Matthew M.

Matthew M. Job Checkin

Removed 3 check valves and added 3 spirovent air eliminators. Added new check valve. Purged all air from system and checked for proper operation. 0012 circulator appears to be seized up and now moving water. Will need to return to replace circulator and check for properl operation. No charge for today. P.A. Is aware of current situation.


Paul A.

Paul A. Job Checkin

Scope of work. Drain system. Replace (1) Taco 223 (2” right angle flo-check that is leaking. Replace flanges for taco 0012 circulator pump. Re-wire in line voltage for that pump. Add (2)-1-1/4” sprirovents to each boiler supply line at boiler’s. Remove (2) taco right angle flo-checks since the circulator pumps are equipped with “IFC’s” and repipe with 1-1/2” copper. We will need to solder the 2” and 1-1/2” fittings since the press jaws only go up to 1-1/4”. All materials are ordered through John M. who manages the Ferguson branch in Abington. All materials will be available for pickup Thursday morning by 8 at the branch. After modifications are completed, the system will need to filled and purged/vented again for proper operation. The nuisance issues are a result of old check valves sticking. The house heat had to be shut down today due to the leak. The hot water was left in operation. <br> Materials list consists of: 1-1/4” through 2” copper pipe, assorted fittings to complete the wor


Shane A.

Shane A. Job Checkin

Customer had not hot water. Their was air in the line. After bleeding the system out customer had hot water. System is operating properly at this point. M#Aqua plus 45 s2<br> s#CP7696328 chud will be in contact with customer to resolve this problem.


Paul A.

Paul A. Job Checkin

Returned to complete the low voltage wiring for taco and tekmar control. Made necessary adjustments to low voltage wiring. There is an emergency Tekmar control on site for future use on this system. The part was included with the installation. Balance was collected on 12/23/22 for this job. We tested the system several times to verify water is heating properly and radiators are free of air. N/C, part of install.


Paul A.

Paul A. Job Checkin

Purged air from indirect water heater tank. This is a new install of (2) Weil McLain CGA-6 gas boilers. The updated Tekmar control is expected to come in tomorrow. We will schedule the return visit accordingly, depending on what time we receive the updated control. The customer currently has heat and hot water, however the job is not complete until new control is installed. N/C, WARRANTY. WEIL MCLAIN AQUA PLUS, CP7696328.


Matthew M.

Matthew M. Job Checkin

Completed double Weil McLain boiler install. Adapted to existing plumbing, flue pipe, gas pipe. Installed new taco zone control, 3 new circulator pumps. Installed aqua-plus temperature control. Replaced two thermostats. Installed amtrol expansion tank. Bled all air from system. Tested and cycled boilers. Boilers are working properly at this time ** Need to return to replace takmar Smart Control module under warranty, we will need to schedule return visit to replace. Boiler Model # CGa-6 PIDN Boiler serial # CP8054819 Boiler model # CGa-6 PIDN Boiler Serial # CP8043335


Shane A.

Shane A. Job Checkin

Went to a no hot water call. It was not a problem with water heater pilot was out on the boiler. After zone one was not calling for heat. Zone control board is bad. So is temperature relay on the indirect water heater. Customer did not want to do the repair he wants both boilers replaced. M#Aqua plus 45 s2 s#Cp7696328


Keith R.

Keith R. Job Checkin

Performed dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years.


Paul T.

Paul T. Job Checkin

Remove and replace failed high pressure switch. Order 86m36 pressure switch and a tee fitting to add pressure switch externally on the liquid line due to factory switch being brazed on.


Paul T.

Paul T. Job Checkin

Came out today for a no AC call. Upon inspection I found the indoor unit operating but the out door unit was not operating. I tested to insure the unit was getting the proper volt and found that there was 24 volts going into the high pressure switch but not coming out to pull in the contactor. I tried to reset the high pressure switch several times with no success. I then bypassed the pressure switch and the unit started right up. The pressure switch has failed and needs to be replaced. Order pressure switch and a tee fitting to add the switch externally on the liquid line due to the factory switch being brazed on.