4805 32 St SE
Calgary, AB T2B 2X3
403-216-8439

Local Reviews
for cochrane, ab

Rated 4.9 out of 5 stars based on 8 customer reviews

Great Service

Richard was knowledgeable and gave the most useful information as he could during the water tests with the washer

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent advice

Very knowledgeable and helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service but price too expensive

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, thorough

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service by John

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service by Jon

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for cochrane, ab

Heinz B.

Heinz B. Job Checkin

Client called about basement boiler zone overheating tech went out boiler is new only a couple months old tech found the living room zone and the bedroom zone thermostat wires were crossed, causing the living room to heat the bedrooms and the bedrooms to heat the living room tech swapped thermostat wires around so now the living room is controlling the living room zone and the bedroom is controlling the bedroom zone. Client is happy. Today was done under warranty.


Richard S.

Richard S. Job Checkin

Arrived onsite to clients home due to concerns with water when washing machine was running We could not re create issue I’ve explained to client the only way to be certain is to gain access through drywall and check plumbing Client is going to see if issue comes back first home psi 70


Drake A.

Drake A. Job Checkin

November 18, 2024: Drake arrived to install new Goodman 80k furnace. Removed old unit. Cored new 3” hole and ran new 3” system 636 exhaust. Piped 1/2” black iron gas line and leak checked. Installed 2 co detectors. Reused thermostat. Installed new 3/4” pvc drain line. Furnace ran for 20 mins. Gas pressures set to 1.8-3.5”wc.


Gerry H.

Gerry H. Job Checkin

Returned to Jake’s home in Cochran on Monday Nov 4 to replace control board on his main floor furnace. Replaced the board and check operation. I fpund that the exhaust blower is over amping and the thermostat has failed. Jake is going to replace the thermostat himself and is going to talk to his wife as to whether they want to replace the exhaust motors in the 2 furnaces or replace the furnaces. They will get back to us when they decide what they want to do.


Gerry H.

Gerry H. Job Checkin

I attended Jake’s Cochran home as they have no heat. After diagnostic I found that the control board is faulty. I have ordered the control board and will return Monday Nov 4 to install and finish diagnostic to ensure everything is all right.


Heinz B.

Heinz B. Job Checkin

Tech returned to replace hot water heating system with combination boiler. Tech drained a removed old system then installed new one, ran new venting and gas line, built new boiler loop and installed new pumps, expansion tank, system feeder with glycol. Adjust water line and install a prv tested system found the control board was faulty. Tech replaced the control board and tested system working well. Water pressure is 60-65 psi.


Richard S.

Richard S. Job Checkin

Return to site to complete the install of toilet in basement Clients also having issue with boiler system, set up appointment for boiler specialist tomorrow Took a look at leak under ensuite sink This is a kindred sink with a separated overflow requiring special order part for repair let clients know I will reach out early next week


Richard S.

Richard S. Job Checkin

Arrived onsite to clients home to perform heating planned service System is in great condition with Iaq upgrades and very clean No recommendations at this time


Heinz B.

Heinz B. Job Checkin

Tech returned to install replacement Axiom system feeder tech drained down boiler system and removed old system feeder tech installed new system feeder then filled the system. Tech noted there is a couple of auto air vents but no primary air separator. Tech also noticed the boiler hasn’t been flush in 8 years tech informed client and made a few options client will wait till the fall and call us back client is happy.


Richard S.

Richard S. Job Checkin

Arrived onsite due to concerns with combi boiler System psi dripping to less than 10 psi, feeder is also at 5 psi No longer under warranty Provided solution and client agreed to nee axiom feeder with family plan Deposit scheduled Appt to be scheduled with office pending parts arrival


Richard S.

Richard S. Job Checkin

Return to site to install new toilets (all) and repair water line Insurance needs to rip up basement floor so has asked to just plug drain for time being Cut water line and replace with pex and cap Install new toilet to both upstairs bathrooms with new braided supply lines and seals test and operate no issues found Client to let us know when third is ready to be set payment completed


Richard S.

Richard S. Job Checkin

Arrived onsite to clients home in Cochrane to perform plumbing planned service Home and equipment are in okay condition however psi is extremely high sitting at 120 psi, I’ve made client aware of the severity of having such high psi but he’s like to wait before doing prv at this time


Richard S.

Richard S. Job Checkin

Arrived onsite to clients home in Cochrane to perform plumbing planned service System already had protective equipment implemented psi set to 75 Water heater is approx 1 years old no issues No leaks or concerns at this time Built upgrade option to implement water conditioning system to prevent irreversible damage to system and home


John F.

John F. Job Checkin

Today I came to Blake and Lisa’s Cochrane home because they are doing renovations to the home and want a new furnace, water heater, and air conditioning system. Blake also want a new gas line to the kitchen for a new gas cook top. The home is 1088 square feet and will require a 60000 btu furnace and 2 ton ac system. The electrical panel can’t accommodate a new ac system. There is only 2 wires to the thermostat and Blake will run a 6 wire when he does the renovations. Tentatively scheduled to return Monday April 22 2024 for furnace, ac and tankless installation. Blake and Lisa have not paid a deposit at this time and will find the funds within the next week. The job can be canceled at any time however discounts will not apply past end of April. Either 50% to be collected up front or financing in place before parts can be ordered.


Gerry H.

Gerry H. Job Checkin

I attended heathers Cochran home to perform the plan service on her 15 yr old furnace in her new home. I found the ducts dirty, the condensate collector box showed signs of leaking and the furnace control board was set up for a 2 stage thermostat, but was not wired for a 2 stage thermostat. This meant the the furnace never came out of low fire. Set control board properly and ensured furnace went to high fire. Humidifier requires a new evaporator pad. The hw tank is 15 yrs old and they do not have ac.