5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Job Locations
for braselton, ga


Map of Braselton GA
Jon F.

Jon F.


Job Checkin

Completed one system tune up. Changed filter and made sure system was draining properly. Blower wheel has slight build up of dust but not enough to cause harm to system. Evap coil does have concerning amounts of rust which will start to eat away the copper and eventually cause a leak. System has no back up water safety device to protect system from water damage. System inside also has slight evidence of mold growth inside drain pan which could get into the air flow and cause harm to residents. Suggest installing UV air treatment to kill bacteria allergens and viruses in the air. Outdoor system is clean and has good pressures. All electrical components are good. System missing compressor saver to take load off compressor during start up and allow compressor to live longer.