Wonderful service

The company has the best people and they explain everything so you understand. Always on time and ready to work. I’d recommend them to anyone.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service.

We appreciated the time and in depth look at out cooling system. Juan took time to check everything for us and gave us good advice. One of the best we have done in our home since we moved in. THANKS


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you for the 5 stars, Claudia! We are so happy to hear that you had an amazing experience with our HVAC technician, Juan. Thank you for having us out! We are here for your home service needs in the future as well.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great

He was awesome. It already feels better in the house


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you for the 5 stars, Susan! That is wonderful to hear that it already feels better in your home. We are so happy our technician met your expectations.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service

Henry was on time, thorough, and did a great job.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Chris! We are so happy to hear that Henry took great care of you.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

A/C semi annual

As always excellent service, Ronald as polite and professional. Happy to have met him.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

That is wonderful to hear, Terry! Thanks so much for sharing your experience with Ronnie. He really is excellent at what he does and we are glad you feel the same way. Thank you again for the 5 stars!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service and very knowledgeable


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you for the 5 stars, David!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great job!


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thanks for the 5 stars, Claudia!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

good service

good job by shane


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Alexander! So glad Shane took great care of you!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Leaky Pipe Repair

Very thorough and took the time to find what we believe to be the actual problem. Very pleased.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, David! We are so happy to hear that Michael took great care of you. Thank you for giving us the opportunity to serve you!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great Service!! Professional personable Technician.

Great locally owned family business!


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Robert! We are so happy to hear that you love our company. We truly appreciate you taking the time to leave us such a kind review.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Job Locations
for montgomery, tx

Jorden S.

Jorden S. Job Checkin

Sold


Marc H.

Marc H. Job Checkin

Had to reset thermostatic valve to where it would go hot or cold or in between. Set handles wrong yesterday.


Ernest P.

Ernest P. Job Checkin

Diagnostic- no cool upstairs Low charge found leak in evaporator coil. Coil frozen - no static’s Scheduled Jorden to come give pricing.


Marc H.

Marc H. Job Checkin

Came back today to cut out the shark bite fittings and make proper repair. Also climbed on the roof and sealed water heater vent from where we did not seal it up two years ago. Everything is working properly.


Marc H.

Marc H. Job Checkin

Replace cartridge for Breezo sent by Delta. There is still a leak going on called Delta myself they are sending other parts. Did not collect today will collect when we come back, per Bethan.


Ernest P.

Ernest P. Job Checkin

System- master Approx Age of System: 6 Refrigerant Type- / R410a Metering Device- TXV SP/HP: 129/280 SLT/LLT: 47/90 VSAT/LSAT- 44/91 Superheat/Subcool- 3/1 Outdoor Entering Air Temp- 81 Outdoor Fan FLA- 1.2 Compressor RLA/LRA- 6.3/31.7 Contactor Voltage- 240 Capacitor Rating- 40/7.5 Indoor Return Dry Bulb Temp- 68 Return Wet Bulb Temp- 59 Supply Temp- 50 Temperature Difference- 18 Required Difference- 17 Filter Sizes – 20x25x4 Changed Filters – N (Clean) Blew out drain line: N Notes- performed ac tuneup. System was operational upon arrival. No condensation protection. System- Main Approx Age of System: 6 Refrigerant Type- R410a Metering Device- TXV SP/HP: 122/292 SLT/LLT: 51/83 VSAT/LSAT- 41/93


Jorden S.

Jorden S. Job Checkin

Sold


Shane B.

Shane B. Job Checkin

Replaced customer moen positemp cartridge im master shower bottom valve. Tested for operation. Tested water and the softener is working but there is still build up on all faucets from all the chlorine in the water. Recommend replacing the softener with on that will also get the chlorine out of the water. Estimates for gemline will be provided.


Ernest P.

Ernest P. Job Checkin

System- single Approx Age of System: 1 Refrigerant Type- R410a Metering Device- TXV SP/HP: 117/237 SLT/LLT: 52/76 VSAT/LSAT- 39/80 Superheat/Subcool- 13/4 Outdoor Entering Air Temp- 66 Outdoor Fan FLA- 1.2 Compressor RLA/LRA- 9.9/119 Contactor Voltage- 246.0 Capacitor Rating- 70/10 Indoor Return Dry Bulb Temp- 67 Return Wet Bulb Temp- 59 Supply Temp- 51 Temperature Difference- 16 Required Difference- Filter Sizes – (Did not go inside) Changed Filters – N Blew out drain line: N Notes- performed ac tuneup. System was operational upon arrival. Found compressor over amping on startup. Found gas flex line installed incorrectly. Found no condensation protection on the system. Found organic growth on the supply plenum. Recommendations attached. Scheduled next tune up date: 10/28 8-10


Ernest P.

