5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for johns creek, ga

Rated 2.0 out of 5 stars based on 1 customer reviews

Below Average

No difference before and after the service, same issue with the A/C cooling.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for johns creek, ga

Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Steve I.

Steve I. Job Checkin

Installed APCO SI in supply plenum along with single UV to kill biological growth supply. Setup lead for CA to go out and give options for adding a system to the basement and replacing main system in house.


Steve I.

Steve I. Job Checkin

Completed heating maintenance. Replaced filter. Found supply section of the system full of biological growth. Recommend adding a air purifier to system to clean area and increase air quality in house. Schedule install for Tues 8-10. System should have a inline safety switch installed on drain in attic. System is heating good at this time and running at safe levels.


Jordan R.

Jordan R. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Systems very old and need to be replaced. No water safety on either system. Added 1lb r22 to downstairs system


Reece W.

Reece W. Job Checkin

Found system low on r410a and frozen up. De-iced System. Found leak at king valve. Adjusted valve and replaced cap. Recharged system. System is cooling at this time. Unit has an assured warranty, office needs to contact Goodman to collect payment.


Michael A.

Michael A. Job Checkin

Completed 3 system furnace repair and preventative maintenance check. Main level and basement systems. The main level system for the front of the building was found to have a blower motor which was making a whining noise. Also, the basement heat pump had a burnt and pitted contactor.


Vu T.

Vu T. Job Checkin

Furnace repair. Checked and failed due to cracked ignition and a bad flame sensor. Replaced both parts under extended warranty with labor but no parts. Repaired furnace ignition and flame sensor, system operating at this time. Completed combustion calibration. Sign up 1 Comfort Club Membership and complete heating preventative maintenance check.


Reece W.

Reece W. Job Checkin

Installed 6" supply in the bedroom.


Steve I.

Steve I. Job Checkin

Here are the options to replace the Condenser and Coil. Good option is Standard change-out similar to what you have. Better option is a upgrade efficiency condenser. Going from a 14 seer to a 16 seer. Best option is the 2 stage condenser. Starts at 16 seer full capacity but will increase in efficiency when only in half capacity.


Steve I.

Steve I. Job Checkin

Found leak in the evaporator coil. Will call back tomorrow with options to repair and replace.


Ta K.

Ta K. Job Checkin

2 system a/c repair, preventative maintenance, and Comfort Club Membership renewal. Replaced filters, cleared drains and cleaned a/c coils. Found a rusty coil but did not detect a leak. Added 1 lb to the upstairs system and 7 lbs to the downstairs system with leak a seal. Both systems are charged with 10-degree subcooling per manufacture chart and cooling normally at this time


Steve I.

Steve I. Job Checkin

Found the system out of charge. Discovered a leak at the king valve for the suction line. Tightened valve. Believe this is from the cold weather freezing the gasket and thawing. No other leaks discovered. Checked evaporator coil and line set. Condenser holds 16.75 lbs of 410a. Quotesdd the customer for both the refridgerant as well as the trip and diagnostic charge. The customer wants to discuss reimbursement with warranty company before paying for refrigerant.


Vu T.

Vu T. Job Checkin

Complete 3 a/c preventative maintenance check. Found main system operating with pitted and burnt main electrical switch, weak capacitor and missing additional water protection for the drain line. Find basement new Trane system operating normally. Find guess room system operating normally. Suggest customer repair main system but customer denied repair suggestion at this time. All 3 system cooling at his time but the main system is not reliable.Heating and cooling maintenance complete which will help lower cooling cost for this residential customer. Cooling system is now ready for spring and summer weather.


Ta K.

Ta K. Job Checkin

Heating repair: no heat main floor system zone. Found no signal from the thermostat to the system. Bypass thermostat to test and system came on and shut off. Replaced flame safety sensor and system came on. Thermostat did not send a signal to the furnace to operate. Reset thermostat and now working normally. Suggest replacing the thermostat.


Ta K.

Ta K. Job Checkin

2 system furnace prepaid preventative maintenance service. Replaced filters, checked electrical and safety switches all ok at this time. Both systems need a combustion calibration, to get CO levels within safe range. Both systems heating normally.