30045 FM 2978 Rd.
Magnolia, TX 77354
2816515484

Our Top Cities


Local Reviews
for the woodlands, tx

Rated 4.9 out of 5 stars based on 146 customer reviews

Awesome Service

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Impressed

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Knowledgeable, great service

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service

I enjoyed meeting Mark and he explained my Water Heater repair options. He is knowledgable and will request him next time I need service.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Richard! We are so happy to hear Marc took great care of you. We will add a note to your account that he is your preferred plumber. Thank you for giving us the opportunity to serve you!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Excellent service! Polite and friendly and efficient.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thanks for the 5 stars, Gillian! We are so happy to hear we provided you with excellent, polite, friendly and efficient service.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

review

good


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you for the 5 stars, Kai!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service. Caleb was very knowledgeable and professional

I will recommend Bradbury Brothers.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Gary! We truly appreciate your recommendation of our company. Thank you for giving us the opportunity to serve you!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Friendly, efficient!

Henry quickly diagnosed the problem, respires the unit, and was very friendly!


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Neal! We are so happy to hear Henry took great care of you. Thank you for giving us the opportunity to serve you.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service, very professional


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, Matt!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Michael was the greatest and all over it

Beat pcompany for all needs and I have managed some so I know what I’m talking about.


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you, David! Your kind words mean the world to us - we put a lot of time and hard work into being the best in the business. Thank you for taking the time to write us such a nice review!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Job Locations
for the woodlands, tx

Michael C.

Michael C. Job Checkin

Came out today to conduct a home inspection plumbing annual everything else in the house seems to check out fine except for the water heater there was a little water in the pan so I mentioned to the homeowner that they should probably change it at this time. Gave them estimates for a ten-year 40 gallon tall and a six-year 40 gallon tall gas water heater because they didn’t really want to do tankless and it was an optimal for theirs situation. They went with the 10 year 40 gallon tall gas water heater we changed it outToday water heaters back in filled up lit and tested no follow-up needed at this time. Did note that the drain on the kitchen had too big of a P-trap on it and should be corrected but told the customer if they have any problems with it we can address it then.


Jennifer  R.

Jennifer R. Job Checkin

HVAC Comfort Club Membership 2 system Prepaid


Ken P.

Ken P. Job Checkin

AC Diagnostic System: Main Refrigerant Type R410A Metering Device- TXV SP/HP 67/258 SLT/LLT 83/85 VSAT/LSAT 13/85 SH/SC 69/0.2 Outdoor Entering Air Temperature 83 Notes: Condenser showing low pressure lock out. Reset and found low refrigerant pressures. Checked system with electronic. Leak detector and found major refrigerant leak in the evaporator and a smaller leak at the bottom of the condenser coil. Warranty expires in July 27, 2019. Mr Brehaut would like to relieve a replacement estimate.


Mario S.

Mario S. Job Checkin

System analysis x1 Was unable to find any burnt wires or even scent of a burning wire but I did see unit has a fresh air damper which brings in air from outside and they are doing major construction about 40 yards from the home that may be causing the smell. The unit did have a 120v uv light on main plenum and sub plenum that weren’t functional. Closed fresh air damper and Paul will monitor the smell also Recommended air scrubber to eliminate organic growth forming inside the supply plenum and to eliminate air contaminants in the home. sealed the hole in the sub plenum where the other uv light was And added the air scrubber into the main plenum. Tested the unit and system is fully functional. No other issues are visible at this time .


Mario S.

Mario S. Job Checkin

System-upstairs Approx Age of System:3 Refrigerant Type- R410a Metering Device- TXV SP/HP:144/246 SLT/LLT:55/84 VSAT/LSAT- 44/92 Superheat/Subcool-11/8 Outdoor Entering Air Temp-79 Outdoor Fan FLA- .8 Compressor RLA/LRA-10.4/49 Contactor Voltage-228/27 Indoor Return Dry Bulb Temp-73 Supply Temp- 54 Temperature Difference-19 Required Difference-16–22 Blower FLA- 3.6 ____________________________________________ System-downstairs Approx Age of System: 3 Refrigerant Type- R410a Metering Device- TXV SP/HP:144/280 SLT/LLT:57/81 VSAT/LSAT- 47/87 Superheat/Subcool-10/7 Outdoor Entering Air Temp-79 Outdoor Fan FLA- 1.1 Compressor RLA/LRA-12.5/70 Contact


Henry M.

