1570 Old York Road
Abington, PA 19001
215-659-4343

Local Reviews
for langhorne, pa

Rated 4.8 out of 5 stars based on 6 customer reviews

Excellent Service but higher price!

Best service!


Response from Chud Air Conditioning & Heating:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service

We are fully satisfied with great service from the technician.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience, Hasmukh, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

Paul was excellent ,explained everything and fixed the issue .


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

CHUD - PAUL ASH Review

Excellent


Response from Chud Air Conditioning & Heating:

5 stars, thank you John!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy with service?


Response from Chud Air Conditioning & Heating:

Hi Bob & Peggy what would make you give us that 5th star? Please give us a call to discuss, 215-659-4343.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Tech arrived on time and spent an ample amount of time on yearly maintenance


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Larry & Carol. The Chud team appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for langhorne, pa

Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a 3 year old Goodman heat pump. Model #GSZ140361 , serial #1905386612 . Upon arrival the homeowner had the system set to heat. I turned off the thermostat, powered down the air handler and removed the access panels. The evaporator coil’s are clean and in good condition. I tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. I replaced the 16x20x1 air filter supplied by Chud. Checked all electrical connections to ensure that they are secure and in good condition. The blower motor and wheel are clean as well. I re attached the access panels and powered up the system. I called for ac and observed the system starting normally. The condenser coils are clean and in good condition. The condenser amp draws are .78 for the fan and 7.56 for the compressor. The temperature split is at a 21° differential. The system is operating properly at this time. 2 full system Chud Club Memberships Membership incl


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a 3 year old Goodman heat pump. Model #GSZ140301, serial #1908027860. Upon arrival I turned the thermostat to the off position. I powered down the air handler and removed the access panels. The evaporator coil’s are clean and in good condition. I tested the drain line and drain pan with several bottles of water to ensure that there are no leaks or clogs. I replaced the 16x20x1 air filter Chud supplied. Checked all electrical connections to ensure that they are secure and in good condition. The blower motor and wheel are both clean and in good condition. I re attached the access panels and powered the system back up. I called for AC and observed the system starting normally. The heat pump coils are dirty and could be cleaned. The heat pump amp draws are .80 for the fan and 5.69 for the compressor. The temperature split is at a 19° differential. The system is operating properly at this time. Per the office this is a bill out. The landlord is not ava


Paul A.

Paul A. Job Checkin

I was dealing with contractor. Not the Home owner.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning on a 3 bedroom single system home. Customer opted out of sanitation. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed a first floor dryer vent cleaning. Dryer vent, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Shane A.

Shane A. Job Checkin

Customer’s hot water was not coming on. Notice the pilot was out, I took it out cleaned it off and the water heater started. System is operating properly at this time. M#Q212009860 s#PROG50-38N RH60


Frank B.

Frank B. Job Checkin

Returned to replace lennox gas valve on a spark ignition furnace. Installed a universal gas valve and tested the system. Found no gas leaks from this gas valve and system was operating properly. If other problems happen to occur outside of this issue I recommend replacing the system due to age.


Paul A.

Paul A. Job Checkin

Did they preventative maintenance on a train gas furnace. During the maintenance I noticed the heater was not working. To make the furnace operational we would need to replace gas valve also would need to replace burner rack and would need to replace hot surface igniter and flame sensor after telling the customer this and the pricing of the repair quote and that it’s not guaranteed he is having Steve come out to quote him a new system. M#TUX1B060A9361AB s#63735SM7G


Paul A.

Paul A. Job Checkin

Did a maintenance on a Lenox gas furnace. During the maintenance I clean the flame sensor. Also I cleaned out the burner box and the blower motor housing. Also shop vac the entire unit because it’s in the laundry room and had a lot of dryer lint on it. Also did an amp check on the inducer motor and the blower motor which both meet the furnace specs. Also did a combustion analyzer test the co level was seven and the O2 level was 17. Also changed out to 16 x 25 by one filter. System is running properly at this point. M#G60UH-36B-09010 s#5911A06065.


Frank B.

Frank B. Job Checkin

Came out to inspect the gas furnace. Found the replacement universal Honeywell electronic gas valve we put in is making ticking noises and not working properly we will need to return as soon as possible to replace this valve and test system upon completion. I found no other issues at this time. All other electrical components are operating as they should. Recommend updating system in near future since it’s older but found no safety issues from heat exchanger or any other issue. System is still operational but valve is sticking. Unable to repair today but office will schedule as soon as possible. Attached is estimate for valve replacement. The valve is electronic with pilot tubing for spark ignition. No standing pilot on this system.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 2 bedroom single system house. All vents are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!


Frank B.

Frank B. Job Checkin

Customer called for no air-conditioning. Upon inspection I found that the air handler was operating but the condensing unit was not. Went outside to inspect the outdoor unit and found the contactor pulled in with no operation. Opened up the control compartment and found the capacitor to be swollen and no longer good. Replace the 35+5 dual capacitor and tested the system. System is operating properly after the replaced capacitor. No charge for service or parts per the office due to factory warranty.


Paul T.

Paul T. Job Checkin

Came out today for a no ac call. Upon arrival I was told that the secondary pan had filled up and the office had someone clean out the water and blow compressed air down the clogged drain line. After the drain line was fixed the system just wouldn’t start. Upon inspection I found the thermostat batteries needed to be replaced. I replaced the batteries and called for ac. The system started right up. I checked the drain line by flushing it with multiple bottles of water. I found that the drain line was still clogged. I blew out the line again using the Gallo gun. I tested the line again and it drained properly. I was told that this is the second time the system has clogged. I advised that the drain line should be replaced due to the condition of the drain inside. Nordyne system model #b5bmt48kc, serial #b5d080709286.


Paul T.

Paul T. Job Checkin

Came out today for a leaking Goodman system. Upon inspection I found that the drain pan and drain line were backed up and filled with water. I opened the clean out T and found a piece of insulation in the clean out T. I was able to clear the blockage with a pen. The water immediately went down the drain. I tested the drain with several bottles of water to ensure proper operation. The system is operating properly at this time.


Frank B.

Frank B. Job Checkin

Customer called for air conditioning not working. Replaced pump under warranty since it’s only two days old. Observed the pump moving water to the outside pipe for condensation removal 5 times. System is operating properly at this time.


Matthew M.

Matthew M. Job Checkin

Ran slim duct on lineset. Install is complete