Paul T.

Paul T.


Job Checkin

Came out today for a no ac call. Upon inspection I found the carrier system calling for a but the condenser would not come on. Model #38TKB024300, serial #1498E2066. Upon further inspection I found that the capacitor was extremely bloated. I replace the capacitor and the system started right up. The temperature split is now at a 20° differential and is operating properly. I explained to the homeowner that his system is 25 years old and is in rough condition. The homeowner is aware of the condition of his system and is not looking to update the system. Chud cannot Guarantee that the system continue to operate problem free.