1570 Old York Road
Abington, PA 19001
215-659-4343

Local Reviews
for lansdale, pa

Rated 4.9 out of 5 stars based on 7 customer reviews

Fabulous as always!

I have absolutely no complaints with CHUD and their totally professional techs!! Always quick and reliable and super friendly too!! Thank you for a great service!!!


Response from Chud Air Conditioning & Heating:

Kathy, we are so happy that you had a great experience with us! We appreciate the great review and look forward to working with you again soon.

  • Overall Experience
  • Quality
  • Price
  • Convenience

CHUD excellence

Always professional, always on time and love that everything is explained in terms I can understand. Thanks so much!!!


Response from Chud Air Conditioning & Heating:

Kathy, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

CHUD

Fantastic & professional, we love this company


Response from Chud Air Conditioning & Heating:

Aww, thanks Kathy! Chud loves our customers too.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exceptional, super friendly

Keith and his assistant were pleasant and efficient! We had our duct work and dryer vent cleaned out.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Rosie, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service. Good price.

Very friendly and courteous.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great service and fairly priced.


Response from Chud Air Conditioning & Heating:

We always strive for 5, please give us a call at 215-659-4343 to let us know what we could have done to get that 5th star.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Top Notch!!

Fantastic!! Complete professionals, super efficient and very friendly crew. We will highly recommend CHUD! We are thankful and grateful!


Response from Chud Air Conditioning & Heating:

Thanks for the awesome review Kathy. We appreciate it!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lansdale, pa

Shane A.

Shane A. Job Checkin

Manufacturer Fujitsu Model # AOU36RLXFZ1 Serial # LXN 058129 Completed a preventative maintenance on a 4 zone mini split. Washed off all of the filters. Then made sure each unit is draining properly. Performed a amperage check on the condenser fan motor and compressor both are running properly at this point.


Paul A.

Paul A. Job Checkin

Performed a first floor dryer vent cleaning. Dryer vent,duct,flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Paul A.

Paul A. Job Checkin

This proposal is for 189 dryer vent cleanings and 189 Ac inspections. There must be roof access such as a roof hatch to access the Ac systems We will be providing a lift to access the dryer vents and do the cleanings. If any landscape gets Damaged by the lift we can not be held responsible.


Paul A.

Paul A. Job Checkin

6 buildings 189 dryer vents 189 Electric heat/AC


Christian C.

Christian C. Job Checkin

Performed preventative maintenance on a Lennox furnace. Upon arrival I bumped the temperature on the thermostat up and watched system cycle on with a call for heat. I took a combustion analysis test and got the following: O2 is 11.3% and the CO is 9ppm. I took amp readings on the inducer motor and blower motor, both are in good range. Checked and cleaned the flame sensor of any carbon build up. Checked all electrical components to ensure the connections are good and tight. I also checked the drain line to confirm that there are no clogs. Checked operation of pressure switches. Checked and swept out burner box of all debris. Watched system cycle off when temperature was reached. Returned thermostat to homeowners desired temperature. System is operating properly at this time. Model # Sl280uH090v36B Serial # 5914F31297


Keith R.

Keith R. Job Checkin

Replaced backdraft damper and used tape to set the pins in place in case f high winds.


Frank B.

Frank B. Job Checkin

Customer called for no heat. Former owners of this house used chud as hvac technicians. Upon inspection, I found that the pilot light was out in the old York furnace. Thermocouple was replaced Feb 2022. Was able to relight the pilot and clear the pilot assembly of debris. Tested system upon completion. System is operating as it should at this time. Spoke in depth with customer that it is time to update the furnace due to age and condition. Furnace is 30 years old and air conditioning is 20 years old. AC was updated by Chud in 2003 but is now obsolete equipment. Customer is interested in getting a quote for a new system after I explain the age and condition of everything. I will forward customers information to Steve our comfort advisor to follow up with an <br> Manufacturer York Model #P4UGD012N08001A Serial #ELYM147520


Shane A.

