1 system cool pm. Cleaned outdoor coil and checked all components. All electrical in good shape, system has compressor saver, indoor and outdoor has surge protection, system has back up water safety. Brand new system operation normal at this time. I do recommend ultraviolet system to boost indoor air quality, protect against viruses and combat common mold growth inside units


Vu T.

Vu T. Job Checkin

Complete 1 system A/C repair and preventative maintenance check. The system not operating. Test and find Amana furnace control board fail and not operating properly. Give customer estimate to repair system. The customer wants to wait. The customer wants to look over her options.


Vu T.

Vu T. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Check and find a heating furnace operating at this time. The customer stated that the furnace failed last night and come back in the morning. No error code on the furnace. Check safety and operations and find furnace operating at this time. Concern furnace control boards may not operating normally but do not detect problems at this time. May need to replace the control board for the upstairs furnace. Give customer estimates.


Vu T.

Vu T. Job Checkin

Tech replaced inducer assembly 12/9/2019 and now not heating again. Check and find inducer assembly tube bend causing pressure restriction. Repair tube and system operating but flame sensor also bad reading .4/1.5 rated. Replace sensor for the upstairs system. System operating at this time. Find downstairs system operating but CO level reading over 3000 ppm and detector lockout on safety. Find furnace in exchanger badly rusted and system not burning properly causing dangerous co level. Shut system off. Run system for about 20 min and the house already reading 40ppm in house. Not safe to operate. Due to bad heat exchanger, we need to replace the system.


Jordan R.

Jordan R. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Homeowner just wanted a technician to explain everything on his new systems. Did not want maintenance


Jordan R.

Jordan R. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. The main system operation normal. The sunroom system needs to be replaced. Please schedule Garrett


Jon F.

Jon F. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Steve I.

Steve I. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Found system with a fault code. The code was for locked rotor. Reset the system and was able to check. Found nothing wrong. Added a start kit to the condenser. Cycled system a few times and started up every time. Talked to customer about the Dehumidifier. He agreed and will do in the spring along with a membership.


Jordan R.

Jordan R. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Tested system operation. Ran system for 40 mins nonstop. Subcool 12, superheat 8, delta 20. Also tested heat and heat operation normal. Could not find any issues with system other than filter pretty dirty from construction.


Vu T.

Vu T. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Find a heating system operating with manufacturer spec. No concern at this time. Change filter customer provided.


Ta K.

Ta K. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Tested system and everything is working normally. I'm getting 8 degrees to superheat and airflow is at 1200 cfm on 2nd stage cooling. Was getting about 70-71 degrees in the room and nest thermostat was reading 76. The room was around 58% humidity. Need to lower the humidity to feel more comfortable.


Ta K.

Ta K. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Renew Comfort Club membership. Replaced filter and UV bulb. Checked electrical and safety switches all ok at this time. Tested heat strips and working normal. Installed compressor saver to help on startup of the compressor. The system is heating normally.


Vu T.

Vu T. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Change filter. Find water in crawlspace. Customer needs to get a plumber to check on leaking water. Clean ac coil and cut bushes around the a/c unit for the customer. Find duct system very dirty and breaking down. Insulation falling off. Find crawlspace unsanitary and not healthy air. Need to install a dehumidifier, need to remove water and clean crawlspace. Need to remove and upgrade a new duct system and need to install an air purifier system. System operating at this time.


Reece W.

Reece W. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Vu T.

Vu T. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Water leaking again from 7/5/2019 service call. Find water still leaking out of drain pan. Re-level drain line at the evaporator coil. Clear drain again and clean up water in the closet. Test with 2 gallons of water and water not dripping. Did not see water leaking at this time. Customer does not want to install a detector. Warranty service call. No charge to the customer.