Great Service by Shane!

Shane was very professional and went over and beyond with his service.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service thanks

Awesome thanks

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Reliable service, polite and supportive stuff

  • Overall Experience
  • Quality
  • Value
  • Professionalism

He was awesome

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Excellent

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great

Work completed, thank you.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great

I was very pleased he was friendly and polite did his work well

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service, very informative

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Job Locations
for montgomery, tx

Juan  M.

Juan M. Job Checkin

AC Diagnostic System: back room. Refrigerant Type R22/ Metering Device-Fixed Orifice SP/HP 43/98 SLT/LLT 75/81 VSAT/LSAT18/81 SH/SC53/0 Outdoor Entering Air Temperature 81 Filter Size(s)12x24x1 Returned tstat to original settings: N left it on fan Unit operational; prior to leaving: N return visit scheduled Notes: Customer stated that unit was not cooling but it was blowing air. Saw on Notes for previous tuneup the unit was low on refrigeration and customer did not want to do anything. Hooked up gauges and found refrigeration very low but before adding more refrigeration want to go inspect coil and saw coil frozen over the customer know we would have to come back tonight to add refrigeration so coil can unfreeze. Booked call for 6-10 Customer just wants to add refrigeration at this time Estimate on invoice is just a worst-case scenario refrigeration unit holds 3 1/2 ponds Recommendations:


Jim V.

Jim V. Job Checkin

Arrived to the Powels residence in complete the estimate for the inside entry light. At this time there is no need for a follow up call.


Michael C.

Michael C. Job Checkin

Came out today to change parts on the burner assembly but rheem sent a box of stuff without the pilot assembly. We are getting them to send the correct parts back out and will be back when they get here.


Shane B.

Shane B. Job Checkin

Arrived to check stopped up master lav drain next to toilet. Removed ptrap and clog was in ptrap and drain arm coming out of the wall. Clean out trap and drain arm. Sink is now draining properly. Flushed with lots of hot water. No answer on second call to Donald


Ernest P.

Ernest P. Job Checkin

Diagnostic- right side (mother in-law suite) 142/348 49/106 63/92 14/14 45/5 run cap blown. Replaced with Turbo200 Added 1 lb of r410a Replaced 45/5 run cap on left side unit and installed a hardstart kit.


Shane B.

Shane B. Job Checkin

Install customers master and guest bath lavatory faucets. Used new supply lines left from the repipe. Reconnect lav drains to new popup assemblies. Loosen packing nuts on 3 outdoor hosebibs put in during repipe.


Caleb C.

Caleb C. Job Checkin

Kitchen sink was backing up slowly. Had a partial blockage showed home owner the cost of running machine and they accepted . Ran machine down the line all 75 ft. Pulled cable back and filled sink multiple times to check for issues. Found none and sink was draining good


Ernest P.

Ernest P. Job Checkin

Follow up diagnostic from last night. 135/364 psi 46/109 sat 49/99 lt 3/10 shsc Cleared drain line. Clog moved to the master bath sink. Need plumber to clear drain. Plumber scheduled this afternoon.


Michael C.

Michael C. Job Checkin

Came out to investigate a water leak that appears to be on the water main. After pumping out the water from the meter box we watched the digital read from both the neighbors meter and our customers and we saw no movement and noticed water seeping from the city side and would recommend the city looking at their end to see if the yolk is leaking possibly. Without movement it doesn’t seem logical to dig the customers line up. They will keep us posted on the situation. Customer paid with the card on file no follow up at this time.


Michael C.

Michael C. Job Checkin

Came out today to conduct annual plumbing inspection included with the plumbing membership. The plumbing really looks great, all toilets in good operation, all drains nice and smooth, no questionable leaks seen, and no visible corrosion. No suggestion to be made today it was a good check up.


Ernest P.

Ernest P. Job Checkin

Drain line blocked on the small unit, left side of the house. Leaking into the emergency pan and draining into the side yard. Was unable to reach Mr. McCracken to get permission to address the issue - the original objective was to just shut the unit off. That is what I did. Breaker on air handler in the off position.


Juan  M.

Juan M. Job Checkin

AC Diagnostic System: upstairs Notes: Customer wanted us to come out and give a quote on a new coil. Unfortunately Lennox offices are closed already so would have to have the office check tomorrow to see if it’s under warranty if it is we can give them pricing on a warranty coil +5 pounds of refrigerant if all 5 pounds of refrigerant are not used we can always takeoff what we didn’t use on the price. If it is not we will recommend a comfort adviser for the unit. Customer had other guy add refrigerant and die test that he found it leaks all over the coil that’s why he knows there is a leak in the coil he will be comparing our prices and his prices to see which one he goes with whenever we send them a price. Recommendations:


Jacob C.

Jacob C. Job Checkin

System-main Approx Age of System: 10 years Refrigerant Type- R410a Metering Device- TXV SP/HP:134/348 SLT/LLT: 63/98 VSAT/LSAT- 46/105 Superheat/Subcool-17/7 Outdoor Entering Air Temp-93 Outdoor Fan FLA- 1.8 Compressor RLA/LRA-11/119 Contactor Voltage-241/24 Capacitor Rating-41 of 45 Indoor Return Dry Bulb Temp-77 Return Wet Bulb Temp-65 Supply Temp- 58 Temperature Difference-19 Required Difference-16-24 Blower FLA- 2.1 Filter Sizes – 20x30x1 Changed Filters – N Clean Blew out drain line: N no valve Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes-system is running within manufactured specs , no issues at this time. Will recommend a blowout valve though to allow drain line to be cleared if blockage occurs. Scheduled next tune up date: Thursday January 7th 12-4


Jim V.

Jim V. Job Checkin

Arrived to the Vasilyeza residence to look at the wiring located by the inside ac unit. While I was there I put a cover over the open hole and put a sleeve over the wire. I also cut back the damaged wire and installed new wire under the breaker. At this time I do not see a reason to do a follow up call.


Jacob C.

Jacob C. Job Checkin

System-main Approx Age of System: 13 years Refrigerant Type- R22 Metering Device- Fixed Orifice SP/HP:76/230 SLT/LLT:54/97 VSAT/LSAT- 45/110 Superheat/Subcool-9/14 Outdoor Entering Air Temp-93 Outdoor Fan FLA- 1.0 Compressor RLA/LRA-7.5/133 Contactor Voltage-242/25 Capacitor Rating-50/4.1 of 55/5 Indoor Return Dry Bulb Temp-76 Return Wet Bulb Temp-63 Supply Temp- 57 Temperature Difference-19 Required Difference-16-24 Blower FLA- 7.0 Filter Sizes – 20x30x1 20x20x1 Changed Filters – N clean Blew out drain line: N no valve Returned tstat to original settings: Y Unit operational; prior to leaving: Y Notes- System is 12 years old and running efficiently. Did find organic growth buildup around blower motor and supply plenum, recommend an air scrubber to kill off organic growth, help prevent further buildup and increase air quality. Recommend a blowout valve to allow drain line to be cleared if blockage occurs. Customer was interested in looking into replacemen