Job Checkin

Today I came to Julie’s Altador home because there was no hot water. Upon diagnostic I found the boiler had shut off on e4 error indicating flame failure. I found the ignition and flame rectification systems are failing. The heat exchanger is badly soiled and must be cleaned. There is a leak internally on a sensor port as well as externally on the thermostatic mixing valve. The under floor heating pump has a failing impeller and is loud. The water softener is almost over flowing with water indicating the injector is failing. Julie has also mentioned that the ac has never worked correctly and has has over 10 different contractors try to fix it. Upon inspection of that system I found there is a restriction in the refrigerant and the fan coil unit is starving for air with only 2 small return air grills for 3 tons of cooling. The inside coil freezes after 2 min of operation. Julie would like options for repair and replacement. She would like me to go over the options with her husband Kir