Now if you could just make it free, you would be perfect, but probably out of business.
We had Jeramiah and I love that guy! Very helpful and always asks if I have any questions which I did and he answered. Love the fact that all the technicians that come to my home always put on shoe covers! I appreciate that!
What a great team you have at B-H. I really appreciate every step you took in solving my problem with my Generac generator during the storm.
Called and instructed on how to put in filter. Job complete.
Furnace clean and tune. Cycled system. Checked filter. Found filter very clogged and dirty. Removed and customer will get new filter. Checked, removed, and cleaned burners and flame sensor. Checked heat exchanger, found all chambers to have some rust and corrosion. No cracks found at this time. Burners were very corroded. Sparker cleaned and checked. Found evidence of water leaking from ventor gasket. Did not find cracks in transition assembly. Ventor motor bearings sound intact and not worn at this time. Cleared drain line. Cleaned and checked blower compartment. System is 5 years old and operating normal at this time. Job complete. Filter is a 20x25x6. A 20x25x4 could be used. Set up for an air bear filter. Office to schedule ac clean and tune in spring.
Fireplace clean and tune. Cycled system. Removed grate and glass from unit. Removed logs and cleaned. Checked and cleaned electronic sparker. Cleaned surround and burner plate. Placed new embers and removed old ones, cleaned under unit and checked electrical components. Cleaned glass and outside of unit. Reassembled system and fired. System operating normal at this time. Job complete.
Disconnected burnt up parts to turn on regular power on. Transferred power to utility power. Generator under warranty.
Performed AC start up; connected low voltage wires to terminal strip and to contactor on the condenser, released nitrogen and pulled vacuum to 360 microns, released compressor charge and removed a half pound of R410, superheat is at 16 degrees with 10 degrees of sub cooling with a 17 degree temp split. This system is currently operating normal at this time job complete. Inspected Tstat to see if we could connect to WiFi its a Honeywell prestige which will need a red link gateway
Performed furnace start up; started by setting up the humidifier at the prestige thermostat, I then went and inspected the exhaust and intake pvc ensuring all connections were secured, I then did a leak search on the gas line, I cycled the system on and checked gas pressures and did make adjustments on both stages, lastly performed a combustion test verifying no CO in the airstream. This system is currently operating normal and heating at 58 degrees at this time job complete.
Service call for the furnace not heating. Replaced the faulty thermostat.
Installed a Magneto kit for the Generac generator.