5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for bethlehem, ga

Rated 5.0 out of 5 stars based on 1 customer reviews

Great service and follow up

Technician was on time. Called before showing up. After he was finished, the company called to follow up on his visit. Everything went smoothly and the technician was professional.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for bethlehem, ga

Reece W.

Reece W. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found system overcharged. Found system with very weak capacitor leaking oil. Found burnt wiring. Found burnt main electrical switch. Found compressor running above maximum rated amperage. Found bad corrosion on condenser coil. Due to age and condition of the system, recommend upgrading system to a more reliable and more efficient system. Balanced refrigerant pressures. Replaced main electrical switch. Replaced capacitor. Current supply temp is 66 degrees. Amp draw on compressor before replacing parts was 22 amps. After replacing them it was 17. Max rated amperage is 16.1. The system is old and worn and may not last very long. The system is cooling at this time.


Reece W.

Reece W. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found clogged drain line. Found struggling condensate pump. Rebuilt drain line going to pump and replaced pump as well. System is draining at this time. Customer used $30 coupon


Jon F.

Jon F. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Completed diagnostic found blower motor failure. Lennox won't have part until Monday need to schedule Monday to come out and replace the motor.


Steve I.

Steve I. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found system low on charge. Weighed in 1.5lbs of R22 in System and was able to get better cooling. The system is old, the customer knows and should be replaced. Customer hopes to have the house sold.


Steve I.

Steve I. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

Completed 1 system maintenance found blower wheel dirty and no secondary water safety device. Changed filter. Found pressures good cleared drain line and washed off condenser found outsidesystem running with no surge protection and would benefit from having a compressorsaver installed. Also recommend an ionizer for indoor system to pick any dust that is sitting in the duct work or house to better filter it out of home.


Reece W.

Reece W. Job Checkin

1 system ac pm check completed. Changed filter. Cleared drain line. Added chlorine tablets to evaporater coil drain pan. Found dirty blower wheel, recommend blower wheel pull and clean. Found weak blower capacitor, recommend repair. Chemically washed condenser coil. System is cooling at this time.


Jon F.

Jon F. Job Checkin

Completed 1 system furnace repair and preventative maintenance check. found unit to be running with no issues. The coil has signs of corrosion but pressures are good no sign of leak as of now. The blower wheel is dirty recommend blower wheel cleaning. The UV light is still in good age does not need to be replaced at this time.


Reece W.

Reece W. Job Checkin

1 heatpump repair and preventative maintenance check complete. Changed filter. Cleared drain line. Used brush to clean ClearVue trap. Tested mechanical and electrical components, all in good shape. Recommend surge protection to protect the system from power surges. Recommend apco air purifier to kill bacteria, germs, and viruses for improved air quality. The system is heating normally at this time.


Gavin  C.

Gavin C. Job Checkin

Installing Gsx140421 CAPF3743C6 2 year labor warranty 10 years parts


Vu T.

Vu T. Job Checkin

Add charge to main level system so customer can have cooling til install. System operating at his time.


Vu T.

Vu T. Job Checkin

No cool repair call for the main level system. Checked and found a leak at the evaporator coil in the attic. Coil badly rusted. Found a system that is 16 years old and dirty. System low charge and freezing up. The customer does not want recharge. Gave the customer estimate to upgrade system. The customer does not want to ductwork though it is undersized at duct board plenum.


Steve I.

Steve I. Job Checkin

Completed 1 system a/c repair and preventative maintenance check. The drain is clear. Replaced filters. Cleaned the condenser coil. Amps and pressures are good. Installed APCO system is AH.


Brian M.

Brian M. Job Checkin

Completed maintenance. Air Handler has mold growing in the Air movement system , reccomend installing a Apco Air Purifier to kill the mold and prevent mold from occurring. System is heating normal at this time. All electrical components are operating normal at this time.