Casey L.

Casey L. Job Checkin

Replaced condensate pump on server room mini split system. Replaced with blue diamond condensate pump. Checked operation of the pump. Unit is currently back up and running at this time.


Casey L.

Casey L. Job Checkin

System- RTU 5 Approx Age of System: Refrigerant Type- R410a Metering Device- TXV Outdoor Fan FLA- 1.67/1.69 Compressor RLA-5.25/5.31 Contactor Voltage-486/26 Capacitor Rating-9.62/9.51 Indoor Return Dry Bulb Temp-71 Supply Temp-52 Temperature Difference-19 Required Difference-16 Blower FLA- 3.76 Filter Sizes – 18x18x2 (6) Changed Filters – Yes Blew out drain line: No Returned tstat to original settings: Yes Unit operational; prior to leaving: Yes Notes- Scheduled next tune up date: System- RTU2 Approx Age of System: 3 years Refrigerant Type- R410a Metering Device- TXV Outdoor Fan FLA- 1.67/1.66 Compressor RLA-5.46/5.39 Contactor Voltage-482/26 Capacitor Rating-9.92/9.86 Indoor Return Dry Bulb Temp-74 Supply Temp-56 Temperature Difference-18 Required Difference-16 Blower FLA- 3.78 Filter Sizes – 18x18x2 (6) Changed Filters – Yes Blew out drain line: No Returned tstat to original settings: Yes Unit operational; prior to leaving: Yes N


Henry M.

Henry M. Job Checkin

AC Diagnostic System:server room Filter Size(s) daikin mini split filters Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes: Upon arrival,checked in with Rich and he directed me to the server room. Located mini split unit. And found float switch had shut system off and was actually stuck on the top not letting system come back on. Got the float un stuck and filled with water. Pump came on but was not pumping water past the siphon. While putting system back together lower pump and shortened the length of tubing between pump and siphon and pump started to drain water normally and stopped. Once the float activation switch lowered again. Explained that if this is an ongoing issue, recommend installing larger capacity condensate pump to avoid further issues. Temperature split is currently 18.6 degrees between return and supply air. System is operational Before departure and also tested with water 3 times to make sure pump was actually draining water and


Renee S.

Renee S. Job Checkin

PURCHASE ORDER 28004 COMMERCIAL PMA PLUS 11 UNITS


Casey L.

Casey L. Job Checkin

System- Downstairs Approx Age of System: 3 years Refrigerant Type- R410a Metering Device- TXV SP/HP: 102/242 SLT/LLT:41/72 VSAT/LSAT-33/81 Superheat/Subcool-8/9 Outdoor Entering Air Temp- 73 Outdoor Fan FLA- 1.13 Compressor RLA/LRA- 10.69/152.7 Contactor Voltage- 243/24 Capacitor Rating- 68.18/7.28 Indoor Return Dry Bulb Temp- 71 Supply Temp- 52 Temperature Difference- 19 Required Difference- 16 Filter Sizes – 20x30x1,12x24x1 Changed Filters – No. filters are clean Blew out drain line: Yes Notes- Found starting amperage exceeds the manufacturer spec. We currently have a starting amperage of 152.7 and the unit is rated for 135. I recommend adding start capacitor to assist in reducing the starting amperage and help extend the life of the compressor. . . . . . . . . . System- Upstairs Approx Age of System: 3 years Refrigerant Type- R410a Metering Device- TXV SP/HP: 118/245 SLT/LLT: 52/76 VSAT/LSAT-40/82 Superheat/Subcool- 12/8 Outdoor Entering Air Temp- 73 Outdoor


Casey L.

Casey L. Job Checkin

Unit: RTU 10 Replaced the low ambient pressure switch on the high pressure side of the line set. Tested to make sure the fan would kick on after 450 psi and cut out at 250 psi. Low ambient switch is operating as it should at this time. Power has been restored to the unit after repair. Unit has been returned to operational state.


Casey L.

Casey L. Job Checkin

System: RTU 1 Approx. Age of System: Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass/0 ppm Airside CO: pass or fail/return 0 ppm supply 0 ppm Flue gas CO: pass or fail/22 ppm Ignition and Combustion Delayed ignition: no Flame disturbance: no Flame discoloration: no Motor Amperages and Capacitors Blower motor FLA: 1.70 Induced draft/combustion blower motor FLA: 0.31 Capacitor(s): pass or fail/mfd Temperature Rise Rated: 30-60 Actual: 41 Static Pressures Blower speed/cfm: RP 0.46 /SP 0.18 TESP: Safety Controls Primary limit test: pass Filter sizes: Changed filters: yes or no Scheduled next tune up date: Notes: ________________________________________ System: RTU 4 Approx. Age of System: Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass or fail/0 ppm Airside CO: pass/r


Larry W.

Larry W. Job Checkin

Heater has a burning smell. Heating repair and maintenance tune up. Diagnose and perform annual heater maintenance service plan on Ruud heating system. Clear drain lines and check furnace on 11 year old HVAC system. Heater maintenance complete which will help lower heating cost for this residential customer. Evaporator coil is leaking. Recommend replacement evaporator coil, leak repair, or new Comfortmaker air conditioning system. Heating system is now ready for cooler weather.


Mark M.

Mark M. Job Checkin

Perform cool tuneup on comfort club member’s Bryant Furnaces.


Olech G.

Olech G. Job Checkin

Performing a heat tune up x 2 on 2 Bryant systems


Olech G.

Olech G. Job Checkin

Performing a heat tune up x 2 on 2 Bryant systems


Olech G.

Olech G. Job Checkin

Performing a heat tune up x 2 on 2 Bryant systems


Olech G.

Olech G. Job Checkin

Performing a heat tune up x 2 on 2 Bryant systems


Olech G.

Olech G. Job Checkin

Performing a heat tune up x 2 on 2 Bryant systems


Olech G.

Olech G. Job Checkin

Performing a heat tune up x 2 on 2 Bryant systems