Super AC Check up

On time, thorough and done in a timely manner. Considerate to others who are working from home.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Owner

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Excellent Service and Customer Care

As always, Bradbury Brothers provided excellent service, explanation of procedures, and customer care through Fernando, today’s technician. They were extremely careful in safety precautions for us and their technician due to the COVID-19 virus. They went above and beyond in replacing a part that was still working, but with diminished capacity. We would normally have to wait for that part to fail completely, and consequently shut down the whole unit, for the warranty to replace that part. We are retired and Fernando did not want us to suffer in case that part failed during our hot summer. He spoke with the “brothers” and they decided to replace this part with NO CHARGE to us! Family caring and service is what makes this company exceptional. Please call Bradbury Brothers for all you HVAC needs!


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Linda! We are so happy to hear Fernando took great care of you. #1 in our values statement is taking great care of our customers, so it is wonderful to hear that Fernando took this to heart. We want you and your home to be prepared for a very HOT summer! Thank you so much for taking the time to write us such a nice review, and for giving us the opportunity to serve you.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service

Quick, yet thorough, quality work


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you for the review, Laura! So happy to hear this about your visit with Nic!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

He's great


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you for the 5 stars, Jill!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Excellent


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you so much, John!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great Service

Technician was very knowledgeable, explained everything in detail. He was very polite.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Kathy! We aim for 100% satisfaction with our people, and are always so excited when we hear that our team members were knowledgeable and polite. Thank you for taking the time to write us.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great guys


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Jill!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Job Locations
for shenandoah, tx

Michael C.

Michael C. Job Checkin

Came out today to change the defective part on the tankless on the left out of the two. Turn the unit back on tested the unit and no code was thrown while I was there, that should resolve the issue. No follow-up needed at this time.


Michael C.

Michael C. Job Checkin

Came out today to take a look at another leaking lavatory in the home. After taking pictures and sending them to Shawna she will handle contacting the manufacturer like we did last time for the other Fossett and getting this one replaced as well. We will get back with a customer when we find out when we should be expecting the Faucet


Juan P.

Juan P. Job Checkin

BB Corrections


Henry M.

Henry M. Job Checkin

System- Bryant Approx Age of System:2 Refrigerant Type- R410a Metering Device- TXV SP/HP:126.6/272.9 SLT/LLT:52.3/80.5 VSAT/LSAT- 43.6/89.3 Superheat/Subcool-8.5/8.8 Outdoor Entering Air Temp-72 Outdoor Fan FLA- .9 Compressor RLA/LRA-10.5/ Contactor Voltage-243.4/25.1 Capacitor Rating-44.1/7.2 Indoor Return Dry Bulb Temp-71.4 Return Wet Bulb Temp-64.6 Supply Temp- 52.8 Temperature Difference-18 Required Difference-16-20 Blower FLA- 5.5 Filter Sizes –20x25x4(2)(still clean at this time) Changed Filters – N Blew out drain line: Y Notes-Upon arrival, checked in with Mrs.Kress and located hvac equipment. ,add the call for cooling and system came on accordingly. At the condenser, refrigerant pressures and electrical readings are within manufacture specifications. After taking readings


Michael C.

Michael C. Job Checkin

Got on the phone with rinnai, the case number is 378383. They are sending a new flame rod assembly to Bradbury brothers to resolve the code 11 issue on the master unit tankless. And the master lav sink on the left side we ran a hand rod to unstop and poured customers draini down to help clean it out. Sink drains good and the part should be in a few days and we will set up app. To service the tankless.


Jeremy D.

Jeremy D. Job Checkin

System- Approx Age of System: 9yrs Refrigerant Type- R410a Metering Device- TXV SP/HP: 109/29 SLT/LLT: 64/63 VSAT/LSAT- 35/75 Superheat/Subcool- 28/12 Outdoor Entering Air Temp- Outdoor Fan FLA- .7 Compressor RLA/LRA- 6.7/88 Contactor Voltage- Capacitor Rating- 40.77/3.39 Indoor Return Dry Bulb Temp- 68 Return Wet Bulb Temp- 61 Supply Temp- 49 Temperature Difference- 19 Required Difference- 16-20 Blower FLA- 4.9 Filter Sizes – 20x30 Changed Filters – Acceptable Blew out drain line: Y Notes- Unit was operational on arrival. Checked filters. Checked operating pressures and temperatures. Checked indoor and outdoor electrical. Superheat is high and subcooling is high. Condenser coil is clogged with debris. Water washed condenser coil. Superheat is still high. Through chemical should be done be any


Fernando G.

