5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for jefferson, ga

Rated 5.0 out of 5 stars based on 6 customer reviews

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Very knowledgeable about products and attentive to cuatomer

Garrett was very helpful answering all of my questions and explaining what our home needs.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Ta does an awesome job!!

Ta explains everything in a way is easy to understand. He shows me everything that I need to know about with the systems.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Awesome

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

Seth Delmada arrived on time and was courteous and very professional. We are very happy with our service from Comfort Control.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for jefferson, ga

Reece W.

Reece W. Job Checkin

Found system low on charge. Found leak in evaporater coil. Ordered new coil from tristate. Will return to replace coil once it comes in.


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Customer is moving shortly so will not be renewing. Found pressures for system very good. System is draining condensate properly and filter is clean. Customer had issue with freezing at evap coil due to dirty filter it is imperative to keep filter clean so that system can breathe. As of now system is running good.


Jon F.

Jon F. Job Checkin

Fan speed was higher than recommend. Switched it to low. Supply temp dropped. System is running.


Jon F.

Jon F. Job Checkin

Completed diagnostic found thermostat malfunctioning. Turning on emergency heat constantly. Switched out thermostat. System running at this time.


Vu T.

Vu T. Job Checkin

No cool upstairs. Check and find Lennox system lock out on high pressure. Reset and find system operating within manufacturer spec. Show customer how to reset Lennox heatpump lockout. Complete 2 cooling pm check. Change 2 filter and clean ac coil. Both system operating at this.


Garrett G.

Garrett G. Job Checkin

Free consultation


Jon F.

Jon F. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Found blower clean and capacitor good. Changed filter and cleared drain line. Found outside unit electrical components good. Good amps on compressor and fan. Cleaned off condenser fins and recommend surge protector and hard start kit for outside unit. System running at this time


Ta K.

Ta K. Job Checkin

1 system A/C tune-up. Left filter for the owner, cleared drain and clean condenser coil. I could not hear whistle noise/cricket noise. Only thing is some vibration in the walls in the bedroom. The owner told me about the dirty sock syndrome smell. I could not smell it and owner state it's only in heating mode. My only suggestion is installing APCO in the light system in the coil and the supply plenum. System is cooling at this time


Jon F.

Jon F. Job Checkin

Completed upgrade


Jon F.

Jon F. Job Checkin

Completed one system maintenance. Found both systems to have very dirty blowers and the upstairs system is showing signs of possible mold growth. The downstairs system to had a failing run capacitor. Also, the main level system was low on refrigerant. Filled the mail level with refrigerant and both systems are running.


Ta K.

Ta K. Job Checkin

Furnace repair for the downstairs unit. Signed the client up for a new Comfort Club Membership. Performing heating maintenance. Replaced both of the filters. The downstairs system has a warped shaft for the blower motor but it is still working but not balanced. Installed a compressor saver for both systems. The downstairs and upstairs systems are heating normally.


Reece W.

Reece W. Job Checkin

Replaced the thermostat. Signed the customer up for one Comfort Club Membership plan and completed heating maintenance. Left a replacement filter. Tested the mechanical and electrical components and found a weak capacitor. Recommended repairing. Recommended a hard start kit to reduce the load on the compressor. The system is heating at this time.


Steve I.

Steve I. Job Checkin

Replaced defrost board and sensor. Tested system and found to be heating good. Part is under warranty, charged for labor.


Steve I.

Steve I. Job Checkin

Completed heating maint. Filter is clean. Replaced the capacitor and contactor in the condenser. System is getting up in age but working good.


Steve I.

Steve I. Job Checkin

Diagnosed system. Found charge to be good. Error code was stating the pressure switches are cycling, time delay/control board failure, thermostat short cycle. Ran system in both cooling and heating. Talking with the customer. Determined the defrost board is malfunctioning. Order new board and schedule for following Mon 10-12 to replace.