N967 Quality Drive
Greenville, WI 54942
920-757-9990

Local Reviews
for winneconne, wi

Rated 5.0 out of 5 stars based on 7 customer reviews

timely good service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

COURTEOUS SERVICE

I AM SATISFIED WITH A JOB WELL DONE BY RESPECTFUL EMPLOYES

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

On time service

Tech was on time, very curtious, wore clean uniform and was very knowledgeable. Fixed issue in a very short time ,

  • Overall Experience
  • Quality
  • Price
  • Convenience

good service but don't understand why I was charged for A/C checkout

I didn't`t expect a charge to checkout the A/C because it wasn't`t checked out when it was installed because we were not home until late Aug last year and thought it would be checked out w/o charge this year. Dan Gross

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic service and quality

  • Overall Experience
  • Quality
  • Price
  • Convenience

Promp service

Technicians were on time and completed the work in a timely manor and cleaned nicely

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for winneconne, wi

Mike W.

Mike W. Job Checkin

Troubleshot circuit being overloaded. Found that the circuit white all equipment running would pull roughly 35A. We divided the equipment up between three different circuit ps in the basement in order to alleviate the excessive current draw. After the equipment was divided the current draw among the three circuits never reached above 15A.


Anthony N.

Anthony N. Job Checkin

Performed preferred customer air conditioning cleaning. Checked over the air conditioner. Electrical is good. Tested the refrigerant levels. The refrigerant levels are good. The air conditioner is running normally at this time.


Anthony N.

Anthony N. Job Checkin

Performed preferred customer furnace cleaning. Did not find any issues with the furnace. The furnace is running normally at this time. The customer would like to get the air conditioner cleaned and has upgraded to the package. Office to please call to set up an appointment to clean the air conditioner.


Dan E.

Dan E. Job Checkin

Ac clean and tune. Checked and replaced filter. Cleared drain line. Cycled system. Checked and cleaned electrical compartment. Tested fan motor and compressor, both tested fine. Used coil cleaner on condenser. Hooked up gauges and checked pressures and temps. Pressures and temps were ok. Checked split. System operating normal at this time. Quote given for electronic air cleaner. Job complete.


Kody W.

Kody W. Job Checkin

Dennis replaced the WiFi router for the house. The thermostat need to be connected to the new router. I went through the WiFi setup. Connected thermostat to the WiFi. Cycled the system. Everything is operating properly.


Kody W.

Kody W. Job Checkin

I replaced the condenser fan motor on the small rooftop unit. Wired motor and cycled the unit. The rooftop is now cooling properly. The north unit wasn’t cooling after we replaced the main boards. I found there wasn’t a call for cool at the unit. I went around and turned all the thermostats down and there still wasn’t a call for cooling. I inspected the central control center and tried to find a manual to see how it works. Couldn’t find a manual. I wired up a temporary thermostat on the first floor but the unit still wouldn’t cool. I traced the thermostat wiring in the rooftop and found the previous company had a thermostat wired and set in the return duct. The thermostat was set to auto heat/cool. I adjusted the cool set point to 70 and the heat set point to 65 for now. The unit is now cooling. We need to get manuals for the north rooftop and the central control center. Also randy wants us to quote a different zone / control system. Office will call to schedule that.


Kody W.

Kody W. Job Checkin

I replaced the condenser fan motor on the small rooftop unit. Wired motor and cycled the unit. The rooftop is now cooling properly. The north unit wasn’t cooling after we replaced the main boards. I found there wasn’t a call for cool at the unit. I went around and turned all the thermostats down and there still wasn’t a call for cooling. I inspected the central control center and tried to find a manual to see how it works. Couldn’t find a manual. I wired up a temporary thermostat on the first floor but the unit still wouldn’t cool. I traced the thermostat wiring in the rooftop and found the previous company had a thermostat wired and set in the return duct. The thermostat was set to auto heat/cool. I adjusted the cool set point to 70 and the heat set point to 65 for now. The unit is now cooling. We need to get manuals for the north rooftop and the central control center. Also randy wants us to quote a different zone / control system. Office will call to schedule that.


Anthony N.

Anthony N. Job Checkin

Was here for a package cleaning. Performed preferred customer furnace clean and check. Completed furnace cleaning form. Furnace is running normally at this time. Performed preferred customer air conditioning cleaning. Completed air conditioning cleaning form. Air conditioner is running normally at this time.


Travis W.

Travis W. Job Checkin

Installed unit heater in garage. Vented through the roof per customer request. Ran flashield from main line inside house. Checked for leaks and relit all appliances.


Anthony N.

Anthony N. Job Checkin

Was here for a furnace cleaning. Performed preferred customer furnace cleaning. Completed furnace cleaning form. Furnace is running normally at this time.


Corey J.

Corey J. Job Checkin

Replaced the voltage regulator.


Brad G.

Brad G. Job Checkin

Performed a cleaning and tune-up on the geothermal unit, replaced a contactor, and eliminated a noise in the system.


Brad G.

Brad G. Job Checkin

geothermal heating


Brad B.

Brad B. Job Checkin

Installed a new heat light/vent.


Anthony N.

Anthony N. Job Checkin

air conditioner