Fernando G. Job Checkin

System- D/s system Approx Age of System: 11 Refrigerant Type- R410a Metering Device- TXV SP/HP: 111.7/301.3 SLT/LLT: 50.1/86 VSAT/LSAT- 36.9/95.9 Superheat/Subcool- 13/10 Outdoor Entering Air Temp- 78.3 Outdoor Fan FLA- 1.4 Compressor RLA/LRA- 11.2/138.7 Contactor Voltage- 247.3 Capacitor Rating- 68/6 Indoor Return Dry Bulb Temp- 68.8 Return Wet Bulb Temp- 43.4 Supply Temp- 49.9 Temperature Difference- 18.9 Required Difference- 16-20 Blower FLA- 8.1 Filter Sizes – 20x25x1/12x24x1 Changed Filters – N Blew out drain line: N Notes- system has heavy organic growth in the supply plenum at this time it doesn’t look like its reached the duct work but left untreated it will continue to grow and spread throughout the duct system. These organic growths not only affect the workings of the equipment but have a health affect on people with allergies and respiratory issues. Filters have been replaced recently no need to change them at this time, there is no service


Fernando G.

Fernando G. Job Checkin

System- single system Approx Age of System: 5 Refrigerant Type- R410a Metering Device- TXV SP/HP: 114.9/223.5 SLT/LLT: 60.8/74.9 VSAT/LSAT- 38.5/76.4 Superheat/Subcool- 22.4/1.4 Outdoor Entering Air Temp- 69.1 Outdoor Fan FLA- .6 Compressor RLA/LRA- 6.5/ n/a system has a circuit board Contactor Voltage- n/a no contactor Capacitor Rating- 34/2 Indoor Return Dry Bulb Temp- 65.9 Return Wet Bulb Temp- 41.8 Supply Temp- 44.3 Temperature Difference- 21.6 Required Difference- 16-20 Blower FLA- 3.2 Filter Sizes – 20x25x4 Changed Filters – Y Blew out drain line: Y Notes- the condenser capacitor value tested and rated by the manufacturer is 40/5mfd +-5% at this time the capacitor is out of tolerance reading 34/2, since our last visit the value read 37.4/3.1mfd the capacitor value has dropped significantly. I recommen


Mario S.

Mario S. Job Checkin

System-downstairs Approx Age of System:3 Refrigerant Type- R410a Metering Device- TXV SP/HP:155/229 SLT/LLT:60/81 VSAT/LSAT- 42/88 Superheat/Subcool-18/7 Outdoor Entering Air Temp-73 Outdoor Fan FLA- 1.1 Compressor RLA/LRA-11.6/132.8 Contactor Voltage-28/234 Capacitor Rating-66 of 70 Indoor Return Dry Bulb Temp-75 Supply Temp-56 Temperature Difference-19 Required Difference-16-22 Blower FLA- 8.1 Filter Sizes –20x25x1 Changed Filters –N (clean) Blew out drain line: N (no blow out valve) System-MB Approx Age of System:4 Refrigerant Type- R410a Metering Device- TXV SP/HP:127/218 SLT/LLT:57/80 VSAT/LSAT-45/89 Superheat/Subcool-12/9 Outdoor Entering Air Temp-73 Outdoor Fan FLA- .8 Compress


Luis M.

Luis M. Job Checkin

As Per Agreement


Ken P.

Ken P. Job Checkin

Diagnostic System: AC 19/ services units 2093-2110 Refrigerant Type R22 Metering Device- TXV SP/HP 66/177 SLT/LLT 53/80 VSAT/LSAT 38/93 SH/SC 14/12 Outdoor Entering Air Temperature 77 Notes: Talked to Brandon over the phone. Explained to him that the system has a refrigerant leak and that due to its age of 15 years and using the phased out R22 refrigerant I highly recommend replacing the system. He said that due to the current situation with the Coronavirus, he would like it have the system topped off with refrigerant to hold over until the coronavirus issue passes, although he would also like to get an estimate to replace, because they plan on doing so as soon as they’re able.


Jim V.

Jim V. Job Checkin

Check light bulbs in all 4 buildings ( took pictures of lights that need attention ) working on a price


Jorden S.

Jorden S. Job Checkin

Sold


Ken P.

Ken P. Job Checkin

Hot water heater not making hot water. Diagnose and find rust and corrosion on water heater. Hot water heater should be replaced. 20 year old Navien water heater. Recommend replacement Rheem tank water heater, or Navien tankless water heater. Average water heater life span is 8-12 years old. Install new Navien tankless water heater with new pan and test for functionality. Recommend Gemline water softener to protect new water heater from hard water damage.


Mario S.

Mario S. Job Checkin

Air conditioner not blowing air. Air conditioning repair and maintenance tune up. Diagnose and perform annual AC maintenance service plan on Rheem cooling system. Replace capacitor and check evaporator coils on 15 year old HVAC system. AC maintenance complete which will help lower cooling cost for this residential customer. R22 refrigerant is no longer available in the United States. Recommend replacement with new Comfortmaker air conditioning system. Air conditioner is now ready for spring weather.