Ernest P. Job Checkin

System- single Approx Age of System: 4 Refrigerant Type- R410a Metering Device- TXV SP/HP: 118/243 SLT/LLT: 48/79 VSAT/LSAT- 38/81 Superheat/Sub-cool - 10/2 Outdoor Entering Air Temp- 73 Outdoor Fan FLA- 2.3 (after repair 1.4) Compressor RLA/LRA- 14.3/127.2 (rated limit-17.9/112) (After repair 9.0/67.3) Contactor Voltage-244.8 Capacitor Rating- 19/2 (45/5) Indoor Return Dry Bulb Temp- 70 Return Wet Bulb Temp- 61 Supply Temp- 52 Temperature Difference-18 Required Difference- Blower FLA- 3.0 Filter Sizes – Changed Filters – N Blew out drain line: N Notes- found unit incorrectly wired at the capacitor - fan common tied into the Herm terminal. This caused over amping on the unit fan and compressor. This coupled with the failing capacitor significantly increased noise levels. Replaced ru


Ernest P.

Ernest P. Job Checkin

System- single (2z) Approx Age of System: 5 Refrigerant Type- R410a Metering Device- TXV SP/HP: 116/283 SLT/LLT: 54/78 VSAT/LSAT- 38/91 Superheat/Subcool- 15/13 Outdoor Entering Air Temp- 75 Outdoor Fan FLA- 1.1 Compressor RLA/LRA- 7.6/113.7 Contactor Voltage- 241 Capacitor Rating- 44.4/6.5 (45/7.5) Indoor Return Dry Bulb Temp- 70 Return Wet Bulb Temp- 59 Supply Temp- 48 Temperature Difference- 22 Required Difference- Blower FLA- 3.2 Filter Sizes – 20x25x4 Changed Filters – Y (provided) Blew out drain line: N Notes- performed ac tuneup. System was operational upon arrival. Found compressor over amping on startup. - this should be addressed to avoid long term damage to the compressor. No blowout valve or primary condensation shutoff. Recommended items attached. Scheduled next tune up date: 11/02 10-2


Marc H.

Marc H. Job Checkin

Performed whole home inspection. Really found no issues at this time except for where they tied the water softener in to the Zurn pex with SharkBites. Gave estimate to fix them homeowner approved we are doing it on April 3. Also homeowner approved to flush water heater that is two years old that we installed. Also noticed the vent for the water heater was not sealed properly as per our company when we did not sell it when we changed water heater. Need to seal tomorrow when I come back for other repairs.


Juan  M.

Juan M. Job Checkin

System- zones Approx Age of System: Refrigerant Type- R410a Metering Device- TXV SP/HP: 106/255 SLT/LLT: 56/78 VSAT/LSAT- 35/85 Superheat/Subcool- 20/7 Outdoor Entering Air Temp- Outdoor Fan FLA- 1 Compressor RLA/LRA-11.5/55.9 Contactor Voltage- 238/26 Capacitor Rating- 70/7.5 actual 69.8/7.5 Indoor Return Dry Bulb Temp- 76 Return Wet Bulb Temp- 68 Supply Temp- 58 Temperature Difference- 18 Required Difference- 15-20 Blower FLA- 5.8 Filter Sizes –2 12x12x1 16x25x1 14x20x1 Changed Filters – N customer will Blew out drain line: N Notes- System- upstairs Approx Age of System: Refrigerant Type-/ R410a Metering Device- / TXV SP/HP: 112/263 SLT/LLT: 49/80 VSAT/LSAT- 37/86 Superheat/Subcool- 13/7


Juan  M.

Juan M. Job Checkin

System- trane Approx Age of System: 4 Refrigerant Type-R410a Metering Device- TXV SP/HP: 102/223/ SLT/LLT: 57/72 VSAT/LSAT- 36/76 Superheat/Subcool- 24/6 Outdoor Entering Air Temp- 64 Outdoor Fan FLA- .9 Compressor RLA/LRA- 4.9/58.8 Contactor Voltage- 238/25 Capacitor Rating- 45/7.5 actual 44.6/7.5 Indoor Return Dry Bulb Temp- 69 Supply Temp- 51 Temperature Difference- 18 Required Difference- 15-20 Blower FLA- 5.7 Filter Sizes – 20x25x4 Changed Filters – Y customer supplied Blew out drain line: Y Notes- performed ac tune up on system and unit is operating within manufactured specs. Did find that unit only has pan switch on but no blow out valve to clear line set and also no in line switch to prevent water from hitting pan. Also customer has a dehumidifier that also is tied to the primary line and no way to clear that or close it when clearing primary line. Suggest blow out valve on both units to keep them clear and a inline on unit to prevent water hitt


Luis M.

Luis M. Job Checkin

As Per Agreement