Henry M. Job Checkin

System-downstairs rheem Approx Age of System:3 Refrigerant Type- R410a Metering Device- TXV SP/HP:132.9/277.4 SLT/LLT:58.4/76.5 VSAT/LSAT-45.9/90.6 Superheat/Subcool-12.5/14 Outdoor Entering Air Temp-71 Outdoor Fan FLA-.6 Compressor RLA/LRA-8.4 Contactor Voltage-237.7/24.5 Capacitor Rating-46.4 Indoor Return Dry Bulb Temp-71.7 Return wet bulb: 61.9 Supply Temp-53,1 Temperature Difference-18 Required Difference-16-20 Blower FLA-6.5 Filter Sizes –20x25x4 Changed Filters – Y Blew out drain line: Y Notes- System-upstairs Amana Approx Age of System:5 Refrigerant Type- R410a Metering Device- TXV SP/HP:125.8/260.7 SLT/LLT:50.8/80.0 VSAT/LSAT-53.5/85.9 Superheat/Subcool-8.6/5.2 Outdoor Entering Air Temp-71 Outdoor Fan FLA-.8 Compressor RLA/LRA-7.5/ Contactor Voltage-237.8/24.5 Capacitor Rating-35.1/2.9(rated 45/5) Indoor Return Dry Bulb Temp-69.2 Return wet bulb; 60.4 Supply Temp-52.4 Temperature Difference-17 Required Difference-16-20 Blower FLA-5.2 Filter Sizes –


Jeremy D.

Jeremy D. Job Checkin

System- Approx Age of System: 1yrs Refrigerant Type- R410a Metering Device- TXV SP/HP: 132/270 SLT/LLT: 59/80 VSAT/LSAT- 45/88 Superheat/Subcool- 13/8 Outdoor Entering Air Temp-75 Outdoor Fan FLA- 1.0 Compressor RLA/LRA-10.6/122 Contactor Voltage-244/26 Capacitor Rating- 43.67/4.89 Indoor Return Dry Bulb Temp-73 Return Wet Bulb Temp-65 Supply Temp- 53 Temperature Difference- 29 Required Difference- 16-29 Blower FLA-4.6 Filter Sizes – 20x25x4 Changed Filters – Y (customer supplied) Blew out drain line: N (No blowout valve) Notes- Unit was operational on arrival. Checked filters. Checked operating pressures and temperatures. Checked indoor and outdoor electrical. Condenser LRA is over rating of 109a. All other components showed no visible issues at this time. Recommend compressor saver-(to re


Caleb C.

Caleb C. Job Checkin

Did whole house inspection and found stem for faucet upstairs hard to turn in bathroom . Home owner will be getting new stem for us to come and install. Laundry room washer box and valves were not in the best shape and valves were corroded . Gave estimate for replacing washer box and valve for unit and for the faucet repair. The rest of the house was in good shape and had no major issues at this time .


Jorden S.

Jorden S. Job Checkin

Special commercial pricing


Ronald  E.

Ronald E. Job Checkin

System- main Approx Age of System: 9 Refrigerant Type-R410a Metering Device- TXV SP/HP: 113/270 SLT/LLT: 61/89 VSAT/LSAT- 37.2/88.6 Superheat/Subcool- 23/3 Outdoor Entering Air Temp- 68 Outdoor Fan FLA- .90 Compressor RLA/LRA- 11.6 Contactor Voltage- 240/25 Capacitor Rating- 70/ run 7.5 Indoor Return Dry Bulb Temp- 71 Return Wet Bulb Temp- Supply Temp- 54 Temperature Difference- 17 Required Difference- 15-20 Blower FLA- 5.8 Filter Sizes – 20x30x1 16x25x1 Changed Filters – Customer will replace Blew out drain line: Y Notes- performed ac tune up x1, checked indoor unit for proper operations, took amp draws, checked electrical connections. Unit has overflow protection. Did find organic growth on the outside of plenum (see pictures) which can cause the spread throughout the inside or ductwork. Outdoor unit


Mario S.

Mario S. Job Checkin

System-upstairs Approx Age of System:1 Refrigerant Type- R410a Metering Device- TXV SP/HP:132/276 SLT/LLT:55/79 VSAT/LSAT- 43/88 Superheat/Subcool-12/9 Outdoor Entering Air Temp-75 Outdoor Fan FLA- .36 Compressor RLA/LRA-10.2/55 Contactor Voltage-228/27 Indoor Return Dry Bulb Temp-73 Supply Temp- 52 Temperature Difference-21 Required Difference-16-22 Blower FLA- 5.6 Filter Sizes –20x25x4 Changed Filters – N (Clean) Blew out drain line: Y Notes-recommended air scrubber to eliminate any air contaminants, recommendations were declined. Spoke to Richard about renewing membership and he would like the office to send him an email with the membership information and he will reply yes or no.


Marc H.

Marc H. Job Checkin

Homeowner had us out today because he had heard rumblings from his water heater due to sediment buildup. Explain to homeowner that flushing it might help it might not help her potential he cause it to leak faster than it normally would because of the age. Gave him as well to flush it and also gave him an estimate to change it. Homeowner decided to just change water heater for now. He did sign up for Comfort club.Also changed out toilet tank lever and hall bathroom by the laundry room


Luis M.

Luis M. Job Checkin

BB Correction


Michael C.

Michael C. Job Checkin

Came back and removed aerator on faucet for customer, problem solved .didn’t go get her to show her the Faucet before because she was in the middle of eating breakfast.


Michael C.

Michael C. Job Checkin

Came out today to change out customers master tub deck mount trim, used deltas warranty faucet that was sent change out went well. No leaks anymore Fossett functions correctly. Also unstop the head on the faucet in the laundry room. No follow-up needed it’s ready for tile to cover up. Customer paid with a visa on file.