30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Local Reviews
for porter, tx

Rated 5.0 out of 5 stars based on 8 customer reviews

AC Check


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you for the 5 stars, Kelly!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service!

Jeremy gave prompt service, explained what he was going to do and then proceeded. When he finished he explained what he did and the problems he found. We appreciate his time and care. Thanks, Bradbury!


Response from Bradbury Brothers Cooling, Plumbing & Electrical:

Thank you, Austin! We are so happy to hear that Jeremy took great care of you and your home. Thank you so much for giving us the opportunity to serve you!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

On time on the mark

Good job

  • Overall Experience
  • Quality
  • Value
  • Professionalism

5 Stars+

Bradbury Brothers always are prompt ....if late they tell you..courteous and efficient. Pleasure to deal with. Larry my tech was a fine example of such and deserves a big ole shout of "Good Job"...Kudos all around!!!!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great as usual

Always good having BB come, as you can trust the service.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service as always!

Michael was excellent!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Tune up

Great job, will use again, and have already recommended to others. Came well recommended to me by a co-worker.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for porter, tx

Shane B.

Shane B. Job Checkin

remove upstairs American standard toilet tank and replaced the flush valve and tank bolts. Toilet is no longer leaking and is flushing properly


James W.

James W. Job Checkin

Customer had us out today for a toilet in the upstairs guest bath not flushing properly. Found the toilet to be running and had to hold the handle down to get the toilet to flush properly. This indicates that the flapper is failing and will need to be replaced. Toilet is an American Standard 1.28 gpf model. Took a picture of the parts list so that we can order the appropriate parts to make the repair.


Ronald  E.

Ronald E. Job Checkin

System- main Approx Age of System: 8 Refrigerant Type- R410a Metering Device- TXV SP/HP: 115/335 SLT/LLT: 52/90 VSAT/LSAT- 38/104 Superheat/Subcool- 14/10 Outdoor Entering Air Temp- 82 Outdoor Fan FLA- 1.10 Compressor RLA/LRA- 12.53 Contactor Voltage- 240/25 Capacitor Rating- 70/7.5 Indoor Return Dry Bulb Temp- 75 Return Wet Bulb Temp- 65 Supply Temp- 57 Temperature Difference- 17 Required Difference- 15-20 Blower FLA- 7.63 Filter Sizes – 20x25x4 Changed Filters – Y customer provided Blew out drain line: N Notes- Performed ac tune up x1, checked indoor unit for proper operations took amp draws and checked amp draws, coils are clean. Unit has no overflow protection which may cause ceiling damage in the future if drain lines back up. Will recommend complete overflow protection pack. Checked outdoor unit for proper electrical


Jeremy D.

Jeremy D. Job Checkin

Hot water heater leaking. Diagnose and find rust and corrosion on water heater. Hot water heater should be replaced. 9 year old Bradford White water heater. Recommend replacement Rheem tank water heater, or Navien tankless water heater. Average water heater life span is 8-12 years old. Install new Navien tankless water heater with new pan and test for functionality. Recommend water leak protection device (FloodStop) to prevent future damage from water leaks.


Mario S.

Mario S. Job Checkin

System-main Approx Age of System: 10 Refrigerant Type- R410a Metering Device- TXV SP/HP:155/223 SLT/LLT:54/72 VSAT/LSAT-43/80 Superheat/Subcool-11/8 Outdoor Entering Air Temp-62 Outdoor Fan FLA- 1.7 Compressor RLA/LRA-8.3/52 Contactor Voltage-220/28 Capacitor Rating-45 reading-44.6 Indoor Return Dry Bulb Temp-74 Supply Temp-52 Temperature Difference-22 Required Difference-16-22 Blower FLA- 6.9 Filter Sizes – 20x25x4 Changed Filters –N (clean) Blew out drain line: Y Notes-system is working fine , did recommend air scrubber to eliminate air contaminants . Customer does want to see how this pandemic turns out in order to make any future decisions. Scheduled next tune up date: October 20th 9-11


Mario S.

Mario S. Job Checkin

Diagnostic r22 Unit is low on refrigerant and has been filled multiple times in the past. R22 is no longer manufactured and recommend replacement. System is so low at this time that evap coil is freezing over. Scheduled comfort advisor for today at 3:30pm. Unable to take static’s due to coil freezing. Left condenser without power and inside blower remain functional.


Larry W.

Larry W. Job Checkin

Performing semiannual air conditioning maintenance tune-up on Carrier AC system in a residential home. Programming thermostat, checking air filters, testing safety controls/detectors, balancing airflow, assessing ductwork, taking vital readings, and evaluating HVAC system performance. Recommending overflow protection package. System is cooling and ready for Summer weather.


Terence A.

Terence A. Job Checkin

Performing semiannual air conditioning maintenance tune-up on Carrier AC system in a residential home. Programming thermostat, checking air filters, testing safety controls/detectors, balancing airflow, assessing ductwork, taking vital readings, and evaluating HVAC system performance. Recommending blowout valve, UV air purifier, and UV coil cleaning. System is cooling and ready for Summer weather.


Terence A.

Terence A. Job Checkin

Performing semiannual air conditioning maintenance tune-up on Carrier AC system in a residential home. Programming thermostat, checking air filters, testing safety controls/detectors, balancing airflow, assessing ductwork, taking vital readings, and evaluating HVAC system performance. Recommending blowout valve, UV air purifier, and UV coil cleaning. System is cooling and ready for Summer weather.


Terence A.

Terence A. Job Checkin

Performing semiannual air conditioning maintenance tune-up on Carrier AC system in a residential home. Programming thermostat, checking air filters, testing safety controls/detectors, balancing airflow, assessing ductwork, taking vital readings, and evaluating HVAC system performance. Recommending blowout valve, UV air purifier, and UV coil cleaning. System is cooling and ready for Summer weather.


Terence A.

Terence A. Job Checkin

Performing semiannual air conditioning maintenance tune-up on Carrier AC system in a residential home. Programming thermostat, checking air filters, testing safety controls/detectors, balancing airflow, assessing ductwork, taking vital readings, and evaluating HVAC system performance. Recommending blowout valve, UV air purifier, and UV coil cleaning. System is cooling and ready for Summer weather.


Larry W.

Larry W. Job Checkin

Ac tune up on Carrier system.


Adam S.

Adam S. Job Checkin

Estimate to replace faucets.


Larry W.

Larry W. Job Checkin

Trane furnace tune up.


Larry W.

Larry W. Job Checkin

Carrier furnace tune up.