5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for decatur, ga

Rated 5.0 out of 5 stars based on 3 customer reviews

Ta is the best!

Ta has been servicing my HVAC for about 6 years and he's wonderful! - thorough, professional, knowledgeable, and personable; going above and beyond my expectations - a rare combination in these days and times. Thank you so much, Ta!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great experience!

Comfort Control helped me out during a bind when my A/C unit stopped working in the scorching heat of July. They made every effort to come as quickly as they could and fixed the problem with great service and communication!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Ta's the Best

I always enjoy my maintenance visits from Ta. He's professional, knowledgeable, and very courteous. Please give him a raise for his outstanding work!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for decatur, ga

Ta K.

Ta K. Job Checkin

Completed 2 system furnace repair and preventative maintenance check. Replaced filters, checked electrical and safety switches all ok at this time. Flue pipe is foil wall for both furnaces and is good. Found worn ignition and weak flame safety sensor for the downstairs system. Replaced both parts. Did a combustion test and found high oxygen content for both furnaces. Did a combustion calibration for both furnaces for safety and efficiency. Installed low carbon monoxide detectors for upstair and downstair. Tested and everything heating normally at this time.


Vu T.

Vu T. Job Checkin

Completed 2 system furnace repair and preventative maintenance check. Changed both filters. Checked the safety and operations. Found both furnaces operating within manufacturer specs. Adjusted the upstairs gas pressure 3.5" w.c. to improve the temperature for the furnace. Both furnaces are operating at this time. The customer was approved for credit over the phone. The customer was not home to sign the invoice.


Ta K.

Ta K. Job Checkin

Furnace repair call. There is no heat basement system. Found pressure switch stuck open. Clean port and system is now heating normally at this time.


Vu T.

Vu T. Job Checkin

Completed 1 system furnace repair and preventative maintenance check. Change both filters, check safety and operations. Find upstairs system under fire and not meeting manufacturer spec on efficiency. Find downstairs system operating normally. Suggest calibration upstairs furnace. Both systems are operating at this time.


Reece W.

Reece W. Job Checkin

Completed 1 system furnace repair and preventative maintenance check. Did not change air cleaner filter. Tested combustion and found unsafe carbon monoxide levels at 112 ppm. Recommend recalibration. System has no secondary water safety to protect furnace from water damage, recommend adding on. Tested mechanical and electrical components and found no issues. Red flagged furnace, customer wants to wait on recalibration.


Vu T.

Vu T. Job Checkin

Complete 2 heating repair and preventative maintenance check. Did not change filter. Check safety and operations. Find system operating within manufacturer spec. Find Aprilaire thermostatstat was set for heatpump and not gas furnace. Reset tstat. System operating at this time.


Vu T.

Vu T. Job Checkin

Completed 1 system heating preventative maintenance check and furnace repair. Changed the filter. Checked the safety and operations. Found the furnace operating within manufacturer specs. No concern at this time. Need to keep checking the worn ignition due to a minor white spot on the ignition.


Ta K.

Ta K. Job Checkin

Came to house and no one home


Ta K.

Ta K. Job Checkin

3 furnace repair and preventative maintenance check complete. Replaced filters, checked electrical and safety switches all ok at this. Replaced 3 water panel and 3 UV bulbs. 3 system heating normally at this time.


Ta K.

Ta K. Job Checkin

1 system heating preventative maintenance and a new Comfort Club Membership. Replaced the filter, checked the electrical and safety switches. All are okay at this time. Performed a combustion test and found the furnace with a high oxygen content. Suggested to have the system calibrated. The owner wants to wait. The system is heating at this time.


Ta K.

Ta K. Job Checkin

1 system heating prepaid preventative maintenance. Left the filter for the owner. Checked the electrical and safety switches. All are okay at this time. The system is heating normally at this time.


Vu T.

Vu T. Job Checkin

Replace downstairs furnace blower motor, pull/clean blower wheel and assembly. Complete heating pm check for both heating system. Change filter, check safety and operations. Find both furnace operating with in manufacture spec. Both system operating at this time.


Tom K.

Tom K. Job Checkin

Found gas cock under house turned off. Repaired the broken drain line.


Vu T.

Vu T. Job Checkin

Check and find downstairs blower fail and not supply air flow causing furnace to overheat and lock out on safety. Need to order new Lennox blower motor and check on warranty. Need to call customer to confirm cost and warranty part availability. System off at this time.


Vu T.

Vu T. Job Checkin

Completed furnace repair and preventative maintenance check. Did not change the filter, check safety and operations. Find 3-year-old Lennox furnace operating normally at this time of visit.