Shane A. Job Checkin

Did a preventative maintenance on a boiler. During the maintenance I did combustion test the ppm was 34 and the o2 was 9. Checked the expansion tank. Made sure that the return was coming back hot. Did a amp check on the circulator and that was .61 and rated for 0.74. Took out all the burners cleaned them out and inspected the pilot assembly. System is operating properly at this time. M#CGa-4 PIDN s#CP7469916


Keith R.

Keith R. Job Checkin

Performed a first floor dryer vent cleaning. Dryer vent, duct flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business! Existing flex hose in the basement is out of code and will need to be replaced.


Keith R.

Keith R. Job Checkin

Installed a new backdraft damper into the flex line to prevent the wind from making noise and blowing the lint back into the dryer. Everything is firmly in place and dryer has proper exhaust flow. Thank you for your business!


Paul A.

Paul A. Job Checkin

Do they preventative maintenance on a four zone mini split heat pump. During the maintenance I cleaned all filters in the air handler‘s. Then turned on the heat to make sure they were all working properly. Then went outside borrow the heat pump check temperatures and pressures to make sure all the refrigerant was good which it was. Made sure all drains were unclogged. System is running properly at this time. M#ASU9RLF1 s#MXA 252562 m#ASU7RLF1 s#MWA 179202 m#ASU7RLF1 s#MWA 179677 m#ASU15RLF1 s#JWA 015314 m#AOU36RLXFZ1 s#LXN 058129


Paul A.

Paul A. Job Checkin

Preventative maintenance on a Bryant standard efficiency gas furnace. Combustion analysis performed CO PPM 6. Homeowner replaced his own MERV 11-16x25x4 air filter. System was short cycling and addressed the issue by decreasing the gas pressure. The current temperature rise 33 degrees, manufacturer specs call for 30-60. There is a bypass humidifier mounted on supply plenum and connected to return drop. Completed the service on humidifier (#35 water panel Chud supplied). Humidifier was wired incorrectly. Corrected issue and tested for proper operation. System is now operating properly and not short cycling. Today’s charges are for the humidifier service and to rewire humidifier. Bryant gas furnace M#800SA60110E21A-A, S#4320A31164. Filter size-MERV 11-16x25x4 (3M Brand). #35 water panel in fall. ***PM HT was paid on 08/22/22 and collected by JD.*** Discussed adding a 2nd system. There is attic space available. This would involve adding all new ductwork, registers and also discussing


Paul A.

Paul A. Job Checkin

Quote to be provided to replace existing Carrier 3 phase, 208/230 volt gas package unit. Customer believes it is 15 ton, however we will research the model and serial number. The existing unit is already sitting on a curb adapter. The actual roof opening is 116” by 85” and the existing unit sits on an adapter that is 17” high off of the roof opening. The forks on the Carrier are 86” wide and 91-1/4” long. The existing unit is screwed down to the adapter and the gas shutoff is covered in roof muck/sealant. It’s likely that we’ll need a custom adapter made with the same measurements that will transition to fit a replacement unit. Pictures in ST. Has economizer. The existing unit condenser coil fins are all smashed in. Customer reported that kids sometimes do get on top of the roof here and may have vandalized the equipment. The existing Carrier model number is M#48HJF017 - - - 5A1AA and the serial number is 0504F14359. Crane height 40 feet with about a 40 foot reach in.


Paul A.

Paul A. Job Checkin

Existing York unit in extremely poor condition. 100” long, 69.5” wide, and 34” high. 3 phase 240 volt electric, natural gas. Roof opening is 63” wide by 92.” Unit was commissioned in 1994. All nameplate data is too worn to even get a model or serial number. Found an old installation manual that covers several different models. We will have to do extra research to cross reference this unit in order to provide an accurate replacement quote. Crane will need about 40 feet height with a 25-30 foot reach in. The rear parking lot would be the access for the crane.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!