N967 Quality Drive
Greenville, WI 54942
920-750-7138

Local Reviews
for sherwood, wi

Rated 5.0 out of 5 stars based on 21 customer reviews

Gerar service

Did am excelente Job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exceptional service and personnel.

Hunter was very knowledgeable, excellent communication skills and a pleasure to work with

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Very profresional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Smoke alarm issue

Pleased with how quickly you came....and my dog is very happy he isn't hearing that noise any more! Service was professional and thorough. Mike checked the other detectors as well and took out the locking pin so that I can change the batteries myself if need be.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great technicians

I would recommend Black Haak. They are very professional, helpful and through. Julienne, Evan Devin and Dan were all great! Thanks for the great work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

GREAT SERVICE

EVERYTHING WAS NEAT AND CLEAN, EXPLAINED EVERYTHING

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Servicewe both

We both agree that Julian is a great representative of Black Haak. He was polite, efficient, and very knowledgeable. We would be pleased to have him service our furnace & fireplace on a yearly basis.

  • Overall Experience
  • Quality
  • Price
  • Convenience

installers were very polite and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

AC tuneup

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Black-Haak installed my furnace and AC when I built my house. I've had them maintain and service my system ever since and have always been very pleased with their expert knowledge and quality of service. Their pricing is very fair and they are very honest up-front about the cost of things. I know I can rely on them and will be a lifetime customer! The technicians are VERY friendly and helpful, they are great to work with!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Bill and Tim did a great job doing some correction work on our installed HVAC system. They were professional, personable, conscientious.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Annual Maintenance

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

My questions were answered and then some !

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service tech was very informative and polite.

Dan did a very nice job and answered any questions that I had.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sherwood, wi

Dan E.

Dan E. Job Checkin

Sorry for the confusion on this. Please give a call with any questions! Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked and tested igniter, tested normal. Checked and adjusted gas pressures to maximize efficiency. Checked and tightened electrical connections and clamps. Cleared drain lines. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. System was very dirty and it is recommended for yearly maintenance on this equipment. Unit operating normal at this time. Job complete.


Anthony N.

Anthony N. Job Checkin

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time. Changed the furnace filter and the hepa filter.


Dan E.

Dan E. Job Checkin

Fireplace clean and tune. Cycled system. Cleaned walls, log, and glass. Cleaned ignition system. Re lit pilot and cycled system. Unit operating normal at this time. Job complete.


Kody W.

Kody W. Job Checkin

I performed the furnace clean and tune. The furnace is operating properly. I left a spare filter as well. We will return to complete the air conditioner cleaning in the spring.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked and tightened electrical connections and clamps. Cleared drain line. Checked and adjusted gas pressures to maximize efficiency. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. System operating normal at this time. Job complete.


Anthony N.

Anthony N. Job Checkin

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.


Hunter D.

Hunter D. Job Checkin

I reset the filter alert on the thermostat. Customer purchased a fireplace and AC cleaning. We will call to schedule.


Hunter D.

Hunter D. Job Checkin

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger is heavily rusted and chipped, however, no cracks located at this time. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 42°. Unit is heating properly.


Dan E.

Dan E. Job Checkin

System problem. Customer stated that the furnace was short cycling. System would turn on for a min then cycle off. It repeats this over and over. This has been happening for the last few weeks. I checked filter. Filter was a bit dirty, but ok. Cleared drain line and checked drain trap. Cleared pressure switch tubing. No obstructions found. Cycled system and unit failed after a min with a pressure switch code. Removed intake venting pipe and cycled again. System ran for over 15 mins. Recommend furnace clean and tune. Recommend leaving venting off until cleaning. System operating at this time. Job complete.


Hunter D.

Hunter D. Job Checkin

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 41°. Unit is heating properly.


Erika  J.

Erika J. Job Checkin

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Furnace working well at this time. Please renew tuneups to maintain your warranty


Erika  J.

Erika J. Job Checkin

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Furnace working well at this time. Please renew tuneups To maintain your warranty


Anthony N.

Anthony N. Job Checkin

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time. We will be returning in the air conditioner cleaning.


Anthony N.

Anthony N. Job Checkin

Need install crew to return to rerun air intake at furnace. Currently above burners and gas valve. Move it to side of furnace. Upon arrival the furnace would not light. Found that the gas valve was bad due to water damage. Had the office run out the new gas valve and replaced it under a warranty. Performed a preferred customer furnace cleaning. Cleaned the unit. Cycled the furnace. Checked the gas valve and performed a furnace combustion test. The furnace is running normally at this time.


Mike W.

Mike W. Job Checkin

Looked at fans that were loose. Found both fans had loose screws. Put washers on the screw heads so they wouldn’t pull through the bracket slots and tightened the screws for both fans.