1570 Old York Road
Abington, PA 19001
215-659-4343

Local Reviews
for wyncote, pa

Rated 4.9 out of 5 stars based on 13 customer reviews

Excellent company and service

Timely excellent service Quick and efficient!


Response from Chud Air Conditioning & Heating:

Scott, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good information.

I had lots of questions about our units and Paul answered them all, including showing me how to maintain the filters in our new split.


Response from Chud Air Conditioning & Heating:

We’re so grateful for your 5-star review. We strive to offer the best experience possible, and your review tells us that we’re on the right path.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great, fast service


Response from Chud Air Conditioning & Heating:

Arthur, thank you for the 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

service tune up


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Joan. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional


Response from Chud Air Conditioning & Heating:

5 stars, thank you Alex!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt service


Response from Chud Air Conditioning & Heating:

5 stars, thank you Alex!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great sery


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Deborah. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

On time and fantastic service

Highly professional and great work.


Response from Chud Air Conditioning & Heating:

Hi Tamara, we appreciate the good review. Chud works hard to create a good experience and reviews like this make it all worth it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chud services


Response from Chud Air Conditioning & Heating:

5 stars, thank you Arthur & Julie!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thank you for sending the same person as before ho was familiar with my set up

But i can't access copy of my invoice so please send one.


Response from Chud Air Conditioning & Heating:

Invoice resent. Thank you for the 5 star review Joan, Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Frank is wonderful


Response from Chud Air Conditioning & Heating:

Thank you for leaving the 5 star review Sally! Frank and everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

5 Excellent workmanship and gentlemen Couldn't be more pleased


Response from Chud Air Conditioning & Heating:

Thank you for the kind words and review Scott!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work-thorough


Response from Chud Air Conditioning & Heating:

Hi Don, 4 stars, please give us a call to let us know what we could have done better, 215-659-4343.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wyncote, pa

Keith R.

Keith R. Job Checkin

Performed a first floor dryer vent cleaning and removed a substantial clog using the drill/brush system froze the inside and the skipper line from the outside. Dryer vent, duct, flex duct and lint trap are all clear of lint and debris at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Shane A.

Shane A. Job Checkin

Navien - M# NCB-240E - S# 6610A20Y1181053 Completed the preventative maintenance on a 2 year old boiler. Turned the unit on and the system started right up. Performed a amperage reading on the inducer motor it was 0.3 amps. Cleaned the flame sensor, spark ignition and burner compartment. Cleared condensate pump and confirmed draining properly. System is operating as per the manufacturer specifications.


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a carrier furnace model #58sta090-16, serial #1918A16292. Upon arrival the system was off so I turned off the power and removed the access panels. I removed the igniter and flame sensor. Cleaned out the burners and burner box. The flame sensor is in very rough shape. Checked all electrical components to ensure that they are secure and in good condition. I did find some thermostat low voltage wire that were tied together but not capped off. I used wire nuts to cap off the low voltage wires. The homeowner replaces their own air filter size 16x25x4. I reinstalled the access panel and powered the system back up. I called for heat and took a combustion analysis test. I received the following results, o2 is at 8.5% and the co levels are 16ppm. The homeowner requested that I check the incoming gas fittings for leaks. I performed a bubble test and found no leaks. Performed preventative maintenance for a carrier ac system serial #2318E16343 model #24abc6


Shane A.

Shane A. Job Checkin

Disconnect condenser. Removed high voltage and low voltage wiring. Pumped down the system and taped of all both side of the line set. Chud will collect payment when contractor are done work and unit is reinstalled. Tested heat to make sure it was operating properly and it was. Manufacturer Goodman Model # GSX160421 Serial # 2203055779


Paul T.

Paul T. Job Checkin

Upon arrival i knocked on the door and rang the doorbell. The homeowner answered the ring doorbell and stated that her husband was inside. She asked me to knock on the door a little bit harder. I did after about 15 minutes of no response. The homeowner stated that she will need to reschedule this call. No services were performed today.


Matthew M.

Matthew M. Job Checkin

Completed Bradford white 50 gallon electric hot water heater replacement. Replaced st 5 expansion tank. Bled all air from water lines in house. Cycled and tested, system working properly at this time.


Paul T.

Paul T. Job Checkin

Came to replace Bradford White 40 gal tall chimney vent water heater. Upon arrival, we drained old water heater, cut it out and removed it from the space. We adapted to existing copper water piping, gas piping, and flue pipe. We installed 2 pro press ball valves for water heater isolation if needed. We also installed a #5 expansion tank to the system. After full installation, we lit the pilot and filled the new water heater up. System is working properly at this time. Model # RG240T6N Serial # YL50569894 Homeowner has a $30 off coupon from the chud website. Price reflected below.


