1570 Old York Road
Abington, PA 19001
215-659-4343

Our Top Cities


Local Reviews
for lansdale, pa

Rated 4.8 out of 5 stars based on 5 customer reviews

CHUD

Fantastic & professional, we love this company


Response from Chud Air Conditioning & Heating:

Aww, thanks Kathy! Chud loves our customers too.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exceptional, super friendly

Keith and his assistant were pleasant and efficient! We had our duct work and dryer vent cleaned out.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Rosie, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service. Good price.

Very friendly and courteous.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great service and fairly priced.


Response from Chud Air Conditioning & Heating:

We always strive for 5, please give us a call at 215-659-4343 to let us know what we could have done to get that 5th star.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Top Notch!!

Fantastic!! Complete professionals, super efficient and very friendly crew. We will highly recommend CHUD! We are thankful and grateful!


Response from Chud Air Conditioning & Heating:

Thanks for the awesome review Kathy. We appreciate it!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lansdale, pa

Keith R.

Keith R. Job Checkin

Installed a new backdraft damper into the flex line to prevent the wind from making noise and blowing the lint back into the dryer. Everything is firmly in place and dryer has proper exhaust flow. Thank you for your business!


Paul A.

Paul A. Job Checkin

Do they preventative maintenance on a four zone mini split heat pump. During the maintenance I cleaned all filters in the air handler‘s. Then turned on the heat to make sure they were all working properly. Then went outside borrow the heat pump check temperatures and pressures to make sure all the refrigerant was good which it was. Made sure all drains were unclogged. System is running properly at this time. M#ASU9RLF1 s#MXA 252562 m#ASU7RLF1 s#MWA 179202 m#ASU7RLF1 s#MWA 179677 m#ASU15RLF1 s#JWA 015314 m#AOU36RLXFZ1 s#LXN 058129


Paul A.

Paul A. Job Checkin

Preventative maintenance on a Bryant standard efficiency gas furnace. Combustion analysis performed CO PPM 6. Homeowner replaced his own MERV 11-16x25x4 air filter. System was short cycling and addressed the issue by decreasing the gas pressure. The current temperature rise 33 degrees, manufacturer specs call for 30-60. There is a bypass humidifier mounted on supply plenum and connected to return drop. Completed the service on humidifier (#35 water panel Chud supplied). Humidifier was wired incorrectly. Corrected issue and tested for proper operation. System is now operating properly and not short cycling. Today’s charges are for the humidifier service and to rewire humidifier. Bryant gas furnace M#800SA60110E21A-A, S#4320A31164. Filter size-MERV 11-16x25x4 (3M Brand). #35 water panel in fall. ***PM HT was paid on 08/22/22 and collected by JD.*** Discussed adding a 2nd system. There is attic space available. This would involve adding all new ductwork, registers and also discussing


Paul A.

Paul A. Job Checkin

Quote to be provided to replace existing Carrier 3 phase, 208/230 volt gas package unit. Customer believes it is 15 ton, however we will research the model and serial number. The existing unit is already sitting on a curb adapter. The actual roof opening is 116” by 85” and the existing unit sits on an adapter that is 17” high off of the roof opening. The forks on the Carrier are 86” wide and 91-1/4” long. The existing unit is screwed down to the adapter and the gas shutoff is covered in roof muck/sealant. It’s likely that we’ll need a custom adapter made with the same measurements that will transition to fit a replacement unit. Pictures in ST. Has economizer. The existing unit condenser coil fins are all smashed in. Customer reported that kids sometimes do get on top of the roof here and may have vandalized the equipment. The existing Carrier model number is M#48HJF017 - - - 5A1AA and the serial number is 0504F14359. Crane height 40 feet with about a 40 foot reach in.


Paul A.

Paul A. Job Checkin

Existing York unit in extremely poor condition. 100” long, 69.5” wide, and 34” high. 3 phase 240 volt electric, natural gas. Roof opening is 63” wide by 92.” Unit was commissioned in 1994. All nameplate data is too worn to even get a model or serial number. Found an old installation manual that covers several different models. We will have to do extra research to cross reference this unit in order to provide an accurate replacement quote. Crane will need about 40 feet height with a 25-30 foot reach in. The rear parking lot would be the access for the crane.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!


Keith R.

Keith R. Job Checkin

Performed an air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business! This was free with install.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed a 2nd floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years thank you for business!


Matthew M.

Matthew M. Job Checkin

Installed new Lennox condenser and evaporator coil. Project included new condenser pad, and new high voltage disconnect box with new high voltage whip. Adapted to an flushed line set. And adapted to drain. Cut out exhaust vents and reinstalled to put evaporator coil into place. Installed new t4 thermostat. Filter size 16x25x1


Keith R.

Keith R. Job Checkin

Performed a dryer vent cleaning from inside using brushes and nikro vac. Dryer vent,duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business! Pics included for back draft preventor estimate.


Paul A.

Paul A. Job Checkin

On arrival there was heavy rain and thunderstorms so I did a quick evaluation inside. Replaced customer supplied 16x25x1 air filter. I immediately knew that this is a refrigerant issue. The indoor coil unit is not frozen, and the drain line is clear and draining water properly at this time. In between the rain, I was able to add easyseal w/uv dye to the system and 4 lbs of R-410a refrigerant. My ending pressures were 278/129 with an 8 degree subcool and 15 degree superheat which is ideal for this system. Started with a 3 degree temperature split and ended with 17. I did advise the homeowner to monitor the system. System is currently operating properly at this time. Chud installed full system 07/23/2014. ***There is an estimate to do a leak search should the homeowner choose to. Easyseal is not a guaranteed fix if the leak is substantial. There is also an estimate to chemically clean the outdoor condenser coil. Weather conditions today were not in favor of doing that type of work. A d


Frank B.

Frank B. Job Checkin

Customer called for air conditioning that starts to cool but then starts to get hot. It then trips the breaker and shuts down. Upon inspection I found the system running with high head pressure (285psi) as well as the condenser fan running in reverse. Inspected the compressor/fan motor capacitor. Capacitor was rated for 35+5. It’s actual reading was 27/.2. This shows that the capacitor was causing high amp draw and needed to be replaced. Customer supplied new capacitor and system ran as it should. Amp draw for fan motor and compressor came down to normal range. Head pressure dropped significantly to 242psi. System is now operating properly at this time. This is a BILL OUT - PO# WTN59395580.


Paul A.

Paul A. Job Checkin

No ac call for apartment #703 (Reading Circle). Maintenance staff advised new capacitors and a hard start kit was already used to address the compressor not cooling. Verified amperage from the compressor, however it is NOT pumping refrigerant, therefore it will not cool. Based on age and condition the unit will need to be replaced. ***Please note the maintenance department for this location orders and installs their own equipment.*** No follow up needed from Chud. National Comfort gas package unit M#CPG2451-B, S#34654848. (R-22) Filter size-16x25x1. **********BILLOUT***********


Frank B.

Frank B. Job Checkin

Came out to diagnose a through the wall ac/heating unit that’s not running the blower on a call for air conditioning. Upon inspection I found an issue with the thermostat not coming kicking on the system when calling for cooling as well as the blower speed tap board only working on certain taps. Replaced the thermostat supplied by the customer and moved the blower speed to high (red) terminal. Air conditioning came on without issue. I then tested the heat to make sure the whole system is still operating fine. Had to move the heat blower speed wire to the high (red) terminal as well. System is operating properly at this time.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Installed new filter provided by customer. Recommend duct cleaning every 3-4 years. Thank you for your business!