Mark S.

Mark S. Job Checkin

On site found tested system found broken low voltage wire going to condenser. Repaired wire system is operating and cooling at this time. Recommend to add secondary back up water safety. Recommend to add surge protection to both units.


Jon F.

Jon F. Job Checkin

Found system slightly overcharged. Reclaimed refrigerant to desired superheat. Delta T in house is good. System cooling.


Jon F.

Jon F. Job Checkin

Completed diagnostic. Found capacitor outside bad. Replaced capacitor. System cooling. Amps are good pressures are good. Signed customer on maintenance. Will return to do maintenance.


Christian  S.

Christian S. Job Checkin

(Warranty) I arrived on site, found compressor not running, but fan motor operating. Checked capacitor and found it dead on Herm side, replaced under warranty and unit started operating normally. Checked pressures, unit is operating normally at this time


Christian  S.

Christian S. Job Checkin

Arrived on site to preform a one system maintenance. Indoor; checked filter and cleared drain line. Checked electrical connections, amp draw and capacitance, found blower capacitor reading low. Outside; checked coil and refrigerant pressures. Checked electrical connections, amp draw and capacitance. Recommend installing compressor assist kit due to age of system. Unit is operating within manufacture spec at this time.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Reece W.

Reece W. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Installed pureairx electronic filter and signed customer up for one system maintenance plan, will return to do maintenance later.


Vu T.

Vu T. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Find 2-year-old system in the attic with loose male connection. Replace for the customer. Check and find system operating within manufacturer spec. Close vent to reduce air to the master bedroom. Suggest comfort club membership plan.


Reece W.

Reece W. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found system overcharged. Found system with very weak capacitor leaking oil. Found burnt wiring. Found burnt main electrical switch. Found compressor running above maximum rated amperage. Found bad corrosion on condenser coil. Due to age and condition of the system, recommend upgrading system to a more reliable and more efficient system. Balanced refrigerant pressures. Replaced main electrical switch. Replaced capacitor. Current supply temp is 66 degrees. Amp draw on compressor before replacing parts was 22 amps. After replacing them it was 17. Max rated amperage is 16.1. The system is old and worn and may not last very long. The system is cooling at this time.


Reece W.

Reece W. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found clogged drain line. Found struggling condensate pump. Rebuilt drain line going to pump and replaced pump as well. System is draining at this time. Customer used $30 coupon


Jon F.

Jon F. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Completed diagnostic found blower motor failure. Lennox won't have part until Monday need to schedule Monday to come out and replace the motor.


Steve I.

Steve I. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found system low on charge. Weighed in 1.5lbs of R22 in System and was able to get better cooling. The system is old, the customer knows and should be replaced. Customer hopes to have the house sold.


Steve I.

Steve I. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

Completed 1 system maintenance found blower wheel dirty and no secondary water safety device. Changed filter. Found pressures good cleared drain line and washed off condenser found outsidesystem running with no surge protection and would benefit from having a compressorsaver installed. Also recommend an ionizer for indoor system to pick any dust that is sitting in the duct work or house to better filter it out of home.