Paul T.

Paul T. Job Checkin

Came out today to look at a leaking hot water heater. Upon arrival I found a large puddle of water on the floor. The homeowner showed me that the gate valve was leaking while in the off position. The system seems to still leak from the inside even with the incoming water shut off. The hot water heater will ultimately need to be replaced. The hot water heater is currently 9 years old. 2 techs needed due to stairs. See estimate for details.


Shane A.

Shane A. Job Checkin

Did a Maintenance on a gas furnace. Cleaned the flame sensor, an inducer port. Also, cleaned the blower motor housing and the burner compartment. Did a amp check on the inducer and blower motor both are in rang. Did a combustion test the CO was 43 customer changed the 20x25x1 filter. System is operating properly at this time. M#G8mxn1352420a2 s# a123215436


Christian C.

Christian C. Job Checkin

Came out to perform diagnostic work on a Crown boiler that Chud installed in 2006. The unit has outdated Honeywell style zone valves and lots of rust and wear. We located a thermostat in a portion of the home that the homeowner doesn’t use, which turned out to be a heating thermostat. As soon as we turned it on the cold radiators started to heat up. The homeowner had to leave for work and we were not able to spend any additional time with diagnostic today. I advised the homeowner that the boiler should be upgraded due to age and condition. The homeowner advised me that he will reach back out to us if he needs additional services. He was in agreement with paying the diagnostic charge, even though we could not complete a full system analysis.<br> <br> Crown gas boiler (2 zone) M#AWI128ENST1PSU, S#CROWNB000357881. ****Customer stated he will contact if additional services are needed.****


Paul T.

Paul T. Job Checkin

Came out today for a leaking issue on a Lennox furnace model #G50UH-60D-135-03, serial #5802E38041. Upon arrival the homeowner stated that the drain line was leaking. Upon inspection I tested the drain line with several bottles of water to see if the system was clogged or leaking. The system was leaking at the 90° elbow. I cut out the elbow and installed a new one the caused the drain line to move 2 inches to the left. Once the pvc glue was dry I tested the drain line with several bottles of water. In my professional opinion I believe that the drain line froze from the cold weather over the weekend and this caused the pvc elbow to crack. The system is operating properly at this time.


Frank B.

Frank B. Job Checkin

Replaced the control board and blower motor module on a Goodman furnace that was installed in 8/22. Currently the system shows signs of slight water damage in the bottom compartment of the furnace. Found the control board had blown components due to moisture. Tested the system upon completion. System is operating properly at this time. Goodman furnace model #GM9C801005CN, serial #2205022463. The system is four months old and is under warranty.


Christian C.

Christian C. Job Checkin

Performed preventative maintenance on a Lennox furnace.. upon arrival I watched the system cycle on with a call for heat. I checked and cleaned flame sensor of any carbon. I brushed out burner compartment. I checked operation of pressure switches. Replaced filter sized 16x25x1. I checked all electrical components to ensure the connections are good. Took amp readings on inducer and blower motor and both are in good range. Checked operation of condensate pump. Watched system cycle off when temperature was reached. Returned thermostat to the homeowners desired temperature. System is working properly at this time. Model # G60UH-48C-110-10 Serial # 5911G19305 Filter - 16x25x1


Paul T.

Paul T. Job Checkin

Came out today for a no heat call on a goo System that chud installed in 8/22. Model #GM9C801005CN, serial #2205022463. Upon arrival the system was calling for heat but was not operating. I opened the access panels to look inside. Upon inspection I found that the control board was receiving power and passing power but the led light would not come on. I went to the thermostat and turned the heat off and set the fan for on. The furnace still did nothing. I checked for voltage at the terminals between g and c and received a reading of 24volts. I disconnected the mulex plug from the blower to check the voltage and it was receiving 120volts. As I was looking around I placed my hand on top of the board and found water. There are dried water spots on the back plate that holds the control board as well as the roof of the bottom compartment of the furnace. I checked the burner box, inducer and flue for any signs of water but it was all dry. When it rains the basement does take in some water. It


Frank B.

Frank B. Job Checkin

Installed OEM igniter on existing gas boiler. Completed system maintenance which includes cleaning trap and combustion analysis. Cleaned the burners and burner compartment. Performed the combustion analysis on the efficiency boiler. System is operating at 93% efficiency with a CO level of 10 ppm. Inspected all four zones and gas piping. System is operating properly at this time. Weil McLain GV90+, CP6480561