Steam Leak

Came back to tighten a union that started leaking after original repair. While on site he went to the extra effort to install additional screws and foil tape to fix a connection on the discharge of the air handler. Much appreciated!

  • Overall Experience
  • Quality
  • Value
  • Convenience

👍

  • Overall Experience
  • Quality
  • Value
  • Convenience

Quality at its finest.

Great company and best in class service. Keith was knowledgeable, professional and personable.

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great as always

Always great

  • Overall Experience
  • Quality
  • Value
  • Convenience

Excellent communication awesome attention to detail fast and reasonable.

Both technicians were knowledgeable with the air handler they were working on. Got in there got the job done just as I asked and got it up and running 3 days before another company could even try to get out onsite.

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great Service.

Blue Hat Mechanical has always done a great job and service when ever we need them to come out and service our machines.

  • Overall Experience
  • Quality
  • Value
  • Convenience

Job Locations

Matt P.

Matt P. Job Checkin


JD L.

JD L. Job Checkin

Troubleshoot and Repair Furnace


Keith H.

Keith H. Job Checkin


Matt P.

Matt P. Job Checkin


Chad B.

Chad B. Job Checkin

Inoperable Deficiency for Kitchen BHM06392 Beverage-Air SPE72-30M 12004256: On site, customer advised cooler was not operating - Plugged unit in and checked operation - Applied gauges and found system nearly empty - Verified leak is from evaporator coil - Customer wants to charge system - Unit is leaking to fast to top off refrigerant Suggested for Kitchen BHM06392 Beverage-Air SPE72-30M 12004256: Arrived to do quotes repair for 3 door reach in. •disassembled panes and shelving to expose evaporator. Also removed top doors and cold bin. •uninstalled and removed evaporator. •cleaned evaporator area and condensate drain pan •removed old cap tube and filter drier •piped in and mounted new evaporator and cap tube. New evaporator about 1/2” shorter than existing one. New mounting holes needed to be fixed. • replaced filter drier. Added time due to newer one being different than one existing and had to rework the copper plumbing. • pressure tested to 150 psig for 20 minutes • dehydrate


Matt P.

Matt P. Job Checkin


Bryce L.

Bryce L. Job Checkin


Chad B.

Chad B. Job Checkin

Suggested for RTU9 BHM07394 Trane 110510670L: Completed full heat pm •Verified operations prior to starting pm •replaced air filters • verified no trouble Alarm •inspected electrical components •could not check or adjust gas pressure due to manifold being installed incorrectly. The port is pressed against the bottom of the unit. •ran in high fire and inspected for proper blue flame •ran in low fire and inspected for blue flame Unit is running normally at this time. Suggested for RTU 17 lower roof BHM02828 Roof Top Unit Trane TSC072E4R0A0VH0B1A1B00000 110510754L: Completed full heat pm •Verified operations prior to starting pm •replaced air filters • cleared condensate trap •tightened belt •inspected electrical components •measured (3.1” wc) gas pressure and adjusted to 3.5” wc. Unit is running normally at this time. Suggested for RTU10 BHM07377 Trane 110510828L: Completed full heat pm •Verified operations prior to starting pm •replaced air filters • cleared condensa


Keith H.

Keith H. Job Checkin


Chad B.

Chad B. Job Checkin

Suggested for RTU9 BHM07394 Trane 110510670L: Completed full heat pm •Verified operations prior to starting pm •replaced air filters • verified no trouble Alarm •inspected electrical components •could not check or adjust gas pressure due to manifold being installed incorrectly. The port is pressed against the bottom of the unit. •ran in high fire and inspected for proper blue flame •ran in low fire and inspected for blue flame Unit is running normally at this time. Suggested for RTU 17 lower roof BHM02828 Roof Top Unit Trane TSC072E4R0A0VH0B1A1B00000 110510754L: Completed full heat pm •Verified operations prior to starting pm •replaced air filters • cleared condensate trap •tightened belt •inspected electrical components •measured (3.1” wc) gas pressure and adjusted to 3.5” wc. Unit is running normally at this time. Suggested for RTU10 BHM07377 Trane 110510828L: Completed full heat pm •Verified operations prior to starting pm •replaced air filters • cleared condensa


Curtis B.

Curtis B. Job Checkin


Chad B.

Chad B. Job Checkin

Suggested for detail shop BHM05548 gas pack carrier 48GS-018040301 1803G51187: Completed full heat pm •Verified operations prior to starting pm •replaced air filter •inspected electrical components •measured (3.1” wc) gas pressure and adjusted to 3.5” wc. Unit is running normally at this time. Suggested for Front Offices (detail shop) BHM2829 RTU Carrier 48tcea07a2a6a0a0a0 3617c77481: Completed full heat pm •Verified operations prior to starting pm •replaced air filter •inspected electrical components •measured (3.1” wc) gas pressure and adjusted to 3.5” wc. Unit is running normally at this time.


Chad B.

Chad B. Job Checkin

Inoperable Deficiency for Break room BHM07564 Frigidaire Fccm201rfb2 Wa11903350: Could not complete pm at this time due to unit not running


Chad B.

Chad B. Job Checkin

Inoperable Deficiency for Scotsman MDT5N40A-1J BHM00798 11021320012394 3rd Floor Break Room: Arrived to do pm of break room equipMeant. I was escorted to 3rd floor and found ice machine off. Customer informed me that no one has been in the office for 3 months. I found the unit not receiving power. Checked receptacle and I had zero volts. Could not access electrical closet at this time. Customer didn’t have access. Inoperable Deficiency for Break room BHM07564 Frigidaire Fccm201rfb2 Wa11903350: Arrived to complete pm. Customer informed me that unit has been off for 3 months with door open. I turned it on and only the light comes on. I received and okay to investigate and verified incoming power at receptacle. The thermostat was set to off and once I set to 7 (out of 10) nothing came on. Checked voltage to compressor (0 volts), checked voltage to evaporator fan (0). It appears at this time that the thermostat in the evaporator needs replaced due to failure. I advised customer and she


Curtis B.

Curtis B. Job Checkin