John is always prompt and professional.
John is always pleasant and makes sure everything is correct and compares the current readings with past to insure everything is working properly and makes suggestions when needed.
You do a great job of communicating with your customers. And it's clear that you value your customers' business as well as their time. Sean has serviced my heating/cooling system a couple of times and is always top notch in his professionalism.
Addressed issues with furnace and humidifier. Made setting changes to reduce cost of heating and also took time to educate me on the thermostat features.
John is always prompt and professional when he services our Furnace and A/C. Very polite and caring of our house when he comes in. Always gives suggestions and compliments when he notices little things like a clean air filter.
Corey was probably the most outstanding Classic Aire has sent to my home.
John is always prompt and does a completed job of checking and communicating when his job is completed. I would not have anyone else.
This technician knew his business. He found issues missed by others. Thorough, and polite. I will be using Classic Aire and John, from now on, for servicing my home HVAC systems.
Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 5.2A . Inducer: 1.9A . Gas pressure: 3.5 inches water column. Temperature rise: 61.
Clean and check electric furnace. Tested heating elements. Tested sequencers. tested air flow: 600. Checked temperature rise. 44. Supply: 114. Return: 70. Voltage: 244. Amps: 33.5. Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Checked drain. Replaced air filter. Blower: 2.9A. Inducer: 0.26A. Gas pressure: 1.85/3.5 inches water column. Temperature rise: 44 . Supply: 126 . Return: 73 . Clean and check humidifier, replace pad, checked water flow and drain. Found solenoid valve restricted and not shutting off all the way. I replaced solenoid valve under parts warranty.
Replaced warranty gas valve. Good to go!
I replaced wireless thermostat and equipment interface module. Set up thermostat for heat pump operation. 1C, 3H. Cleaned and checked heat pump/elec. furn. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Tested heating elements. 78A. Compressor: 14.5A . Condenser fan: 1.07A . ambient: 58 . liquid line: 97. suction line: 60 . metering device: TXV . Return air: 79. supply air: 107. Stage III : temperature rise: 64. return: 80. Supply: 144.
Cleaned & checked 3 condensing gas furnaces. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitors. Main system: cleaned electronic air cleaner. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 4.5/5.8A . Inducer: 0.34/.056A . Gas pressure: 1.8/3.5inches water column. MBR: Cleaned electronic air cleaner. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 2.0/3.1A. Inducer: 0.34/0.56A . Gas pressure: 1.9/3.6 inches water column. Second floor system: cleaned filter. Blower: 4.1A . Inducer: .62A . Gas pressure: 1.8/3.5 inches water column.
Mid season check up for the HVAC system! Good to go
Cleaned and checked 2 air conditioners. Checked drains. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon levels. Cleaned condenser coils. Checked filters. Main floor system: Found blower run capacitor weak: 42%low! Replaced capacitor and tested amp draw. Compressor: 10A . Condenser fan: 1.2A . Blower:was9.4A . ambient: 76 . liquid line: 80, dirty . suction line: 52 . metering device: TXV . Suction pressure:113(36) . Return air: 70 . supply air: 49.5 . wet bulb: 58 . Basement system: Compressor: 5.45A . Condenser fan: 0.79A . Blower: 4.0A . ambient: 76 . liquid line: 79 . suction line: 56 . metering device: TXV . Return air: 69.5. supply air: 51 . wet bulb: 58 .
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced air filter. Compressor: 8.9a/12.4A . Condenser fan: 0.96A . Blower: add 10%. 1540. ambient: 87 . liquid line: 93 . suction line: 49. metering device: TXV . Suction pressure: 119(41) . Return air: 71 . supply air: was43.5/45.5 . wet bulb: 58 . Found dual run capacitor weak: 12%low, fan side. Replaced capacitor under parts and labor warranty and tested amp draw.
Basement system: replaced blower motor. Tested cooling operation. Compressor: 16.2A . Condenser fan: 1.52A . Blower: L. ambient: 80 . liquid line: 86. suction line: 51. metering device: TXV. First floor system: reclaimed 410A Freon. 13lbs. Replaced grounded compressor. Pressure tested connections @285psi. Evacuate system and recharge. Replaced air filter. Compressor:17A. Condenser fan: 1.25A . Blower: 1750 . ambient: 86. liquid line: 95 . suction line: 54 . metering device: TXV Suction pressure: 125(43) . head pressure: 330(103) . Second floor system: Replaced air filter. Master bedroom system: Replaced thermostat batteries. Work suggested: Need to schedule first clean and check for new PMA.
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Checked filter. Compressor: 14.7A . Condenser fan: 1.35A . ambient: 87. liquid line: 91. suction line: 47 . metering device: TXV . Suction pressure: 79(41) . Return air: 72 . supply air: 53 . wet bulb: 59.
I found second floor system evaporator coil completely iced up. Leak detector indicating an evaporator leak. I weighed in 3 pounds of 4 10A for temporary cooling after system is thawed. Warranty no charge. Need to order new coil to install ASAP. Need to check mechanical fittings upon return. Turn system back on after thawed.
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced thermostat batteries. Replaced air filter. Adj water pr. Adj blower. Repaired threads at suction schraeder connection. Topped off 410A. Compressor:5.7A . Condenser fan: 0.86A. Blower: adj, 1.6A . ambient: 87 . liquid line: 93, dirty . suction line: 58. metering device: TXV . Suction pressure: 130(45). head pressure: 319(100). Return air: 76. . supply air: 56 . wet bulb: 63.
Cleaned and checked 2 air conditioners. Checked drains. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon levels. Cleaned condenser coils. Checked filters. First floor system: Replaced thermostat batteries. Found blower run capacitor weak: 17%low. Replaced capacitor and tested amp draw. Compressor: 17.9A . Condenser fan: 1.0A . Blower: 10A . ambient: 90 . liquid line: 97 . suction line: 51 . metering device: TXV . Return air:72.5 . supply air: 52.5 . wet bulb: 59 . Second floor system: Compressor: 6.5A . Condenser fan: 0.66A . Blower: 3.6A . ambient: 90 . liquid line: 92 . suction line: 54 . metering device: TXV . Return air: 71 . supply air: 53.5 . wet bulb:59 . Work suggested: Replace air filters soon.