1570 Old York Road
Abington, PA 19001
215-659-4343

Our Top Cities


Local Reviews
for wyncote, pa

Rated 4.9 out of 5 stars based on 7 customer reviews

Great sery


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Deborah. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

On time and fantastic service

Highly professional and great work.


Response from Chud Air Conditioning & Heating:

Hi Tamara, we appreciate the good review. Chud works hard to create a good experience and reviews like this make it all worth it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Chud services


Response from Chud Air Conditioning & Heating:

5 stars, thank you Arthur & Julie!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thank you for sending the same person as before ho was familiar with my set up

But i can't access copy of my invoice so please send one.


Response from Chud Air Conditioning & Heating:

Invoice resent. Thank you for the 5 star review Joan, Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Frank is wonderful


Response from Chud Air Conditioning & Heating:

Thank you for leaving the 5 star review Sally! Frank and everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

5 Excellent workmanship and gentlemen Couldn't be more pleased


Response from Chud Air Conditioning & Heating:

Thank you for the kind words and review Scott!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work-thorough


Response from Chud Air Conditioning & Heating:

Hi Don, 4 stars, please give us a call to let us know what we could have done better, 215-659-4343.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wyncote, pa

Paul T.

Paul T. Job Checkin

Came out today to apply high temp cement around the flue pipe. Upon arrival the homeowner showed me the issue. I powered the system down and removed any loose dirt or debris from around the flue pipe. I added some support to the flue pipe to help prevent this from happening again. I applied new cement to the damaged area. I advised the homeowner that the cement will need time to cure. The system is operating properly at this time. See photos.


Keith R.

Keith R. Job Checkin

Performed 2nd floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Frank B.

Frank B. Job Checkin

Came out to replace the air filter with the proper Merv 16 20x25x5 air filter that we didn’t have during the maintenance. No charge due to customer prepaid for filter during the maintenance visit last week. System is operating properly at this time.


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Lennox furnace model #G60uh-60d-135-10, serial #5911G08289. Powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor, cleaned out the burners and burner box. The correct air filter size is 20x25x5 Merv 16. I currently have the wrong size Merv air filter and will have to return with the proper size. I placed a 20x25x1 air filter in the system until I can return. Checked all electrical connections to ensure that they are secure and in good condition. Performed humidifier service for an Aprilaire humidifier model 600 series. I removed and replaced the old #35 water panel. I cleaned out the housing and drain. Tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. I powered the system up and called for heat. Took a combustion analysis test and received the following readings, o2 is at 12.6% and the co levels are 5ppm. The inducer amp draw is


Paul T.

Paul T. Job Checkin

Came out today for a Lennox furnace not operating. Upon inspection I found that the 2 furnaces were twinning furnaces. System #2 was trying to operate but there was an issue with system #1. System #1 has an error code open rollout switch. I took my volt meter and checked each switch. I received a reading of 27 volts at each switch going in and coming out. I proceeded to jump out each switch one by one and try to start the system. I had no success. I jumped them out at the same time and fired up the system. The control board is still giving an error code for a rollout switch. This is an indication that the system has a bad control board. The system is currently 21 years old and tracking down a new board may be an issue. I was able to bypass the second system so the homeowner would have heat. Chud will have to reach out to the homeowner with a proper repair quote. Lennox furnace model #g50uh-36b-090-02, serial #5801j52882. See photos


Keith R.

Keith R. Job Checkin

Performed rooftop dryer vent cleaning from the inside using the brushes and shop vac. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is s functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Keith R.

Keith R. Job Checkin

Performed a 2nd floor dryer vent cleaning. Dryer vent,duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Keith R.

Keith R. Job Checkin

Performed a second floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Frank B.

Frank B. Job Checkin

Returned to install watchdog battery back up for sump pump system. Hooked up all necessary wires and mounted them cleanly. Installed the marine battery into its protective case and tested operation. Primary and secondary sump pumps are operating without issue. No charge for visit to install battery due to cost of this accessory was included with the new heat/cool system install. System is operating properly at this time.


Matthew M.

Matthew M. Job Checkin

Completed full Goodman system installation. Furnace, condenser, and coil. Adapted to existing ductwork, gas line, flue, and lineset. Flushed lineset. Ran new pvc drain, flue pipe, and replaced thermostat with Honeywell T4. Outside replaced disconnect box, whip, and pad. Replaced customers sump pump, but will need to return to install back up battery. Added new receptacle for sump pump and tested. Cycled and tested hvac system, system working properly at this time. Will need to return.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. Blower motor is functioning but unit is not. New unit being installed tomorrow. Recommend duct cleaning every 3-4 years. This was free with install.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!


Matthew M.

Matthew M. Job Checkin

Completed full Goodman system installation. Inside replaced thermostat with Honeywell T4. Flushed lineset and adapted to existing lineset, gas line, electrical, and ductwork. Ran new flue piping to chimney. Added (2) 16x25x1 filter racks and filters. Ran new pvc drain. Outside replaced disconnect box, whip, and pad. Cycled and tested, system working properly at this time.


Frank B.

Frank B. Job Checkin

Customer called due to air conditioner not operating after having a frozen coil yesterday and needed it to thaw. Being that the system is now fully filled out once I turned it on to get it going everything started up but the blower motor is making a high pitch noise. Upon inspection I found that the blower wheel was shredded into pieces due to age and lack of airflow. We will need to get a price on a new blower motor and wheel to fix this issue. Since the units older we would have to track down the blower wheel necessary for this brand of unit. Unfortunately system is not functional at this point until we get a hold of the parts. We will follow up on pricing for this repair once we track down the blower motor and wheel. After speaking with the customer she is concerned about having more major issues in the future if we were to repair it. She would like a quote to replace the system and decide from there. No charge for a visit today due to call back from yesterday 7–20–22.


Sebastian R.

Sebastian R. Job Checkin

Came out for a no AC call. Upon arrival discovered two fully restricted filters. Took the filters out and replace them with new ones. The unit was frozen up due to airflow restriction the customer was instructed to let the system thaw out and run it again with the filters in if the problem continues to call the office back. Filter size- 16x25x1 (2)