1570 Old York Road
Abington, PA 19001
215-659-4343

Job Locations
for abington, pa


Map of Abington PA
Paul T.

Paul T.


Job Checkin

Performed preventative maintenance for a Goodman ac system model #Gsc130301ae, serial #0707555256. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. Replaced the air filter size 16x25x1. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The blower motor amp draw is within normal range. The temperature split is at a 19. The condenser coil’s are clean and in good condition. The condenser amp draws are .54 for the fan and 4.8 for the compressor. The refrigerant pressures are within normal range for the temperature outside today. The system is operating properly at this time. Performed preventative maintenance for a Trane furnace model #Tud100c936h3, serial #L4147l52g. Removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Checked all electrical components n