2430 Reliance Ave
Apex, NC 27539
919-773-9223

Local Reviews

Rated 4.9 out of 5 stars based on 706 customer reviews

.

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great service

It’s okay awesome

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great service / Very thorough

Technician was very knowledgeable and friendly.

  • Overall Experience
  • Quality
  • Value
  • Convenience

Excellent

Curtis showed up and went right to work.. Polite and informative

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great job as always!

  • Overall Experience
  • Quality
  • Value
  • Convenience

Tech was very professional and knew what to do

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great Service very knowledgeable

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great Service very knowledgeable

Great all around!

  • Overall Experience
  • Quality
  • Value
  • Convenience

Very Knowledgeable

  • Overall Experience
  • Quality
  • Value
  • Convenience

Great Service and Great guy

  • Overall Experience
  • Quality
  • Value
  • Convenience

Job Locations

Curtis B.

Curtis B. Job Checkin


Chad B.

Chad B. Job Checkin

Deficiency for Kitchen BHM08658 AHU Carrier NA NA: Arrived and checked in with Christopher and inspected old thermostat and equipment that it controls. Replaced thermostat with t6 pro and setup parameters. Both condenser units are controlled by one tstat behind the counter. Removed panels and inspected evaporator and blower motor. Condenser on right side (BHM 08660 *SECOND STAGE*)has a vibration that can be seen and felt. It appears as though the vibration is from the condenser fan motor or fan blade not balanced. Vibration and rattling is more of an annoyance instead of a mechanical problem. It’s possible it could be an early sign of fan motor starting to go bad. Left side condenser (BHM08659 *FIRST STAGE*): annoyance rattle is present. 32 degree air split across the condenser coil. Units are working normally and no noticeable issues that would prevent operation other than condenser fan motors bearings possibly going bad. Deficiency for center roof BHM07306 hoodmart hmex36b rf


Bryce L.

Bryce L. Job Checkin

Troubleshoot and Repair HVAC Unit


Curtis B.

Curtis B. Job Checkin

Troubleshoot and Repair HVAC Equipment


Bryce L.

Bryce L. Job Checkin

Troubleshoot and Repair HVAC Equipment


David L.

David L. Job Checkin

Refrigeration Emergency Service Call


Jared G.

Jared G. Job Checkin

This quote is for all labor and materials to  perform the following: Disconnect, remove  and disposal of existing RTU #1. Set adapter curb for new unit on existing roof curb. Set new unit. New unit submittal attached to this quote. Reconnect existing gas piping and electrical. Start up and verify proper operation. Provide test and balance, to be performed by sub contractor. We Have Included: City Permit We Have Excluded: Any needed permits from RDU port authorities. Any work not specifically noted above. Controls work. Any seismic restraints and/or hurricane straps. Structural roof load sign-off. Connection of smoke detectors to alarm panel and power. Payment Terms: 50% deposit required prior to ordering equipment for job 50% due upon substantial completion


David L.

David L. Job Checkin

Troubleshoot and repair refrigeration equipment.


Bryce L.

Bryce L. Job Checkin

Troubleshoot and Repair HVAC Equipment


David L.

David L. Job Checkin

HVACR Service Call


Curtis B.

Curtis B. Job Checkin

Perform Planned Maintenance on HVAC Equipment


David L.

David L. Job Checkin

Troubleshoot and repair line coolers.


David L.

David L. Job Checkin

Troubleshoot and repair line coolers.


David L.

David L. Job Checkin

HVACR and HVAC Service Call


Chad B.

Chad B. Job Checkin

Inoperable Deficiency for Zone 3 condensing unit BHM09141 Split System Trane TWA073D30RAA 11113U2BYA: BHM09141 Call was for no cooling zone 3 Turned tstat on to call for cooling. Found unit on the roof was cooling but the compressor had a weird whirring sound every now and then. The compressor windings opened and the pressures equalized. The fan was still spinning. And the unit is still calling for cooling. The compressor came back on and I checked the amp draw. The ampdraw was fluctuating up and down from 27 to 38 amps. The RLA for the compressor is only 22 amps. The compressor has internal problems and needs to be replaced Suggested for Zone 3 condensing unit BHM09141 Split System Trane TWA073D30RAA 11113U2BYA: Arrived to replace compressor and filter drier on zone 3 rtu. This is a quoted job fro, previous visit. I arrived and checked in then went to the roof and pulled 17 pounds of r410a out of unit. I cut the discharge and suction lines. Then I remove the fan and top of unit