521 J PL 625
Plano , TX 75074
469-252-0599

Local Reviews
for rockwall, tx

Rated 4.6 out of 5 stars based on 7 customer reviews

Winter check-up

  • Overall Experience
  • Quality
  • Price
  • Convenience

Heating Maintenance

John was our service tech and he serviced the AC/Heating units. John noticed that we have a lot of air purifiers and he a suggested a UV air filtration system for cleaner air in our home. He was very knowledgeable and helpful. I’m always happy with Chrome Heating,Air and Plumbing service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast service

Staff is great and hard working but one of my bedrooms isn't cooling and main door on unit doesn't snap shut..

  • Overall Experience
  • Quality
  • Price
  • Convenience

As always, great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Timely and efficient install, very profession.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great sales and service

Good price was offered and also received Costco benefits. Installation was professional and smooth. I would recommend Chrome to friends. I had two complete Lenox systems installed replacing original units and both are running great. Thank you Ron (sales) and George and crew ( installers) for all the great work you did.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very Reliable

Ray is a very nice guy,quick and to the point just the way I like it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for rockwall, tx

Jeremy P.

Jeremy P. Job Checkin

Upon arrival re-read the notes from April and found that no repairs have been done yet, checked RTU’s just to confirm repairs, will also need to add a blower wheel replacement to RTU3.


Jeremy P.

Jeremy P. Job Checkin

Commercial service in Rockwall and Upon arrival found three RT use that had the drain line disconnected. Reattach drain lines and make sure drains had a slow falling towards the main drain point, systems are draining properly at this time. Other systems still have issues only three systems are working out of six.


Angela E.

Angela E. Job Checkin

Came out on 2 system maintenance Checked bearings checked blades checked filters checked drain line checked duct work checked insulation checked Amp draws checked contactors checked run capacitors checked electrical connections checked pressures checked temp split across unit checked coils Found 3 pieces of equipment do not have surge protection besides th e downstairs condenser. Outdoor coils are dirty and need to be washed Both filters need be replaced 20x25x5 & 16x25x4 Neither unit has IAQ (INDOOR ARE QUALITY.)


Angela E.

Angela E. Job Checkin

Recover refrigerant Replace txv and filter dryer Flush out lines Pressure test Pull vacuum on system Recharge.


Angela E.

Angela E. Job Checkin

Upon arrival met with ken and began diagnosing system. Found that in heat mode or cool outdoor unit will not turn on. Checked outdoor unit and found that it was locked out on high head pressure, reset outdoor unit and condenser came on. Pressures in heat mode rose up to 600psi before turning off. Switched system to cool mode and pressures were ok. After speaking with ken came to a conclusion that the outdoor txv is restricting the flow of refrigerant causing high pressure lock out. Invoice/labor will be taken care of by Lennox. Part is under warranty through Lennox. Customer wants us to email past service and maintenance invoices along with information on cool care warranty. Lennox in Allen has parts in will call. Michael wants quote approved before any work done.


Angela E.

Angela E. Job Checkin

Checked amp draws on inducer fan motor and blower motor, cleaned flame sensor checked air filter, checked safety devices, checked heat exchanger it was good, check igniter


Angela E.

Angela E. Job Checkin

Recovered refrigerant from system. Removed dryer and txv. Installed new txv and brazed in new dryer. Pressure tested system with nitrogen, disconnected evaporator coil from furnace, hung new straps, moved evaporator coil over 8", built/installed transition between furnace and evaporator coil, taped of duct connections, leveled off unit, mastic sealed evaporator and furnace, pressure tested system with nitrogen, pulled vacuum on system, weighed in 410a refrigerant into system, reset unit, reconnected drain line to evaporator, ran system through cooling cycle and tested system. Unit is operational at this time.


Darius M.

Darius M. Job Checkin

Contaminated refrigerant, bad filter drier. Need to recover refrigerant, purge system, pull vacuum, replace filter drier, recharge. 10 YEAR PARTS AND LABOR ON THIS SYSTEM


Darius M.

Darius M. Job Checkin

Did spring maintenance, found low refrigerant in one unit. Charged by superheat. During fall maintenance if it's low be prepared to do a leak check. Also accidentally stepped through the ceiling. Need to schedule drywall repair.


John W.

John W. Job Checkin

Dispatched to no heat. Upon arrival unit was heating. Caretaker said that the bottom breaker in the air handler was tripping. Upon inspection the lug nuts securing the wires were loose. We tightened the connections and ran through the system to make sure there were no further issues. No other issues were found. Unit is still heating upon departure. Didn't charge service fee.


John W.

John W. Job Checkin

Dispatched to unit not working. Uoon arrival unit was working properly, customer stated that that the thermostat lost power Sunday and returned today (Wednesday) prior to my arrival. She had used the air conditioning Sunday and I believe triggered the float switch. I blew out drain lines and rewired float switch to only cut off heat pump. Unit is working properly upon departure.


John W.

John W. Job Checkin

Dispatched to unit not heating. Fuse was blown. After extensive diagnostic with coleman tech support. We diagnosed a bad defrost board. I installed a new defrost board and rewired the entire system.


John W.

John W. Job Checkin

Completed two system fall matience. Both units are 3 year old lennox units. Both are operating properly and safe to operate at this time. Pictures and report attached.


John W.

John W. Job Checkin

System wasn't running at all upon arrival. After diagnostic inside unit wiring was a mess and low voltage wires were touching and blew the fuse. After replacement of fuse and repairs of wiring unit is running properly.


John W.

John W. Job Checkin

Completed 2 system fall matience on 4 year old lennox units. All heating elements, and safety features are working properly at this time. Left estimate for UV light for whole home air purification.