Tech was on time, very curtious, wore clean uniform and was very knowledgeable. Fixed issue in a very short time ,

  • Overall Experience
  • Quality
  • Price
  • Convenience

good service but don't understand why I was charged for A/C checkout

I didn't`t expect a charge to checkout the A/C because it wasn't`t checked out when it was installed because we were not home until late Aug last year and thought it would be checked out w/o charge this year. Dan Gross

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic service and quality

  • Overall Experience
  • Quality
  • Price
  • Convenience

Promp service

Technicians were on time and completed the work in a timely manor and cleaned nicely

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for winneconne, wi

Hunter D.

Hunter D. Job Checkin

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 42°. Unit is heating properly.


Evan A.

Evan A. Job Checkin

I replaced the main board on the furnace. Turned power back on to the furnace and tested operation. Everything is working normally. I set the thermostat down to 68* and turned the thermostat off because there’s a few windows open in the home. The office will follow up for payment. Thank you for choosing Black-Haak, please take a moment to fill out our online survey.


Anthony N.

Anthony N. Job Checkin

Installed new IBC boiler and indirect water heater. Added cleaner to the old boiler to clean out the system. Drained old boiler and moved piping over to the new boiler. Install new pumps and components. Install 14ft of baseboard and move the other one. Fill and purge the system and prefom start up. Hook the new boiler up the the WiFi. System is running and operating properly at this time. Thanks Brad If you could take a few mins and fill out a quick survey I would greatly appreciate it.


Hunter D.

Hunter D. Job Checkin

Performed the new furnace and AC start up. Furnace: No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. All registers are installed. AC: I added one pound of R410A refrigerant. Pressures stabilized. Weather conditions made the charge a little hard to do, however, everything is running as it should. All units are heating and cooling properly.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Removed and cleaned burners and flame sensor, both ok. Checked and adjusted gas pressures to maximize efficiency. Checked electrical connections and clamps. Checked levels of CO and XS air in exhaust. Both levels are normal. No CO in airstream. System operating normal at this time. Job complete. Furnace and ac clean and tune


Mike W.

Mike W. Job Checkin

Troubleshot circuit being overloaded. Found that the circuit white all equipment running would pull roughly 35A. We divided the equipment up between three different circuit ps in the basement in order to alleviate the excessive current draw. After the equipment was divided the current draw among the three circuits never reached above 15A.


Anthony N.

Anthony N. Job Checkin

Performed preferred customer air conditioning cleaning. Checked over the air conditioner. Electrical is good. Tested the refrigerant levels. The refrigerant levels are good. The air conditioner is running normally at this time.


Anthony N.

Anthony N. Job Checkin

Performed preferred customer furnace cleaning. Did not find any issues with the furnace. The furnace is running normally at this time. The customer would like to get the air conditioner cleaned and has upgraded to the package. Office to please call to set up an appointment to clean the air conditioner.


Dan E.

Dan E. Job Checkin

Ac clean and tune. Checked and replaced filter. Cleared drain line. Cycled system. Checked and cleaned electrical compartment. Tested fan motor and compressor, both tested fine. Used coil cleaner on condenser. Hooked up gauges and checked pressures and temps. Pressures and temps were ok. Checked split. System operating normal at this time. Quote given for electronic air cleaner. Job complete.


Kody W.

Kody W. Job Checkin

Dennis replaced the WiFi router for the house. The thermostat need to be connected to the new router. I went through the WiFi setup. Connected thermostat to the WiFi. Cycled the system. Everything is operating properly.


Kody W.

Kody W. Job Checkin

I replaced the condenser fan motor on the small rooftop unit. Wired motor and cycled the unit. The rooftop is now cooling properly. The north unit wasn’t cooling after we replaced the main boards. I found there wasn’t a call for cool at the unit. I went around and turned all the thermostats down and there still wasn’t a call for cooling. I inspected the central control center and tried to find a manual to see how it works. Couldn’t find a manual. I wired up a temporary thermostat on the first floor but the unit still wouldn’t cool. I traced the thermostat wiring in the rooftop and found the previous company had a thermostat wired and set in the return duct. The thermostat was set to auto heat/cool. I adjusted the cool set point to 70 and the heat set point to 65 for now. The unit is now cooling. We need to get manuals for the north rooftop and the central control center. Also randy wants us to quote a different zone / control system. Office will call to schedule that.


Kody W.

Kody W. Job Checkin

I replaced the condenser fan motor on the small rooftop unit. Wired motor and cycled the unit. The rooftop is now cooling properly. The north unit wasn’t cooling after we replaced the main boards. I found there wasn’t a call for cool at the unit. I went around and turned all the thermostats down and there still wasn’t a call for cooling. I inspected the central control center and tried to find a manual to see how it works. Couldn’t find a manual. I wired up a temporary thermostat on the first floor but the unit still wouldn’t cool. I traced the thermostat wiring in the rooftop and found the previous company had a thermostat wired and set in the return duct. The thermostat was set to auto heat/cool. I adjusted the cool set point to 70 and the heat set point to 65 for now. The unit is now cooling. We need to get manuals for the north rooftop and the central control center. Also randy wants us to quote a different zone / control system. Office will call to schedule that.


Anthony N.

Anthony N. Job Checkin

Was here for a package cleaning. Performed preferred customer furnace clean and check. Completed furnace cleaning form. Furnace is running normally at this time. Performed preferred customer air conditioning cleaning. Completed air conditioning cleaning form. Air conditioner is running normally at this time.


Travis W.

Travis W. Job Checkin

Installed unit heater in garage. Vented through the roof per customer request. Ran flashield from main line inside house. Checked for leaks and relit all appliances.


Anthony N.

Anthony N. Job Checkin

Was here for a furnace cleaning. Performed preferred customer furnace cleaning. Completed furnace cleaning form. Furnace is running normally at this time.