Performed preventative maintenance on a Goodman AC system. Model number: GAW14L24C22SA. Serial number: W1M6119549. Upon arrival the unit was on at the thermostat. I adjusted the temp to have the AC run. Went to the unit in the closet. Turned the unit off at the switch. Removed the panel to the evaporator coil. Inspected the coil for any dust build up. Poured water into the condensate trap and watched it drain properly. Poured water into the condensate pump and watched it pump out properly. Removed the panels to the furnace. Checked the electrical connections to make sure they were properly secure. Checked the blower motor and fan for any dust build up. Changed the 14x25x1 filter supplied by the homeowner. Took an amp draw of the motor. Running within the manufacture’s specs. Placed the panel back on the unit and watched it run. Went outside to the condenser he watched it run. Checked the coils for any dirt build up. Removed the panel and brushed out any spider webs. Checked the contact