled system. System would not light up due to obstruction in venting. Tryed to check intake venting with camera, could not find obstruction. Removed intake venting and vented intake to basement. System fired as normal. Checked heat exchanger, found it very rusted and damaged. Cracks starting to form. Ventor motor bearings are very worn. Igniter is in very poor condition. Burners are very rusted and damaged. System is in very poor shape. Checked CO and XS air in exhaust. XS air is high at 198. Clogging secondary heat exchanger.


Anthony N.

Anthony N. Job Checkin

Was here for a furnace cleaning. Performed preferred customer furnace cleaning. Completed furnace cleaning form. Furnace is running normally at this time. The customer would like a call in the spring for a possible air conditioning cleaning.